Showing 169–192 of 192 results

Show sidebar
Close

Fluke 8270A and 8370A Modular High-Pressure Controllers / Calibrators

  • The 8270A measures and controls pressures from vacuum to 44 MPa (6400 psi).  It can be configured with ranges as low as 100 kPa (15 psi).
  • The 8370A measures and controls pressures from atmosphere to 107 MPa (15 500 psi).  It can be configured with ranges as low as 700 kPa (100 psi).
-10%
Close

Fluke BP7235 Ni-MH Battery Pack, 7.2V, 2500 mA-hour

$501.00
Excluding GST 10%

Fluke BP7235 Offers The Fluke BP7235 is a 7.2V 2500 mA-hour rechargeable Ni-MH battery pack. Provides typical 16-hour battery life

-10%
Close

Fluke BP7240 Battery Pack

$284.00
Excluding GST 10%

Li-Ion battery pack for the 75X Documenting Process Calibrator.

Placeholder
Close

Fluke Constant Volume Valve

The constant volume valve  is used in piston gauge crossfloats and other applications in which two high pressures need to be disconnected and reconnected with minimal purturbations on either side.

Placeholder
Close

Fluke Custom Systems

  • Turn-key pressure calibration rack
  • Portable calibration carts
  • Automated pressure calibration system
Placeholder
Close

Fluke DH400 High Pressure Flex Tubes

  • Lightweight – Tube weight is only 0.5 oz/yd of length (16 g/m).
  • Working Pressure – Up to 6 000 psi (40 MPa).
  • Flexibility – Bending radius of 15/16 in. (2.4 cm) at maximum operating pressure.
  • Temperature – No derating of operating pressure for temperatures from -30 °F to 140 °F, (-34 °C to 60 °C).
  • Weather – Inert to ozone and ultraviolet
  • Safety – Burst pressure of 20,000 psi (140 MPa) for a 3.3 margin with operating pressure.
  • Aging – Negligible humidity absorption
  • Growth – Less than 5% physical change overall at maximum operating pressure
  • Chemical Resistance – Compatible with an extremely wide range of liquid and gas media
Placeholder
Close

Fluke GB Gas Booster

  • Hands free and self regulating package – can be mounted out of the way (under a bench or behind a partition)
  • Two high pressure output ranges:
    – GB-75: pressure up to 10,000 psi(70 MPa)
    – GB-K-152: pressure up 15,000 psi (103 MPa)
Placeholder
Close

Fluke Liquid Trap

  • Working pressure range – 3000 psi (206 bar)
  • Includes convenient drain valve and mounting stand
  • Place between device under test and calibrator
  • 1/4 inch NPT fittings
  • Can be used with any calibrator including Fluke Calibration Series 7215 Controllers, Druck DPI 515 and others
Placeholder
Close

Fluke molbloc-L Laminar Flow Element

  • Useable with existing molbox1+ and molbox RFM mass flow terminals and COMPASS software
  • Integrated filter to protect against contamination
  • Integral gas temperature conditioning and measurement
  • Continuous, real-time reading
  • Can be fully automated
  • No moving parts
Close

Fluke MPG2-H Manually Operated Pressure Generator Controller for Hydraulic Pressure

Economic solution to manually generate and adjust pressure from atmosphere to as high as
200 MPa (30,000 psi)
• Generates large pressure changes quickly and adjusts pressure precisely at a setpoint
• Self-contained design with compact 26 cm x 44 cm (10.2 in. x 17.3 in.) footprint
• Includes two (2) test ports, with standard high pressure gland and collar fittings
• Ideal for working with high pressure

-5%
Placeholder
Close

Fluke Networks GLD3-DSX-8-ADD – 3 Year Gold Support for DSX-8000-ADD

$5,900.00
Excluding GST 10%

Fluke Networks GLD3-DSX-8-ADD 3 Year Gold Support for the DSX-8000-ADD

  • 3 Year Gold Support for the DSX-8000-ADD​
  • One calibration and factory refresh per year at no charge
  • Receive a loaner unit during calibration to eliminate downtime
  • 24/7 technical support will toll-free support number
  • Covers damage to the tester
  • Covers annual traceable calibration, software updates, performance check, refurbishment of worn copper ports and scratched fiber ports
  • Covers replacement of damaged parts and accessories that shipped with the unit
  • Includes Prepaid express freight with labels
Close

Fluke P3000 Pneumatic Deadweight Testers

  • Pressure ranges from vacuum through 2 000 psi (140 bar)
  • Accuracy better than .015 % of reading. (Increased accuracy option of 0.008 %)
  • Gas operated with optional hand pumps
  • Dual vacuum/pressure models available
  • Psi, bar, kgf/cm2, kPa and MPa ranges available
  • Piston/cylinder design provides stability and repeatability
  • Built-in pneumatic hand pumps for pressure and vacuum
  • Piston flotation indicator
  • High quality needle valves provide optimum control
  • Mounted spirit level and adjustable feet
  • Test station design with O-rings eliminates the need for PTFE tape or wrenches
  • Improved case with springloaded latches for hood
  • Sturdy weight box with hinged lid and side handles for easy transport
Close

Fluke P3100 Hydraulic Deadweight Testers

  • Pressure ranges to 20,000 psi (1400 bar)
  • 0.015% of reading accuracy standard (0.008% optional)
  • Single or dual piston formats
  • Built-in hand pumps standard
  • Mounted spirit level with adjustable feet
  • Units can be trimmed to local gravity FOC
Close

Fluke P3200 Hydraulic Deadweight Tester

  • Pressure ranges to 10,000 psi (700 bar)
  • 0.015% of reading accuracy standard (0.008% optional)
  • Single or dual piston formats
  • Built-in hand pumps standard
  • Mounted spirit level with adjustable feet
  • Units can be trimmed to local gravity FOC
Close

Fluke P3800 Hydraulic Deadweight Testers

  • Pressure ranges to 60,000 psi (4000 bar)
  • Select from two accuracy classes; 0.02% or 0.015% of reading
  • Includes hand pump and intensifier for generating high pressures
  • Tungsten carbide piston and cylinder provides long term stability and durability
  • Mass set can be trimmed to local gravity FOC
Placeholder
Close

Fluke P5500 Adapters, Separators and Dirt/Moisture Traps

Fluke Calibration provides the complete solution for pressure calibration using a deadweight tester, including accessories for test media separation, dirt

Close

Fluke PG7000-AMH – Automated Mass Handler for PG7000 Piston Gauges

The AMH system is an optional accessory to PG7000 platforms. It can be added to existing platforms or ordered with new installations. Two models are available to cover the complete PG7000 line of gas and oil operated piston gauges… including absolute mode with a vacuum reference. Thanks to the PG7000’s unique system architecture, the exact level of automation appropriate for the application can be configured with standard components. Automate mass handling while maintaining direct operator control over pressure generation and adjustment, or use standard pressure controllers to automate pressure control and make fully automated piston gauge operation a reality. In all cases, PG7000’s unified approach assures a simple, integrated system with a single local and remote interface.

Close

Fluke PG7601 Piston Gauge

  • State-of-the-art primary pressure standards for the lowest uncertainty levels
  • Unified solution from vacuum to 500 MPa
  • Outputs fully validated reference pressures in real time
  • Intuitive local operator interface
  • Manual, semi-automated and fully automated configurations
Close

Fluke PPC4 Pressure Controller / Calibrator

    • Portable pressure calibrator, rugged enough for mobile applications and standard shipment without special packaging
    • Advanced user interface with full support in 11 languages
    • Covers the absolute range of 1 kPa (0.15 psi) to 14 MPa (2,000 psi) and gauge equivalent, including very low differential pressure
    • Control precision to ± 4 ppm of Q-PRT span, default ± 0.005% of Autoranged range
    • Three different Q-RPT measurement classes available to fit different performance requirements
    • Measured and delivered pressure uncertainties calculated real-time and available on remote and local interfaces
    • Q-RPTs can be located in an external RPM4 so that PPC4 does not need to be shipped or removed for recalibration
    • AutoRange feature optimizes and sets measurement, control and safety features for the specific range of the test beign run with a few simple entries
    • Dynamic and static control modes with default or user specified parameters
    • Common remote command protocol with Fluke Calibration PPC3 pressure controllers
    • RS-232 and front panel USB included standard, IEEE488.2 optional
    • Instantaneous switching between absolute, gauge and bidirectional gauge modes without added hardware or calibration requirements
    • Instantaneous switching between control and measure modes with no pressure discontinuity
    • Automated AutoZeroing while vented at atmospheric pressure
    • 16 SI and US pressure units as well as user definable uits
    • Simple, objective pressure “ready/not ready indicator with user adjustable criteria
    • Automatic pressure head correction
    • On-board, programmable calibration sequences with UUT tolerance testing
    • Automated leak testing routines
    • Valve drivers option for system design
    • Automated self purging liquid trap (SPLT) accessory available for protection against liquid contamination
    • Flash memory for simple and free embedded software upgrades from flukecal.com
    • …and much more
Placeholder
Close

Fluke PPCH Automated Pressure Controller / Calibrator

  • Hydraulic pressure controller to 200 MPa (30,000 psi)
  • High precision control
  • AutoRange feature
  • For liquid pressures up to 30,000 psi (200 MPa)
  • One or two Q-RPTs in each controller
  • Supports external reference pressure transducers
  • FLASH memory for simple and free embedded software upgrades via Fluke Calibration web-site
Placeholder
Close

Fluke RPM4 BA100K Reference Pressure Barometer

  • Transfer standard level measurement uncertainty, ± 0.01 % of reading (± 0.008 % for dual channel mode)
  • Single channel or dual channel with parallel measurementmode to reduce uncertainty and increase reliability
  • Large, easy to read display
  • RS232 and IEEE-488 interfaces included
  • On-board functions including adjustable average time, high/low, deviation from set point, rate, freeze
  • 17025 accredited calibration included in purchase price.
  • Ideal for absolute pressure AutoZeroing of pressure transfer standards and molbox flow terminals
  • Compact and rugged presentation
  • Optional battery pack
Close

Fluke RPM4 Reference Pressure Monitor

  • Independent quartz reference pressure transducer modules (Q-RPTs) with individual self-defense systems (SDS™) (See Q-RPT module advantages under “Features.”)
  • Infinite Ranging and AutoRange™
  • Differential measurement mode (channel 1- channel 2)
  • 15 kPa (2.2 psi) compound gauge Q-RPT with turndown to < 3 kPa (0.4 psi)
  • Integrates with PPC4 as external reference measurement device
  • Battery/charger pack available
  • RPM4 carries on the tradition of the RPM line of pressure monitors: combining very high end performance with ruggedness and reliability
  • Stability based Ready/Not Ready indication
  • Built-in fluid head corrections
  • User defined pressure units
  • Intelligent AutoZero™ function
  • Remote [ENTER] switch
  • Large character, easy to read display
  • 12 V dc power and battery pack option
  • External valve drivers
  • RS232 and IEEE-488 communications
  • PC based recalibration utility software included
  • Flash memory for simple and free embedded
Close

Fluke RPM4-AD Reference Pressure Monitor

Covers the absolute and differential pressure ranges of typical air data instruments.
• Fixed wing and rotary wing range versions
• True Pt, Ps, Qc operation
• Transfer standard level measurement uncertainty
• Automated rate measurement with user specified sample time
• Automated leak check function
• Compact and rugged presentation
• SDS self defense system shuts off test ports to protect from overpressure
• RS232 and IEEE-488 interfaces included
• Battery pack available
• Ideal for validation of air data test sets (ADTS)

Placeholder
Close

Fluke SPLT Self Purging Liquid Trap

The SPLT is made up of a stainless steel body with an internal X-Type coalescing filter and a bottom drain port fitting with an electrically actuated purge valve.  The filter and valve assembly is installed in a mounting stand.

The SPLT is intended to collect and exhaust liquid contaminants that may be present in the device or system under test so that they do NOT return to the PPC.