Showing 37–70 of 70 results

Show sidebar
Close

Fluke 7060/7080 Really Cold Temperature Calibration Baths

Chill to –40, –60, or –80 °C without external coolants

  • Self-contained refrigeration—no LN2 or chiller required
  • Temperatures as low as –80 °C in real metrology baths
  • Best stability and uniformity available at –80 °C and below
  • Large working areas for increased throughput
Close

Fluke 7196B LN₂ Comparison Calibrator

  • Low-cost calibrations to –196°C
  • Simple to use
  • Uncertainty less than 2 mK
Close

Fluke 7312 Triple Point of Water Maintenance Bath

  • Maintains TPW cells for up to six weeks
  • Optional immersion freezer for simple cell freezing
  • Independent cutout circuit protects cells from breaking
Close

Fluke 742A Resistance Standards

  • Small and rugged resistance calibrators
  • No oil or air baths required
  • 18° to 28° C operating range
  • Six-month stability to 2.5 ppm
  • Supplied with temperature characterization
Close

Fluke 7900 Controller for Rosemount-Designed Baths

  • All the features of the Fluke Calibration 2100 Controller
  • Installs easily
  • Two independent over-temperature cutout circuits
Placeholder
Close

Fluke 7911A2 Constant Temperature Ice Bath

  • Lower uncertainty zero-point (to ± 0.002 °C uniformity)
  • Affordable—amazing price for this uniformity and stability
  • Many probes can be checked/calibrated at once
-3%
Close

Fluke 9009 – Dual Range Dry-Block Calibrator, Black

$9,599.00
Excluding GST 10%

Fluke 9009 Dual Range Dry-Block Calibrator Offers

Features

  • Two independently controlled temperature blocks, one for heating and one for cooling with a combined range of -15 to 350°C
  • Unique dual unit allows you to calibrate your sensor in the heated well while the cool well stabilizes; this eliminates the need to wait for multiple temperature points during calibration
  • Hot block provides temperatures from 50 to 350°C (122 to 662°F), while the cold block covers the range of -15 to 110°C (5 to 230°F)
  • Each block is controlled by a precision Hart Scientific temperature controller
  • Cold block is calibrated to within ±0.2°C with stability of ±0.05°C
  • Hot block’s display is accurate to ±0.6°C with stability of ±0.05°C
  • NIST-traceable calibration is included for each of the two test blocks
  • Each temperature block includes two wells with removable inserts; calibrate four probes at once, or calibrate two probes at the same time with an external reference, or use the two temperature wells to get quick “zero” and “span” references for transmitter calibrations
Close

Fluke 9009 Industrial Dual-Block Thermometer Calibrator

  • Temperatures from –15 °C to 350 °C in one unit
  • Two wells in each block for simultaneous comparison calibrations
  • Rugged, lightweight, water-resistant enclosure
Close

Fluke 9011 High-Accuracy Dual-Well Calibrator

  • Combined range from –30 °C to 670 °C, one unit – two blocks
  • Two independent temperature controllers (hot and cold side)
  • Stability to ±0.02 °C
  • Multi-hole wells for calibrating up to eight probes simultaneously
-3%
Close

Fluke 9100S – Dry Block Calibrator

$3,259.00
Excluding GST 10%

Features

  • Compact design
  • Ranges from 95 to 707°F (35 to 375°C)
  • Accuracy to ±0.25°C, stability of ±0.25°C at 122°F (50°C)
  • RS-232 interface with 9930 Interface-it v3.81 software (Optional )
Close

Fluke 9100S, 9102S Handheld Dry-Wells

  • Smallest dry-wells in the world
  • Ranges from –10°C to 375°C
  • Accuracy to ±0.25°C, stability of ±0.05°C at 0°C
  • RS-232 interface
Close

Fluke 9101 Zero-Point Dry-Well

  • Bath-quality stability in a portable ice-point reference
  • Easy re-calibration for long-term reliability
  • Ready-light frees user’s time and attention
  • Solid-state cooling technology
-2%
Close

Fluke 9102S-256 Low Temperature Dry Block Calibrator

$5,399.00
Excluding GST 10%

Features

  • For work in the temperature range of -10 to 122°C
  • Stable to ±0.05°C
  • Includes a NIST-traceable calibration
  • Excellent for dial gauges, digital thermometers, bulb switches, and other sensors that need calibration below ambient
  • Two wells so you can use one for a reference thermometer to increase accuracy.
  • Both wells are 1/2″ in diameter, and each has inserts available for almost any sensor size
  • Battery pack option that gives you approximately four hours of field use when AC power is unavailable
  • Removable insert sleeves 1/2″ O.D. x 4″ deep (13 mm x 102mm) and comes complete with 1/4″ and 3/16″ inserts (order additional insert sizes as needed)
-4%
Close

Fluke 9103 – Low Temperature Field Drywell

$5,999.00
Excluding GST 10%

Fluke 9103 Offers

Features

  • Lightweight and very portable
  • Accuracy to ±0.25°C
  • Easy to recalibrate
Close

Fluke 9103, 9140 Dry-Well Calibrators & Dry Block Calibrators

  • Lightweight and very portable
  • Accuracy to ±0.25 °C
  • RS-232 interface
  • Easy to recalibrate
Close

Fluke 9114, 9115A, 9116A Freeze-point furnaces

  • Designed to extend plateaus
  • High-stability OEM controllers, RS-232 included
  • External cooling coils
Close

Fluke 9117 Annealing Furnace

  • Guards against contamination
  • Anneals both SPRTs and HTPRTs
  • Fully programmable
Close

Fluke 9118A Thermocouple Calibration Furnace

  • Tube furnace configuration (without isothermal block): Base-metal thermocouples are often sheathed in formable materials such as braided fiberglass or PTFE. During calibration, they are bundled around a reference thermometer, held together with fiberglass cord or tape, and inserted into a tube furnace.
  • Isothermal block configuration: Metal- or ceramic-sheathed thermocouples are generally constructed with noble-metal thermoelements and therefore have higher calibration accuracy requirements. The isothermal block, which accommodates up to four 6.35 millimeter probes, improves heat transfer and temperature stability. This better equalizes the temperature between the reference probe and the UUT, which lowers measurement uncertainty compared to calibration without a block.
-7%
Close

Fluke 9132 – Portable Infrared Calibrator 50C to 500C

$7,500.00
Excluding GST 10%
  • Certify IR pyrometers from –30 °C to 500 °C (–22 °F to 932 °F)
  • Large 57 mm (2.25 in) blackbody target
  • RTD reference well for contact temperature measurement
  • Small, compact design in a blackbody calibrator
-4%
Close

Fluke 9142 – Field Metrology Wells

$9,999.00
Excluding GST 10%

Key Features: 

  • Lightweight, portable, and fast
  • Cool to –25 °C in 15 minutes and heat to 660°C in 15 minutes
  • Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
  • True reference thermometry with accuracy to ±0.01 °C
  • On-board automation and documentation
  • Metrology performance in accuracy, stability, uniformity, and loading

 

Close

Fluke 9142, 9143, 9144 Field Metrology Wells

  • Lightweight, portable, and fast
  • Cool to –25 °C in 15 minutes and heat to 660°C in 15 minutes
  • Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
  • True reference thermometry with accuracy to ±0.01 °C
  • On-board automation and documentation
  • Metrology performance in accuracy, stability, uniformity, and loading
-2%
Close

Fluke 9143 – Mid Temperature Field Drywell

$7,999.00
Excluding GST 10%

Key features

  • Lightweight, portable, and fast
  • Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
  • True reference thermometry with accuracy to ±0.01 °C
  • On-board automation and documentation
  • Metrology performance in accuracy, stability, uniformity, and loading
-3%
Close

Fluke 9144 – High Temperature Field Drywell

$8,499.00
Excluding GST 10%

Key features

  • Lightweight, portable, and fast
  • Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
  • True reference thermometry with accuracy to ±0.01 °C
  • On-board automation and documentation
  • Metrology performance in accuracy, stability, uniformity, and loading
Close

Fluke 9150 Thermocouple Furnace

    • Temperature range to 2192°F (1200°C) with a stability of ±0.5°C, and display accuracy of ±5°C across its entire range
    • Uses Hart’s microprocessor-based controller for great stability and set-point accuracy
    • Rapid cool-down and heat-up times
    • Interchangeable multiple hole probe sleeves
    • Eight set-point memory
    • Adjustable readout in °C or °F
    • RS-232 port for connection to a PC
Close

Fluke 9170, 9171, 9172, & 9173 Metrology Well Calibrators

  • Best-performing industrial heat sources (accuracy, stability, uniformity) in the world
  • Immersion depth to 203 mm (8 in)
  • Optional ITS-90 reference input reads PRTs to ±0.006 °C
  • Temperature range from –45 °C to 700 °C
Close

Fluke 9190A Ultra-Cool Field Metrology Well

Wide temperature range

–95 °C to 140 °C

Excellent accuracy

Accuracy using built-in reference thermometer readout:  ± 0.05 °C full range

Display accuracy:  ± 0.2 °C full range

Best-in-class stability

± 0.015 °C full range

Fast cooling time

23 °C to –90 °C:  80 minutes

23 °C to –95 °C:  90 minutes

140 °C to 23 °C:  60 minutes

Close

Fluke 9210 Mini Triple Point of Water Maintenance Apparatus

  • Easy preprogrammed realization
  • Inexpensive fixed-point solution
  • Training takes a few hours
Close

Fluke 9230 Gallium Cell Maintenance Apparatus

  • One week plateau duration
  • No hassle automatic realizations
  • Used daily in our Primary Lab
Close

Fluke 9260 Mini Fixed-Point Cell Furnace

  • Good introduction to fixed-point calibration
  • User friendly and inexpensive
Placeholder
Close

Fluke Calibration Bath Fluids

  • Thermal characteristics
  • Lifetime
  • Change in characteristics due to temperature cycling
  • Absorption of water from the air
  • Vaporization—fumes and fume hood requirements
  • Expansion due to heat
  • Contamination—mixing oils or introducing contamination with unclean probes
  • Conductivity properties
  • Effects of using fluids outside of their range—fire, explosion, polymerization
  • Effects of altitude on boiling point
Placeholder
Close

Fluke Custom Temperature Calibration Baths

Our engineers and designers know more about temperature calibration baths than anyone else. You’ll find our baths throughout the best national and international temperature calibration labs. It does not matter what type of calibration application you have – oceanography, missile optics, infrared, sensor manufacturing, semiconductor, renewable energy, LIG manufacturing, or down-hole tools. We have probably already built baths to do the job.

Close

Fluke ITS-90 Fixed-Point Cells

  • Best cell uncertainties commercially available
  • Every ITS-90 fixed point available from argon to copper
  • Plateaus last days (gallium for weeks and TPW for months)
  • Manufactured and tested by Fluke Calibration’s primary standards scientists
Placeholder
Close

Fluke Mini Fixed-Point Cells

  • Lower uncertainties than comparison calibrations
  • All ITS-90 fixed points from TPW to copper
  • Reduced equipment and annual recalibration costs
Placeholder
Close

Fluke Probe Support Hardware

  • 2 V-bases
  • 1 29-inch stainless steel rod
  • 2 23-inch rods
  • 5 bossheads
  • 2 micro-clamps
  • 1 medium clamp