CIQ-100 – Fluke Networks CableIQ™ Qualification Tester

Original price was: $3,624.00.Current price is: $3,262.00.
Excluding GST 10%

Key features

Copper qualification tester troubleshoots and qualifies Ethernet network cabling speed (10/100/1000/VoIP)

  • Works on live networks to provide Ethernet switch detection and device configuration
  • Measure network capacity (10 Meg, 100 Meg, 1 Gig) to determine support for VoIP, data and video
  • Advanced troubleshooting diagnostics; insertion loss, cross talk, noise issues
  • Core troubleshooting features; length, distance to fault, graphical wire mapping, opens, shorts, power over Ethernet (POE) detection
  • Tests all copper cabling media: twisted-pair, coax, and audio
-10%
Close

MS2-KIT – Fluke Networks MicroScanner2 Professional Kit

Original price was: $2,044.00.Current price is: $1,840.00.
Excluding GST 10%

Key features

  • Revolutionary Interface – Graphical wiremap, length, cable ID, and distance to fault displayed on one screen
  • Multimedia Support – tests all common media types including RJ11, RJ45, Coax, with no need for adapters
  • IntelliTone Toning – trace virtually any cable or wire pair with IntelliTone digital and analog toning
  • VDV Service Detection – verifies today’s media services, including 10/100/1000 Ethernet, POTS, & PoE
  • Rugged Housing – Integrated rubber holster enhances grip and makes it durable enough for the toughest jobs
  • Oversized Display – Large, backlit LCD makes results crystal clear whether in bright sunshine or in a dark closet
-10%
Close

Fluke MS2-100 – Micro-Scanner 2 Cable Verifier Tester

Original price was: $1,231.00.Current price is: $1,108.00.
Excluding GST 10%

Key features

  • Revolutionary Interface – Graphical wiremap, length, cable ID, and distance to fault displayed on one screen
  • Multimedia Support – tests all common media types including RJ11, RJ45, Coax, with no need for adapters
  • IntelliTone Toning – trace virtually any cable or wire pair with IntelliTone digital and analog toning (Sold separately or included in MS2-KIT)
  • VDV Service Detection – verifies today’s media services, including 10/100/1000 Ethernet, POTS, & PoE
  • Rugged Housing – Integrated rubber holster enhances grip and makes it durable enough for the toughest jobs
  • Oversized Display – Large, backlit LCD makes results crystal clear whether in bright sunshine or in a dark closet

Fluke Networks PRO3000 Tone Generator and Probe Kit

Original price was: $260.00.Current price is: $219.00.
Excluding GST 10%

Key features

  • Send tone signal up to 10 miles (16 km) on most cables
  • Analog tone generator with bed-of-nails clips, unfiltered probe
  • SmartTone™ provides 5 distinct tones for exact pair identification
  • Continuity testing and line polarity confirmation
  • Ergonomic sleek design, 3.5 mm headphone jack
Close

Fluke 9150 Thermocouple Furnace

    • Temperature range to 2192°F (1200°C) with a stability of ±0.5°C, and display accuracy of ±5°C across its entire range
    • Uses Hart’s microprocessor-based controller for great stability and set-point accuracy
    • Rapid cool-down and heat-up times
    • Interchangeable multiple hole probe sleeves
    • Eight set-point memory
    • Adjustable readout in °C or °F
    • RS-232 port for connection to a PC
Close

Fluke 9118A Thermocouple Calibration Furnace

  • Tube furnace configuration (without isothermal block): Base-metal thermocouples are often sheathed in formable materials such as braided fiberglass or PTFE. During calibration, they are bundled around a reference thermometer, held together with fiberglass cord or tape, and inserted into a tube furnace.
  • Isothermal block configuration: Metal- or ceramic-sheathed thermocouples are generally constructed with noble-metal thermoelements and therefore have higher calibration accuracy requirements. The isothermal block, which accommodates up to four 6.35 millimeter probes, improves heat transfer and temperature stability. This better equalizes the temperature between the reference probe and the UUT, which lowers measurement uncertainty compared to calibration without a block.
Close

Fluke 9103, 9140 Dry-Well Calibrators & Dry Block Calibrators

  • Lightweight and very portable
  • Accuracy to ±0.25 °C
  • RS-232 interface
  • Easy to recalibrate
Close

Fluke 9101 Zero-Point Dry-Well

  • Bath-quality stability in a portable ice-point reference
  • Easy re-calibration for long-term reliability
  • Ready-light frees user’s time and attention
  • Solid-state cooling technology
Close

Fluke 9011 High-Accuracy Dual-Well Calibrator

  • Combined range from –30 °C to 670 °C, one unit – two blocks
  • Two independent temperature controllers (hot and cold side)
  • Stability to ±0.02 °C
  • Multi-hole wells for calibrating up to eight probes simultaneously
Close

Fluke 9009 Industrial Dual-Block Thermometer Calibrator

  • Temperatures from –15 °C to 350 °C in one unit
  • Two wells in each block for simultaneous comparison calibrations
  • Rugged, lightweight, water-resistant enclosure
Close

Fluke 700HPPK Pneumatic Test Pump Kit

  • Generate and adjust pneumatic pressures up to 21 MPa (3000 psi)
  • Rugged, portable and stable enough to go anywhere — on any surface
  • Reaches pressure in 20 seconds to full scale into a 30 cm3 volume
  • Detachable pressure adjustment system for adjusting pressure, connecting reference and test devices on bench and in the field, and isolating and venting pressure
  • Easily switch out reference gauges without requiring PTFE tape or tools
  • 2-meter (6.5-foot) pressure line and assorted pressure fittings enable a wide variety of possible connections
  • In-line filter and desiccant systems protect device from contamination from the DUT
Placeholder
Close

Fluke 6531, 6532 E-DWT Electronic Deadweight Tester Kits

  • No weights to load and unload, transport or send out for calibration
  • Provides real-time pressure indication with no need to know and correct for local gravity or ambient temperature
  • No piston-cylinder changes
  • No significant sensitivity to level or vibration
  • Able to set and read any pressure value exactly, no minimum increment limited by smallest available masses; perfect for applications that require setting a nominal pressure precisely on the device under test and measuring it, such as analog gauge calibration
  • Operates in any unit of measure, switching easily from one unit to the next