Showing 1261–1272 of 2392 results

Show sidebar
Close

Fluke 5640 Series Thermistor Standards Probes

  • Accuracy to ± 0.001 °C
  • Affordable system accuracy to ± 0.004 °C or better
  • NIST-traceable calibration included from manufacturer; accredited calibration from Fluke Calibration optional
Close

Fluke 5627A Precision Thermometer, RTD Temperature Probe

  • Vibration and shock resistant
  • NVLAP-accredited calibration included, lab code 200706-0
Close

Fluke 5626, 5628 Secondary Standard PRTs

  • Range to 661°C
  • Meets all ITS-90 requirements for resistance ratios
  • Rtp drift < 20 mK after 500 hours at 661°C
  • Calibrated accuracy of ± 0.006 °C at 0 °C
Close

Fluke 5624 Platinum Resistance Thermometer to 1000 °C

  • Temperature range of 0°C to 1000°C
  • Accuracy (includes short-term stability and calibration uncertainty) of ±0.05°C to 962°C
  • Long-term drift of 0.01°C at 0°C after 100 hours at 1000°C
  • Designed by Fluke Calibration’s primary standards design team
Placeholder
Close

Fluke 5623B Precision RTD Freezer Probe

  • Fully immersible probe assembly to –100°C
  • NVLAP-accredited calibration, lab code 200706-0, and ITS-90 coefficients included
  • Accuracy to ±0.05°C over the full range
Placeholder
Close

Fluke 5622 Fast Response Platinum Resistance Thermometers (PRTs)

  • Time constants as fast as 0.4 seconds
  • NVLAP-accredited calibration, lab code 200348-0
  • Small probe diameters ranging from 0.5 mm to 3.2 mm
Close

Fluke 5618B Small Diameter Industrial RTD

  • Small diameter sheath, 3.2mm (0.125 in)
  • Excellent stability
  • Includes ITS-90 coefficients
  • NVLAP-accredited calibrated from –200°C to 500°C, lab code 200706-0
Close

Fluke 5615 Secondary Reference Temperature Standards

  • Affordable wide-range accuracy
  • Calibrated accuracy ± 0.012 °C at 0 °C
  • Reference-grade platinum sensing element
  • NVLAP-accredited calibration included, lab code 200706-0
Close

Fluke 5610, 5611, 5611T, 5665 Temperature Probes, Reference Thermistor Probes

  • Temperature probes with short-term accuracy to ± 0.01 °C; one-year drift < ± 0.01 °C
  • Accredited NVLAP calibration optional
  • Flexible PTFE and silicone coated fast-response models
  • Rugged polished stainless steel sheaths
Close

Fluke 5606 Full Immersion PRT

  • 5606: -200 °C to 160 °C
  • Calibration accuracy of ± 0.05 °C
  • Transition junction and lead wires can withstand full PRT temperature range
  • Unique probe seal of 5606 prevents ingress of moisture
  • NVLAP-accredited calibration
Close

Fluke 3990 Manual Pressure Control Packs

  • Self-contained for ease-of-use
  • Includes precision adjustor to allow increments as fine as 0.00025 psi
  • 1000 and 3000 psi models also provide absolute and negative gauge mode
  • Includes metering valve for fine control
  • Vent valve provides easy means to vent pressure to atmosphere
  • Convenient 1/4 inch NPT connections
Close

Fluke 3130 Portable Pressure Calibrator

  • Measure and generate pressures from vacuum to 2 MPa (300 psi, 20 bar)
  • Internal pump can generate vacuum to -80 kPa (-12 psi, -0.8 bar) or pressure to 2 MPa (300 psi, 20 bar)
  • Supply pressure connection allowing the use of external gas supply up to 2 MPa (300 psi, 20 bar)
  • Includes variable volume for fine adjustment of pressures
  • Pressure measurement accuracy of ± (0.025 % reading + 0.01 % FS)
  • Electrical measurement and 24 volt supply for close looped calibrations
  • Measure or generate 4 to 20 mA
  • Measure 0 to 30 V dc
  • Powered by internal, high capacity, NiMH battery or universal ac mains adapter
  • Compatible with Fluke 700P and 750P Pressure Modules