Fluke 5699 High-Temperature Metal-Sheath SPRT

  • Range to aluminum point (660 °C )
  • Inconel™ and platinum sheaths guard against contamination
  • Less than 8 mK/year drift
  • Many calibration options available including by fixed point
  • Fifth wire provides shield ground
Close

Fluke 5698-25 Working Standard SPRT

  • Conforms to ITS-90 SPRT guidelines
  • Drift rate typically 0.003 °C
  • Calibration options by fixed point
  • Unmatched performance-to-price-ratio
Close

Fluke 5686-B Glass Capsule SPRT

  • Temperatures from –260 °C (13 K) to 232 °C
  • Stability typically 0.001 °C over 100 °C range
  • Miniature capsule package eliminates stem conduction
Close

Fluke 5681, 5683, 5684, and 5685 Quartz-Sheath SPRTs

  • Drift rates as low as 0.0005 K
  • Proprietary gas mixture ensures high stability
  • Most experienced SPRT design team in the business
Placeholder
Close

Fluke Mini Fixed-Point Cells

  • Lower uncertainties than comparison calibrations
  • All ITS-90 fixed points from TPW to copper
  • Reduced equipment and annual recalibration costs
Close

Fluke ITS-90 Fixed-Point Cells

  • Best cell uncertainties commercially available
  • Every ITS-90 fixed point available from argon to copper
  • Plateaus last days (gallium for weeks and TPW for months)
  • Manufactured and tested by Fluke Calibration’s primary standards scientists
Placeholder
Close

Fluke 5960A Triple Point of Argon System

  • Low uncertainty of 0.25 mK
  • Temperature plateau duration longer than 30 hours
  • Four entrant wells with radial uniformity less than 0.05 mK
  • 480 mm total immersion depth
  • Argon purity of 99.9999 %
  • Multi-language display support
Close

Fluke 5901 Triple Point of Water Cells

  • Easy-to-use, inexpensive standard with uncertainty better than ± 0.0001 °C
  • Four sizes and two shells (glass and quartz) to choose from
  • Isotopic composition of Vienna Standard Mean Ocean Water
Placeholder
Close

Fluke 9600FLT 1 GHz Wide Offset Phase Noise Filter

Use the Filter only at 1 GHz. It rejects phase noise at offsets greater than 1 MHz from the 1 GHz carrier (both sidebands are rejected). Use the filter only when the phase noise specification of the 96xx RF Reference Source is not considered sufficient for the target workload. Only the highest performance spectrum analyzers are likely to require the filter. The filter connects in series with the umbilical lead of the 9640A-50 or 9640A-75 Leveling Head. Use the supplied mounting kit to conveniently attach the filter to the front left handle of the Reference Source. This mount is fully compatible with the Y9600 Rack Mount accessory.

Close

Fluke 96270A 27 GHz Low Phase Noise Reference Source

  • “Self-characterization” lets you avoid calculating correction factors for each component in the signal delivery system
  • “What you set is what you get” accurate signal delivery direct to the UUT input up to 27 GHz
  • Covers a broad range of RF calibration workload
  • Reduces the number of instruments and interconnections required for your RF calibration system
  • Integrated 300 MHz frequency counter and dual power meter readout eliminate need for additional instruments
  • Calibration-specific interface simplifies technician tasks
  • Simplifies uncertainty calculations
  • Lowers RF system maintenance costs
  • With automation, reduces spectrum analyzer calibration times by as much as 50 % over manual methods
Close

Fluke 96040A Low Phase Noise Reference Source

  • Covers a broad range of RF calibration workload
  • Reduces the number of instruments and interconnections required for your RF calibration system
  • “What you set is what you get” accurate signal delivery direct to the DUT input
  • Integrated 50 MHz frequency counter eliminates need for an additional instrument • Calibration-specific interface simplifies technician tasks
  • Simplifies uncertainty calculations by delivering known signals direct to the device under test (DUT)
  • Lowers RF system maintenance costs
  • With automation, reduces spectrum analyzer calibration times by as much as 50% over manual methods
Placeholder
Close

Fluke MET/TEAM® Test Equipment Asset Management Software

  • Manage all aspects of your calibration operation with one paperless solution
  • Improve productivity and reduce operating costs
  • Maintain compliance with regulatory standards
  • Configure and customize for your business rules
  • Report to meet a wide range of requirements
  • Schedule maintenance events
  • Perform batch receiving
  • Create, track and close work orders
  • Track assets as they move through the lab
  • Create and print calibration reports
  • Maintain an audit trail
  • Manage shipping information
  • Track customer and vendor information
  • View business statuses
  • Create data templates and store procedures
  • …and much more