Fluke 5725A Amplifier

  • Frequency limits at higher voltage increase to 100 kHz at 750 V, 30 kHz at 1100 V
  • Load limits are to 70 mA for frequencies above 5 kHz, and to 50 mA for frequencies less than 5 kHz
  • Capacitive load limits are increased to 1000 pF
Close

Fluke 5730A High Performance Multifunction Calibrator

  • Improved performance specifications for ac voltage, ac current and resistance
  • 6.5 inch VGA capacitive touch screen with full color graphical user interface
  • Visual Connection Management™ output terminals guide connections
  • Graphical user interface in nine languages
  • Compatible with 52120A and 5725A amplifiers
  • Full MET/CAL® compatibility with 5700A and 5720A procedures
  • Artifact Calibration using 10 V, 1 Ω and 10 kΩ external standards; 30 MHz and 50 MHz wideband output options available
Close

Fluke 5790B AC Measurement Standard

The 5790B covers an alternating voltage range of 600 μV to 1000 V, and a frequency range of 10 Hz to 1 MHz. Wideband voltage options extend frequency range to 30 or 50 MHz.

The 5790B in combination with the Fluke A40B Current Shunts now allow you to make direct, absolute or relative current measurements without the need to perform any calculations

Close

Fluke 6105A, 6100B Electrical Power Quality Calibrator

Wide workload coverage
The 6105A and 6100B cover a wide workload of electrical power test instruments, including:

  • AC voltmeters
  • AC ammeters
  • Current transformers
  • Flicker meters
  • Phase angle meters
  • Power factor meters
  • Power analyzers
  • Power recorders
  • Power transducers-relay testers
  • VA meters
  • VAR meters
  • Voltage transformers
  • Wattmeters (3- or 4-wire)
  • Watthour meters
  • and more
Close

Fluke 6135A/PMUCAL Phasor Measurement Unit Calibration System

The 6135A/PMUCAL system enables you to:

  • Calibrate and test a PMU from a client PC, either at the site of the test system or remotely over the Internet
  • Quickly set up a PMU test
  • Speed through automated calibration procedures or interactively do custom PMU testing
  • Provide the required static and dynamic voltage and current conditions that occur in a power distribution grid specified by the standard
  • Apply those signals to a phasor measurement unit
  • Capture the PMU’s reported results
  • Evaluate the total vector error (TVE), frequency error (FE), and rate of change of frequency error (RFE)
  • Compare those results with the original stimulus
  • Evaluate against the thresholds defined in IEEE Std C37.118.1a™-2014
  • Create test reports, graphs and calibration certificates that can be readily printed or shared electronically
Placeholder
Close

Fluke 720A Kelvin-Varley Divider (Copy)

 

  • 0.1 ppm resolution, seven decades
  • 0.1 ppm of input absolute linearity
  • Built-in self calibration bridge
  • Front panel self-calibration
Close

Fluke 732C and 734C DC Voltage Reference Standards

The simple way to maintain and disseminate the volt

The Fluke Calibration 732C DC Voltage Reference Standard is a RoHS compliant direct voltage reference used to maintain the volt in primary and secondary standards laboratories. Individual 732C voltage standards provide 10 V, 1 V, and 0.1 V outputs and may be transported easily to remote locations while the dc reference is maintained in the laboratory. The 734C DC Voltage Reference Standard consists of four electrically and mechanically independent 732C DC Reference Standards and a rack-width enclosure. Two model families, Base and Select, differ in that the Select models are two times more stable than the Base models.

Because each 732C in the 734C DC Reference Standard is based on the same architecture pioneered in the popular 732A DC Voltage Standard—the first standards lab quality 10 V electronic reference—you can rely on it to provide the same high stability and predictable drift rate you’ve come to expect, in a smaller, more portable package identical to the 732B DC Voltage Standard. The 734C is also compatible with 732B DC standards and can support any combination of 732 B and C models. Similarly, 734A can be used with the newer 732C voltage standards, providing the ultimate flexibility and maximizing asset utilization.

To simplify support of your 734C, Fluke Calibration offers a variety of calibration services to assign values and predicted performance for each of the 10 V outputs, traceable to national standards and to the Fluke Calibration 10 V Josephson Array.

Close

Fluke 7526A Precision Process Calibrator

  • Sources and measures dc voltage, current, resistance, RTDs and thermocouples
  • Extend pressure measurement range with any Fluke 750P and 700P Series Pressure Modules
  • Includes 24 V dc transmitter loop power supply
  • Measures 4-20 mA loop current
  • Includes automated switch-test function
  • Accepts ITS-90 coefficients for accurate SPRT measurements
  • Compatible with MET/CAL® Calibration Software
  • Includes certificate of calibration traceable to national standards (optional A2LA accredited calibration available upon request)
Close

Fluke 752A Reference Divider

  • 10:1 and 100:1 divider outputs
  • Output uncertainty 0.2 ppm and 0.5 ppm
  • Built-in calibration bridge
  • Dynamic Resistor Matching™
  • System switching for ease of use
  • Operating modes