Fluke 721-1603 Dual Sensor Pressure Calibrator
Features
- Two isolated, stainless steel, pressure sensors with 0.025% f.s. accuracy
- Can be configured by selecting either a 16 psig (1.1 bar) or 36 psig (2.48 bar) low pressure sensor and then adding your choice of 7 high pressure ranges
- External pressure module connection supports all pressure modules (29 ranges) for even more measurement capability
- Temperature-compensation ensures accuracy in field applications
- Pt100 RTD input for temperature measurement, accurate to 0.1°C (0.2°F) (Requires optional RTD probe sold separately)
- Measure 4-20 mA signals
- Internal 24 V Loop Power Supply can power a transmitter under test
- Measure up to 30 V DC
- Large graphic style LCD with backlight can be configured to display up to 3 inputs simultaneously (i.e. pressure 1, pressure 2, and RTD or any combination of inputs)
- Pressure displayed in the user’s choice of 19 engineering units
- Switch test on both pressure inputs, or external pressure module
- Operating mode layers support simple measurements to complex applications
- Up to five frequently used setups can be stored; last setup automatically recalled on power-up
- % error and damping functions
Fluke 721-1601 Dual Sensor Pressure Calibrator
Features
- Two isolated, stainless steel, pressure sensors with 0.025% f.s. accuracy
- Can be configured by selecting either a 16 psig (1.1 bar) or 36 psig (2.48 bar) low pressure sensor and then adding your choice of 7 high pressure ranges
- External pressure module connection supports all pressure modules (29 ranges) for even more measurement capability
- Temperature-compensation ensures accuracy in field applications
- Pt100 RTD input for temperature measurement, accurate to 0.1°C (0.2°F) (Requires optional RTD probe sold separately)
- Measure 4-20 mA signals
- Internal 24 V Loop Power Supply can power a transmitter under test
- Measure up to 30 V DC
- Large graphic style LCD with backlight can be configured to display up to 3 inputs simultaneously (i.e. pressure 1, pressure 2, and RTD or any combination of inputs)
- Pressure displayed in the user’s choice of 19 engineering units
- Switch test on both pressure inputs, or external pressure module
- Operating mode layers support simple measurements to complex applications
- Up to five frequently used setups can be stored; last setup automatically recalled on power-up
- % error and damping functions
Fluke 718-1G Pressure Calibrator, -1 to 1 PSI
Features
- Error % calculation for quicker pass/fail decision making in the field
- Best in class mA accuracy of 0.015 % for better measurement confidence and workload coverage
- Min/Max/Hold to capture changing measurements
- Switch test feature for quicker and more accurate pressure switch testing
- New 1 and 300 PSI pressure ranges mean fewer extra tools required
- 1, 30, 100 & 300 PSI ranges now available
- Note: Dry air, non-corrosives only
Applications
- Petro-Chemical
- Oil and Gas
- Pharmaceutical
- Water and wastewater
- Food and Beverage
- Power Generation
Fluke 718-30US Pressure Calibrator with Pressure Vacuum Pump, -12 to 30 PSI
Features
- Error % calculation for quicker pass/fail decision making in the field
- Best in class mA accuracy of 0.015 % for better measurement confidence and workload coverage
- Min/Max/Hold to capture changing measurements
- Switch test feature for quicker and more accurate pressure switch testing
- New 1 and 300 PSI pressure ranges mean fewer extra tools required
- 1, 30, 100 & 300 PSI ranges now available
Applications
- Pressure Instrument Calibration
- Pressure Instrument Maintenance
- Petro-Chemical
- Oil and Gas
- Pharmaceutical
- Water and Wastewater
- Food and Beverage
- Power Generation
Fluke 718-100US Pressure Calibrator with Pressure Vacuum Pump, -12 to 100 PSI
Features
- Error % calculation for quicker pass/fail decision making in the field
- Best in class mA accuracy of 0.015 % for better measurement confidence and workload coverage
- Min/Max/Hold to capture changing measurements
- Switch test feature for quicker and more accurate pressure switch testing
- New 1 and 300 PSI pressure ranges mean fewer extra tools required
- 1, 30, 100 & 300 PSI ranges now available
Applications
- Pressure Instrument Calibration
- Pressure Instrument Maintenance
- Petro-Chemical
- Oil and Gas
- Pharmaceutical
- Water and Wastewater
- Food and Beverage
- Power Generation
Fluke 718-300G Pressure Calibrator, 12 PSI to 300 PSI
Features
- Error % calculation for quicker pass/fail decision making in the field
- Best in class mA accuracy of 0.015 % for better measurement confidence and workload coverage
- Min/Max/Hold to capture changing measurements
- Switch test feature for quicker and more accurate pressure switch testing
- New 1 and 300 PSI pressure ranges mean fewer extra tools required
- 1, 30, 100 & 300 PSI ranges now available
Applications
- Petro-Chemical
- Oil and Gas
- Food and Beverage
- Pharmaceutical
- Test and Measurement
- Instrumentation
Fluke 721EX-3610 Dual Sensor Pressure Calibrator, 36 PSIG/1000 PSIG
Features
- Can be configured by selecting either a 16 psi (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then add any of 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar)
- Two isolated, stainless steel, pressure sensors with 0.025% accuracy
- Switch test on both pressure inputs
- Pressure displayed in the user’s choice of 19 engineering units: psi, bar, mbar, kPa, kgcm2, cmH2O @ 4°C, cmH2O @ 20°C, mH2O @ 4°C, mH2O @ 20°C, inH2O @ 4°C, inH2O @ 20°C, inH2O @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH2O @ 4°C, ftH2O @ 20°C, ftH2O @ 60°F
- Precision temperature measurement with optional RTD probe
- Measures 4 to 20 mA signals
- Large backlit graphic display shows up to three inputs simultaneously
- Store five instrument setups for recall and use
Fluke 721EX-3605 Dual Sensor Pressure Calibrator, 36 PSIG/500 PSIG
Features
- Can be configured by selecting either a 16 psi (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then add any of 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar)
- Two isolated, stainless steel, pressure sensors with 0.025% accuracy
- Switch test on both pressure inputs
- Pressure displayed in the user’s choice of 19 engineering units: psi, bar, mbar, kPa, kgcm2, cmH2O @ 4°C, cmH2O @ 20°C, mH2O @ 4°C, mH2O @ 20°C, inH2O @ 4°C, inH2O @ 20°C, inH2O @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH2O @ 4°C, ftH2O @ 20°C, ftH2O @ 60°F
- Precision temperature measurement with optional RTD probe
- Measures 4 to 20 mA signals
- Large backlit graphic display shows up to three inputs simultaneously
- Store five instrument setups for recall and use
Fluke 721EX-3603 Dual Sensor Pressure Calibrator, 36 PSIG/300 PSIG
Features
- Can be configured by selecting either a 16 psi (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then add any of 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar)
- Two isolated, stainless steel, pressure sensors with 0.025% accuracy
- Switch test on both pressure inputs
- Pressure displayed in the user’s choice of 19 engineering units: psi, bar, mbar, kPa, kgcm2, cmH2O @ 4°C, cmH2O @ 20°C, mH2O @ 4°C, mH2O @ 20°C, inH2O @ 4°C, inH2O @ 20°C, inH2O @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH2O @ 4°C, ftH2O @ 20°C, ftH2O @ 60°F
- Precision temperature measurement with optional RTD probe
- Measures 4 to 20 mA signals
- Large backlit graphic display shows up to three inputs simultaneously
- Store five instrument setups for recall and use
Fluke 721EX-3601 Dual Sensor Pressure Calibrator, 36 PSIG/100 PSIG
Features
- Can be configured by selecting either a 16 psi (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then add any of 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar)
- Two isolated, stainless steel, pressure sensors with 0.025% accuracy
- Switch test on both pressure inputs
- Pressure displayed in the user’s choice of 19 engineering units: psi, bar, mbar, kPa, kgcm2, cmH2O @ 4°C, cmH2O @ 20°C, mH2O @ 4°C, mH2O @ 20°C, inH2O @ 4°C, inH2O @ 20°C, inH2O @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH2O @ 4°C, ftH2O @ 20°C, ftH2O @ 60°F
- Precision temperature measurement with optional RTD probe
- Measures 4 to 20 mA signals
- Large backlit graphic display shows up to three inputs simultaneously
- Store five instrument setups for recall and use
Fluke 721EX-1650 Dual Sensor Pressure Calibrator, 16 PSIG/5000 PSIG
Features
- Can be configured by selecting either a 16 psi (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then add any of 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar)
- Two isolated, stainless steel, pressure sensors with 0.025% accuracy
- Switch test on both pressure inputs
- Pressure displayed in the user’s choice of 19 engineering units: psi, bar, mbar, kPa, kgcm2, cmH2O @ 4°C, cmH2O @ 20°C, mH2O @ 4°C, mH2O @ 20°C, inH2O @ 4°C, inH2O @ 20°C, inH2O @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH2O @ 4°C, ftH2O @ 20°C, ftH2O @ 60°F
- Precision temperature measurement with optional RTD probe
- Measures 4 to 20 mA signals
- Large backlit graphic display shows up to three inputs simultaneously
- Store five instrument setups for recall and use
Fluke 721EX-1610 Dual Sensor Pressure Calibrator, 16 PSIG/1000 PSIG
Features
- Can be configured by selecting either a 16 psi (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then add any of 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar)
- Two isolated, stainless steel, pressure sensors with 0.025% accuracy
- Switch test on both pressure inputs
- Pressure displayed in the user’s choice of 19 engineering units: psi, bar, mbar, kPa, kgcm2, cmH2O @ 4°C, cmH2O @ 20°C, mH2O @ 4°C, mH2O @ 20°C, inH2O @ 4°C, inH2O @ 20°C, inH2O @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH2O @ 4°C, ftH2O @ 20°C, ftH2O @ 60°F
- Precision temperature measurement with optional RTD probe
- Measures 4 to 20 mA signals
- Large backlit graphic display shows up to three inputs simultaneously
- Store five instrument setups for recall and use