For use with 724, 725 and 726 Temperature Calibrators.
View cart “Fluke 719-30G Electric Pressure Calibrator, 30 PSI” has been added to your cart.
-10%
Previous product
Back to products Fluke 3PHVL-17XX Cable Assembly Voltage Test Lead 3-Phase - 5m $205.00 $185.00
Excluding GST 10%
Next product
Fluke C771 Soft Case Black/Yellow for Fluke-771 $38.00 $34.00
Excluding GST 10%
Fluke 1919047 Calibration Cable
$470.00 $423.00Excluding GST 10%
Available on backorder
SKU: 4443929 Categories: Fluke Calibration Equipment, Temperature Calibration
Related products
Fluke 789 / T3000 FC Process Meter / Temp Kit
Excluding GST 10%
Features
- Compatible with Fluke Connect Mobile App
- 24 V loop power supply
- 1000 V RMS max voltage applied between any jack and earth ground
- Range and resolutions:
- VDC: 400.mV, 4.000 V, 40.00 V, 400.0 V, 1000 V
- VAC (true-rms): 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V
- mA DC: 30.000 mA
- A DC: 1.000 A (0.440 A continuous)
- A AC: 1.000 A (0.440 A continuous)
- HART mode setting with loop power (adds 250 ohm resistor)
- 1200 ohm drive capability on mA source
- Enhanced backlight with two brightness settings
- 0 to 100% mA Span check buttons to toggle between 4 and 20 mA
- Infrared I/O serial port compatible with FlukeView
- -4° to 131°F (-20° to 55°C) operating temperature
Fluke 707 Current Loop Calibrator
Excluding GST 10%
Key features
- High performance loop calibrator for calibration, repair, and maintenance
- Features large display and simple, quick-click interface for easy one-handed operation.
- Provides simultaneous mA and % readout for quick, easy interpretation of readings.
- Delivers mA accuracy of 0.015%
- Provides 1 µA resolution for mA source, simulate, and measure
Fluke 773 Milliamp Process Clamp Meter
Excluding GST 10%
Key features
- Loop calibrator that measures 4 to 20 mA signals without breaking the loop
- Features best in class 0.2% accuracy
- Sources 4 to 20 mA signals for testing control system I/O or I/Ps
- Delivers 0.01 mA resolution and sensitivity
- Measures DC voltage to verify 24V power supplies or voltage I/O signals
Fluke 787B Process Meter
Excluding GST 10%
Features
- 400mV up to 1000V voltage range
- Fluke connect
- 20 mA dc current source/measure/simulate
- Simultaneous mA and % of scale readout
- Frequency measurement up to 20 kHz
- Meets IEC 61010 CAT III and 600 V CAT IV standards
- Min/max/average/hold/relative modes
- Diode test and continuity beeper
- -4 to 131°F (-20 to 55°C) operating temp range
Fluke 705 Loop Calibrator
Excluding GST 10%
Key features
- Powerful loop calibrator that provides a very cost effective, integrated solution for calibration, repair, and maintenance of milliamp loops
- Provides simultaneous mA and % readout for quick, easy interpretation of readings.
- Delivers mA accuracy of 0.02%
- Features push button 25% steps for fast, easy linearity checks
Fluke 772 Milliamp Process Clamp Meter
Excluding GST 10%
Features
- mA Measurement Range / Accuracy
- 0 to 20.99 mA / 0.2% + 5 counts (clamp)
- 21.0 to 100.0 mA / 1% + 5 counts (clamp)
- 0 to 24 mA / 0.2% + 2 counts (test jacks)
- mA Source Range / Accuracy
- 0 to 24.00 mA 0.2% / + 2 counts
- mA Simulate Range / Accuracy
- 0 to 24.00 mA 0.2% / + 2 counts
- Simultaneously measure mA in-circuit with 24V loop power
- auto-off, backlight timeout extend battery life
Fluke Calibration 1524 Dual Channel Reference Thermometer
$3,370.00
Excluding GST 10%
Features
- Sensor types: PRTs, RTDs, thermistors, and thermocouples
- PRT Accuracy: up to ± 0.011 °C
- Thermocouple Accuracy: up to ± 0.24 °C
- Precision thermistor Accuracy: ± 0.002 °C
- Two models:
- 1523: Single channel standard model with memory for 25 readings
- 1524: Two channels; memory for logging 15,000 measurements
- 0.3 second typical sample interval
- Thermocouple types C, E, J, K, L, M, N, T, U, B, R, S
- Statistics: maximum, minimum, average, standard deviation
Fluke Calibration 1523 Single Channel Reference Thermometer
$2,820.00
Excluding GST 10%
Features
- Sensor types: PRTs, RTDs, thermistors, and thermocouples
- PRT Accuracy: up to ± 0.011 °C
- Thermocouple Accuracy: up to ± 0.24 °C
- Precision thermistor Accuracy: ± 0.002 °C
- Two models:
- 1523: Single channel standard model with memory for 25 readings
- 1524: Two channels; memory for logging 15,000 measurements
- 0.3 second typical sample interval
- Thermocouple types C, E, J, K, L, M, N, T, U, B, R, S
- Statistics: maximum, minimum, average, standard deviation