SPRTs designed by Fluke Calibration are known for their outstanding reliability and minimal long-term drift. They have been calibrated by national (and other primary) laboratories and proven repeatedly to outperform competitive models. Now Fluke Calibration’s 5699 Extended Range Metal-Sheath SPRT combines all the advantages of a Fluke Calibration-designed sensor with the protective sheathing materials that allow your SPRT to be used in virtually any furnace or bath with temperatures as high as 670 °C.
“Fluke 715 Volt/mA Loop Calibrator” has been added to your cart. View cart
Fluke 5699 High-Temperature Metal-Sheath SPRT
- Range to aluminum point (660 °C )
- Inconel™ and platinum sheaths guard against contamination
- Less than 8 mK/year drift
- Many calibration options available including by fixed point
- Fifth wire provides shield ground
Categories: Fluke Calibration Equipment, Temperature Calibration
Related products
Fluke 787B Process Meter
$2,120.00
Excluding GST 10%
Features
- 400mV up to 1000V voltage range
- Fluke connect
- 20 mA dc current source/measure/simulate
- Simultaneous mA and % of scale readout
- Frequency measurement up to 20 kHz
- Meets IEC 61010 CAT III and 600 V CAT IV standards
- Min/max/average/hold/relative modes
- Diode test and continuity beeper
- -4 to 131°F (-20 to 55°C) operating temp range
Fluke 700HTPK2 Hydraulic Test Pressure Kit
$3,182.00
Excluding GST 10%
Features
- Generate pressure up to 10,000 psi, 690 bar with the included 700HTP-2 test pump
- Includes 700TTH 10K premium/no tools required transmitter test hose kit and adapters
- Hard case protects pump and gauge and allows gauge to remain connected to the pump
- Can be combined with any Fluke 700G Series Gauge, 1,000 psi range or greater, to make a complete pressure testing kit
Fluke 726 Precision Multifunction Process Calibrator
$7,150.00
Excluding GST 10%
Features
- Up to 20V (source), up to 30V (measure)
- 0 to 24mA source and simulate
- Up to 4000Ω resistance
- Frequency up to 15kHz
- RTD and thermocouple compatible
- Combine with a 750P module for pressure
- Memory storage for up to 8 calibration results
- Perform fast linearity tests with auto step & auto ramp
- 24VDC Loop Supply
- 3-year warranty
Fluke 709 Precision mA Loop Calibrator
$1,877.00
Excluding GST 10%
Key features
- mA precision loop calibrator with best-in-class accuracy at 0.01% reading
- Provides intuitive user interface with quick-set rotary encoder knob for fast setup
- Includes built in selectable 250 Ω resistor for HART communication
- Features 24 V DC loop power with mA Measure Mode (-25% to 125%)
- Requires only simple two wire connection for all measurements
Fluke 712B RTD Temperature Calibrator
$2,846.00
Excluding GST 10%
Features
- Measure and simulate (13) different RTD types and resistance
- Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Configurable 0 % and 100 % source settings
- Linear ramp and 25 % step auto ramp
- Dual inputs and backlit display
- Power down settings
- Max voltage applied between terminal and earth: 30V
- Operating temp: 14 to 122°F (-10 to 50°C)
Fluke 773 Milliamp Process Clamp Meter
$2,400.00
Excluding GST 10%
Key features
- Loop calibrator that measures 4 to 20 mA signals without breaking the loop
- Features best in class 0.2% accuracy
- Sources 4 to 20 mA signals for testing control system I/O or I/Ps
- Delivers 0.01 mA resolution and sensitivity
- Measures DC voltage to verify 24V power supplies or voltage I/O signals
Fluke 771 Milliamp Process Clamp Meter
$1,267.00
Excluding GST 10%
Features
- 0.2% or reading + 5 counts accuracy at -20.99 mA to 20.99 mA
- 1% or reading + 5 counts accuracy at -21.0 mA to -99.9 mA and 21.0 mA to 99.9 mA
- 0.177 in or 4.5mm max diameter of measurable conductor
- -10° to 55°C operating temperature
- IP40 rating
Fluke Calibration 1523 Single Channel Reference Thermometer
$2,820.00
Excluding GST 10%
Features
- Sensor types: PRTs, RTDs, thermistors, and thermocouples
- PRT Accuracy: up to ± 0.011 °C
- Thermocouple Accuracy: up to ± 0.24 °C
- Precision thermistor Accuracy: ± 0.002 °C
- Two models:
- 1523: Single channel standard model with memory for 25 readings
- 1524: Two channels; memory for logging 15,000 measurements
- 0.3 second typical sample interval
- Thermocouple types C, E, J, K, L, M, N, T, U, B, R, S
- Statistics: maximum, minimum, average, standard deviation