The Fluke Calibration 5960A Triple Point of Argon System enables primary standards laboratories to realize the argon triple point using a consistent, reproducible process with the lowest uncertainty of any commercially available system. The Fluke Calibration system produces a 30-hour temperature plateau and provides multiple entrant wells to increase SPRT calibration efficiency and throughput.
“Fluke Calibration 1523 Single Channel Reference Thermometer” has been added to your cart. View cart
Fluke 5960A Triple Point of Argon System
- Low uncertainty of 0.25 mK
- Temperature plateau duration longer than 30 hours
- Four entrant wells with radial uniformity less than 0.05 mK
- 480 mm total immersion depth
- Argon purity of 99.9999 %
- Multi-language display support
Categories: Fluke Calibration Equipment, Temperature Calibration
Related products
Fluke 787B Process Meter
$2,120.00
Excluding GST 10%
Features
- 400mV up to 1000V voltage range
- Fluke connect
- 20 mA dc current source/measure/simulate
- Simultaneous mA and % of scale readout
- Frequency measurement up to 20 kHz
- Meets IEC 61010 CAT III and 600 V CAT IV standards
- Min/max/average/hold/relative modes
- Diode test and continuity beeper
- -4 to 131°F (-20 to 55°C) operating temp range
Fluke 707 Current Loop Calibrator
$1,929.00
Excluding GST 10%
Key features
- High performance loop calibrator for calibration, repair, and maintenance
- Features large display and simple, quick-click interface for easy one-handed operation.
- Provides simultaneous mA and % readout for quick, easy interpretation of readings.
- Delivers mA accuracy of 0.015%
- Provides 1 µA resolution for mA source, simulate, and measure
Fluke 789 / T3000 FC Process Meter / Temp Kit
$2,552.00
Excluding GST 10%
Features
- Compatible with Fluke Connect Mobile App
- 24 V loop power supply
- 1000 V RMS max voltage applied between any jack and earth ground
- Range and resolutions:
- VDC: 400.mV, 4.000 V, 40.00 V, 400.0 V, 1000 V
- VAC (true-rms): 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V
- mA DC: 30.000 mA
- A DC: 1.000 A (0.440 A continuous)
- A AC: 1.000 A (0.440 A continuous)
- HART mode setting with loop power (adds 250 ohm resistor)
- 1200 ohm drive capability on mA source
- Enhanced backlight with two brightness settings
- 0 to 100% mA Span check buttons to toggle between 4 and 20 mA
- Infrared I/O serial port compatible with FlukeView
- -4° to 131°F (-20° to 55°C) operating temperature
Fluke 709H Precision mA Loop Calibrator with HART Communications
$2,711.00
Excluding GST 10%
Key features
- mA precision loop calibrator that communicates with and tests HART smart instruments
- Features best-in-class accuracy at 0.01% reading
- Provides intuitive user interface with Quick-Set knob for fast setup
- Includes built in selectable 250 Ω resistor for HART communication
- Features 24 V DC loop power with mA measure mode (-25% to 125%)
Fluke Calibration 1523 Single Channel Reference Thermometer
$2,820.00
Excluding GST 10%
Features
- Sensor types: PRTs, RTDs, thermistors, and thermocouples
- PRT Accuracy: up to ± 0.011 °C
- Thermocouple Accuracy: up to ± 0.24 °C
- Precision thermistor Accuracy: ± 0.002 °C
- Two models:
- 1523: Single channel standard model with memory for 25 readings
- 1524: Two channels; memory for logging 15,000 measurements
- 0.3 second typical sample interval
- Thermocouple types C, E, J, K, L, M, N, T, U, B, R, S
- Statistics: maximum, minimum, average, standard deviation
Fluke 772 Milliamp Process Clamp Meter
Excluding GST 10%
Features
- mA Measurement Range / Accuracy
- 0 to 20.99 mA / 0.2% + 5 counts (clamp)
- 21.0 to 100.0 mA / 1% + 5 counts (clamp)
- 0 to 24 mA / 0.2% + 2 counts (test jacks)
- mA Source Range / Accuracy
- 0 to 24.00 mA 0.2% / + 2 counts
- mA Simulate Range / Accuracy
- 0 to 24.00 mA 0.2% / + 2 counts
- Simultaneously measure mA in-circuit with 24V loop power
- auto-off, backlight timeout extend battery life
Fluke 714B Temperature Calibrator
$2,984.00
Excluding GST 10%
Features
- Measure and simulate 17 different thermocouple types
- Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Configurable 0 % and 100 % source settings
- Linear ramp and 25 % step auto ramp
- Dual inputs and backlit display
- Power down settings
- Max voltage applied between terminal and earth: 30V
- Operating temp: 14 to 122°F (-10 to 50°C)
- Hanging tool designed in and included with every unit
Fluke 700PTPK2 Pneumatic Test Pressure Kit
$3,041.00
Excluding GST 10%
Features
- Combine with any Fluke 700G Series Gauge, 1,000 psi (69 bar) or less, to make a complete pressure testing kit
- Generate pressure up to 600 psi, 40 bar with the 700PTP-1 test pump
- Connect the 700G Series Gauge directly to the included PTP-1 hand pump with premium no tools required adapter
- Includes 700TTH 5K premium/no tools required transmitter test hose kit and adapters for connecting to the pressure device to be tested
- Hard case protects pump and gauge and allows gauge to remain connected to the pump