- Parameter/Range:-1 to 1 psi (-70 to 70 mBar)
- Burst Rating6:4X
- Hi Side Media2:316 SS
- Lo Side Media2:Dry Air
- Reference Uncertainty4:± 0.05%
- Total Uncertainty 1-year (15-35°C):± 0.1%
- Total Uncertainty 1-year1:± 0.15%
- Total Uncertainty 6-month (15-35°C):± 0.075%
- Total Uncertainty 6-month1:± 0.125%
Available on backorder
SKU: 4352539
Categories: Fluke Calibration Equipment, Pressure Calibration
Related products
Fluke 789 / T3000 FC Process Meter / Temp Kit
$2,552.00
Excluding GST 10%
Features
- Compatible with Fluke Connect Mobile App
- 24 V loop power supply
- 1000 V RMS max voltage applied between any jack and earth ground
- Range and resolutions:
- VDC: 400.mV, 4.000 V, 40.00 V, 400.0 V, 1000 V
- VAC (true-rms): 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V
- mA DC: 30.000 mA
- A DC: 1.000 A (0.440 A continuous)
- A AC: 1.000 A (0.440 A continuous)
- HART mode setting with loop power (adds 250 ohm resistor)
- 1200 ohm drive capability on mA source
- Enhanced backlight with two brightness settings
- 0 to 100% mA Span check buttons to toggle between 4 and 20 mA
- Infrared I/O serial port compatible with FlukeView
- -4° to 131°F (-20° to 55°C) operating temperature
Fluke 724 Temperature Calibrator
$5,248.00
Excluding GST 10%
Features
- Measure Accuracy
- RTD: .2 to .33°C
- Thermocouples: .7 to 1.8°C
- Voltage DC: 0.025% to 0.02%
- Current DC: 0.02%
- Resistance: 0.1 to 1.5%
- Source Accuracy
- Voltage DC: 0.025 to 0.02%
- Resistance: 0.15Ω to 1Ω
Fluke 709H Precision mA Loop Calibrator with HART Communications
$2,711.00
Excluding GST 10%
Key features
- mA precision loop calibrator that communicates with and tests HART smart instruments
- Features best-in-class accuracy at 0.01% reading
- Provides intuitive user interface with Quick-Set knob for fast setup
- Includes built in selectable 250 Ω resistor for HART communication
- Features 24 V DC loop power with mA measure mode (-25% to 125%)
Fluke 725 Multifunction Process Calibrator
$5,319.00
Excluding GST 10%
Features
- Up to 30V and 24mA DC
- 0 to 3200Ω resistance
- Up to 10kHz frequency
- 1V peak-to-peak-minimum senitivity
- Combine with a 750P module for pressure
- Store frequently used test setups for later use
Fluke 714B Temperature Calibrator
$2,984.00
Excluding GST 10%
Features
- Measure and simulate 17 different thermocouple types
- Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Configurable 0 % and 100 % source settings
- Linear ramp and 25 % step auto ramp
- Dual inputs and backlit display
- Power down settings
- Max voltage applied between terminal and earth: 30V
- Operating temp: 14 to 122°F (-10 to 50°C)
- Hanging tool designed in and included with every unit
Fluke 705 Loop Calibrator
$1,725.00
Excluding GST 10%
Key features
- Powerful loop calibrator that provides a very cost effective, integrated solution for calibration, repair, and maintenance of milliamp loops
- Provides simultaneous mA and % readout for quick, easy interpretation of readings.
- Delivers mA accuracy of 0.02%
- Features push button 25% steps for fast, easy linearity checks
Fluke 771 Milliamp Process Clamp Meter
$1,267.00
Excluding GST 10%
Features
- 0.2% or reading + 5 counts accuracy at -20.99 mA to 20.99 mA
- 1% or reading + 5 counts accuracy at -21.0 mA to -99.9 mA and 21.0 mA to 99.9 mA
- 0.177 in or 4.5mm max diameter of measurable conductor
- -10° to 55°C operating temperature
- IP40 rating
Fluke Calibration 1524 Dual Channel Reference Thermometer
$3,370.00
Excluding GST 10%
Features
- Sensor types: PRTs, RTDs, thermistors, and thermocouples
- PRT Accuracy: up to ± 0.011 °C
- Thermocouple Accuracy: up to ± 0.24 °C
- Precision thermistor Accuracy: ± 0.002 °C
- Two models:
- 1523: Single channel standard model with memory for 25 readings
- 1524: Two channels; memory for logging 15,000 measurements
- 0.3 second typical sample interval
- Thermocouple types C, E, J, K, L, M, N, T, U, B, R, S