Specifications
- Parameter/Range:-12 to 100 psi (-1 to 7 bar)
- Burst Rating6:4X
- Hi Side Media2:316 SS
- Lo Side Media2:-
- Reference Uncertainty4:±0.01% of FS
- Total Uncertainty 1-year (15-35°C):± 0.02% of FS
- Total Uncertainty 1-year1:± 0.04% of FS
- Total Uncertainty 6-month (15-35°C):± 0.015% of FS
- Total Uncertainty 6-month1:± 0.035% of FS
Available on backorder
SKU: 4352714
Categories: Fluke Calibration Equipment, Pressure Calibration
Related products
Fluke 725 Multifunction Process Calibrator
$5,319.00
Excluding GST 10%
Features
- Up to 30V and 24mA DC
- 0 to 3200Ω resistance
- Up to 10kHz frequency
- 1V peak-to-peak-minimum senitivity
- Combine with a 750P module for pressure
- Store frequently used test setups for later use
Fluke Calibration 1524 Dual Channel Reference Thermometer
$3,370.00
Excluding GST 10%
Features
- Sensor types: PRTs, RTDs, thermistors, and thermocouples
- PRT Accuracy: up to ± 0.011 °C
- Thermocouple Accuracy: up to ± 0.24 °C
- Precision thermistor Accuracy: ± 0.002 °C
- Two models:
- 1523: Single channel standard model with memory for 25 readings
- 1524: Two channels; memory for logging 15,000 measurements
- 0.3 second typical sample interval
- Thermocouple types C, E, J, K, L, M, N, T, U, B, R, S
- Statistics: maximum, minimum, average, standard deviation
Fluke 709 Precision mA Loop Calibrator
$1,877.00
Excluding GST 10%
Key features
- mA precision loop calibrator with best-in-class accuracy at 0.01% reading
- Provides intuitive user interface with quick-set rotary encoder knob for fast setup
- Includes built in selectable 250 Ω resistor for HART communication
- Features 24 V DC loop power with mA Measure Mode (-25% to 125%)
- Requires only simple two wire connection for all measurements
Fluke 724 Temperature Calibrator
$5,248.00
Excluding GST 10%
Features
- Measure Accuracy
- RTD: .2 to .33°C
- Thermocouples: .7 to 1.8°C
- Voltage DC: 0.025% to 0.02%
- Current DC: 0.02%
- Resistance: 0.1 to 1.5%
- Source Accuracy
- Voltage DC: 0.025 to 0.02%
- Resistance: 0.15Ω to 1Ω
Fluke 718Ex Pressure Calibrator
$6,663.00
Excluding GST 10%
Features
- ATEX II 1G Ex ia IIC T4 Compliant
- Built-in pressure / vacuum hand pump, with fine adjust vernier and bleed valve
- 30, 100, and 300 psi ranges (2, 7, and 20 bar)
- Pressure measurement to 0.05% of full span, using an internal pressure sensor
- Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules
- Wide range of selectable measurement units for pressure
- Current measurement with 0.02% accuracy and 0.001 mA resolution
- Pressure switch test function
- Min-Max Hold functions
- Compact size and weight
- Simple, push-button user interface
- Rugged and reliable, ideal for field use
Fluke 787B Process Meter
$2,120.00
Excluding GST 10%
Features
- 400mV up to 1000V voltage range
- Fluke connect
- 20 mA dc current source/measure/simulate
- Simultaneous mA and % of scale readout
- Frequency measurement up to 20 kHz
- Meets IEC 61010 CAT III and 600 V CAT IV standards
- Min/max/average/hold/relative modes
- Diode test and continuity beeper
- -4 to 131°F (-20 to 55°C) operating temp range
Fluke 772 Milliamp Process Clamp Meter
Excluding GST 10%
Features
- mA Measurement Range / Accuracy
- 0 to 20.99 mA / 0.2% + 5 counts (clamp)
- 21.0 to 100.0 mA / 1% + 5 counts (clamp)
- 0 to 24 mA / 0.2% + 2 counts (test jacks)
- mA Source Range / Accuracy
- 0 to 24.00 mA 0.2% / + 2 counts
- mA Simulate Range / Accuracy
- 0 to 24.00 mA 0.2% / + 2 counts
- Simultaneously measure mA in-circuit with 24V loop power
- auto-off, backlight timeout extend battery life
Fluke Calibration 1523 Single Channel Reference Thermometer
$2,820.00
Excluding GST 10%
Features
- Sensor types: PRTs, RTDs, thermistors, and thermocouples
- PRT Accuracy: up to ± 0.011 °C
- Thermocouple Accuracy: up to ± 0.24 °C
- Precision thermistor Accuracy: ± 0.002 °C
- Two models:
- 1523: Single channel standard model with memory for 25 readings
- 1524: Two channels; memory for logging 15,000 measurements
- 0.3 second typical sample interval
- Thermocouple types C, E, J, K, L, M, N, T, U, B, R, S
- Statistics: maximum, minimum, average, standard deviation