The Fluke 787B Process Meter combine the power of a safety rated digital multimeter and mA loop calibrator into a single, compact test tool. Whether you only need to source and simulate mA, or need a 24V loop power supply, Fluke has a Process Meter test tool designed specifically to meet your needs. Based on the trusted measurement capabilities of the Fluke 87 DMM, the 787B and 789 add the ability to measure, source and simulate mA with the accuracy and resolution you would expect from a Fluke mA loop calibrator, giving you the ideal tool for troubleshooting and calibrating current loop applications.
“Fluke 700HTPK2 Hydraulic Test Pressure Kit” has been added to your cart. View cart
Previous product
Back to products
Kyoritsu 3132A Insulation & Continuity Tester
$399.00
Excluding GST 10%
Next product
Fluke 709H Precision mA Loop Calibrator with HART Communications
$2,711.00
Excluding GST 10%
Fluke 787B Process Meter
$2,120.00Excluding GST 10%
Features
- 400mV up to 1000V voltage range
- Fluke connect
- 20 mA dc current source/measure/simulate
- Simultaneous mA and % of scale readout
- Frequency measurement up to 20 kHz
- Meets IEC 61010 CAT III and 600 V CAT IV standards
- Min/max/average/hold/relative modes
- Diode test and continuity beeper
- -4 to 131°F (-20 to 55°C) operating temp range
Available on backorder
SKU: 4777186
Categories: Fluke Calibration Equipment, Process Calibration
Related products
Fluke 9142 – Field Metrology Wells
$10,362.00
Excluding GST 10%
Key Features:
- Lightweight, portable, and fast
- Cool to –25 °C in 15 minutes and heat to 660°C in 15 minutes
- Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
- True reference thermometry with accuracy to ±0.01 °C
- On-board automation and documentation
- Metrology performance in accuracy, stability, uniformity, and loading
Fluke 772 Milliamp Process Clamp Meter
Excluding GST 10%
Features
- mA Measurement Range / Accuracy
- 0 to 20.99 mA / 0.2% + 5 counts (clamp)
- 21.0 to 100.0 mA / 1% + 5 counts (clamp)
- 0 to 24 mA / 0.2% + 2 counts (test jacks)
- mA Source Range / Accuracy
- 0 to 24.00 mA 0.2% / + 2 counts
- mA Simulate Range / Accuracy
- 0 to 24.00 mA 0.2% / + 2 counts
- Simultaneously measure mA in-circuit with 24V loop power
- auto-off, backlight timeout extend battery life
Fluke 712B RTD Temperature Calibrator
$2,846.00
Excluding GST 10%
Features
- Measure and simulate (13) different RTD types and resistance
- Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Configurable 0 % and 100 % source settings
- Linear ramp and 25 % step auto ramp
- Dual inputs and backlit display
- Power down settings
- Max voltage applied between terminal and earth: 30V
- Operating temp: 14 to 122°F (-10 to 50°C)
Fluke 719Pro Electric Pressure Calibrator
$8,739.00
Excluding GST 10%
Features
- Electric pump for one handed pressure calibration
- Best in class pressure measurement uncertainty of 0.025%
- Measure and source mA with best in class 0.015% accuracy
- Precision pressure adjust vernier for accurate pressure calibration
- Variable release rate bleed valve for easy pressure adjustment
- Programmable pressure calibrator pump limit: eliminates over-pressurization and allows the user to program target pressures for pumping
- Programmable 3-tiered display for maximum flexibility when displaying pressure, temperature, and electrical parameters of your choice
- Display backlight
- Damping, Min/Max, and % error function
- Source mA with simultaneous pressure measurement to test valves and I/Ps
- Simulate mA signals to troubleshoot 4-20 mA loops
- Test pressure switches with built in switch test function
- Power transmitters during test using 24 V loop supply with simultaneous mA measurement
- Precision temperature measurement with the addition of an accessory RTD probe (available as an option)
- Proven cleanout ports reduce pump failures
- Moisture trap included with the unit helps mitigates risk of moisture damage
Applications
- Pressure Instrument Calibration
- Pressure Instrument Maintenance
- Petro-Chemical
- Oil and Gas
- Pharmaceutical
- Water and wastewater
- Food and Beverage
- Power Generation
Fluke 719-30G Electric Pressure Calibrator, 30 PSI
$8,351.00
Excluding GST 10%
Features
- Fluke 719 30G
- Range: -12 to 36 PSI
- Resolution: 0.001 PSI,
- Accuracy: up to 0.025%
- Fluke 719 100G
- Range: -12 to 120 PSI
- Resolution: 0.01 PSI
- Accuracy: up to 0.025%
- mA:
- Range: 0 to 24 mA
- Accuracy: 0.015 % Rdg + 2 counts
- Max load: 1000Ω; 750 Ω ohm in HART mode
- Pump to:
- 30 PSI in less than 15 seconds (1m of 1/8″ test hose)
- 100 PSI in less than 45 seconds (1m of 1/8″ test hose)
- 5000 pump cycles between rebuilds
- Pump life: 20,000 calibration cycle
- Safety: CSA C22.2 No. 1010.1:1992
- EMC: EN50082-1:1992 and EN55022:1994 Class B
Fluke 700HTPK Hydraulic Test Kit
$2,399.00
Excluding GST 10%
The Fluke-700HTPK Hydraulic Test Kit
- Combine with any Fluke-700G Series Gauge, 1,000 psi range or greater, to make a complete pressure testing kit
- Generate pressure up to 10,000 psi, 690 bar with the included 700HTP-2 test pump
- Connect the 700G Series gauge directly to the HTP-2 hand pump
- Includes 700HTH-1 hose kit and adapters for connecting to the pressure device to be tested
- Hard case protects pump and gauge and allows gauge to remain connected to the pump
Fluke 726 Precision Multifunction Process Calibrator
$7,150.00
Excluding GST 10%
Features
- Up to 20V (source), up to 30V (measure)
- 0 to 24mA source and simulate
- Up to 4000Ω resistance
- Frequency up to 15kHz
- RTD and thermocouple compatible
- Combine with a 750P module for pressure
- Memory storage for up to 8 calibration results
- Perform fast linearity tests with auto step & auto ramp
- 24VDC Loop Supply
- 3-year warranty
Fluke 789 / T3000 FC Process Meter / Temp Kit
$2,552.00
Excluding GST 10%
Features
- Compatible with Fluke Connect Mobile App
- 24 V loop power supply
- 1000 V RMS max voltage applied between any jack and earth ground
- Range and resolutions:
- VDC: 400.mV, 4.000 V, 40.00 V, 400.0 V, 1000 V
- VAC (true-rms): 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V
- mA DC: 30.000 mA
- A DC: 1.000 A (0.440 A continuous)
- A AC: 1.000 A (0.440 A continuous)
- HART mode setting with loop power (adds 250 ohm resistor)
- 1200 ohm drive capability on mA source
- Enhanced backlight with two brightness settings
- 0 to 100% mA Span check buttons to toggle between 4 and 20 mA
- Infrared I/O serial port compatible with FlukeView
- -4° to 131°F (-20° to 55°C) operating temperature