The Fluke Calibration 9118A Thermocouple Calibration Furnace is a horizontal, open-ended tube furnace with a temperature range of 300 °C to 1200 °C. It is used for comparison calibration of noble and base-metal thermocouples by secondary high-temperature labs and instrument shops in industries such as aerospace, automotive, energy, metals, and plastics. The 9118A is the most accurate, reliable, and flexible furnace in its class, meeting the demanding requirements of high-temperature thermocouple calibration.
View cart “Fluke 718Ex Pressure Calibrator” has been added to your cart.
Fluke 9118A Thermocouple Calibration Furnace
- Tube furnace configuration (without isothermal block): Base-metal thermocouples are often sheathed in formable materials such as braided fiberglass or PTFE. During calibration, they are bundled around a reference thermometer, held together with fiberglass cord or tape, and inserted into a tube furnace.
- Isothermal block configuration: Metal- or ceramic-sheathed thermocouples are generally constructed with noble-metal thermoelements and therefore have higher calibration accuracy requirements. The isothermal block, which accommodates up to four 6.35 millimeter probes, improves heat transfer and temperature stability. This better equalizes the temperature between the reference probe and the UUT, which lowers measurement uncertainty compared to calibration without a block.
Categories: Fluke Calibration Equipment, Temperature Calibration
Related products
Fluke 705 Loop Calibrator
Excluding GST 10%
Key features
- Powerful loop calibrator that provides a very cost effective, integrated solution for calibration, repair, and maintenance of milliamp loops
- Provides simultaneous mA and % readout for quick, easy interpretation of readings.
- Delivers mA accuracy of 0.02%
- Features push button 25% steps for fast, easy linearity checks
-10%
Close
Fluke 700PTPK2 Pneumatic Test Pressure Kit
Excluding GST 10%
Features
- Combine with any Fluke 700G Series Gauge, 1,000 psi (69 bar) or less, to make a complete pressure testing kit
- Generate pressure up to 600 psi, 40 bar with the 700PTP-1 test pump
- Connect the 700G Series Gauge directly to the included PTP-1 hand pump with premium no tools required adapter
- Includes 700TTH 5K premium/no tools required transmitter test hose kit and adapters for connecting to the pressure device to be tested
- Hard case protects pump and gauge and allows gauge to remain connected to the pump
Fluke 787B Process Meter
Excluding GST 10%
Features
- 400mV up to 1000V voltage range
- Fluke connect
- 20 mA dc current source/measure/simulate
- Simultaneous mA and % of scale readout
- Frequency measurement up to 20 kHz
- Meets IEC 61010 CAT III and 600 V CAT IV standards
- Min/max/average/hold/relative modes
- Diode test and continuity beeper
- -4 to 131°F (-20 to 55°C) operating temp range
Fluke 719Pro Electric Pressure Calibrator
Excluding GST 10%
Features
- Electric pump for one handed pressure calibration
- Best in class pressure measurement uncertainty of 0.025%
- Measure and source mA with best in class 0.015% accuracy
- Precision pressure adjust vernier for accurate pressure calibration
- Variable release rate bleed valve for easy pressure adjustment
- Programmable pressure calibrator pump limit: eliminates over-pressurization and allows the user to program target pressures for pumping
- Programmable 3-tiered display for maximum flexibility when displaying pressure, temperature, and electrical parameters of your choice
- Display backlight
- Damping, Min/Max, and % error function
- Source mA with simultaneous pressure measurement to test valves and I/Ps
- Simulate mA signals to troubleshoot 4-20 mA loops
- Test pressure switches with built in switch test function
- Power transmitters during test using 24 V loop supply with simultaneous mA measurement
- Precision temperature measurement with the addition of an accessory RTD probe (available as an option)
- Proven cleanout ports reduce pump failures
- Moisture trap included with the unit helps mitigates risk of moisture damage
Applications
- Pressure Instrument Calibration
- Pressure Instrument Maintenance
- Petro-Chemical
- Oil and Gas
- Pharmaceutical
- Water and wastewater
- Food and Beverage
- Power Generation
Fluke 719-30G Electric Pressure Calibrator, 30 PSI
Excluding GST 10%
Features
- Fluke 719 30G
- Range: -12 to 36 PSI
- Resolution: 0.001 PSI,
- Accuracy: up to 0.025%
- Fluke 719 100G
- Range: -12 to 120 PSI
- Resolution: 0.01 PSI
- Accuracy: up to 0.025%
- mA:
- Range: 0 to 24 mA
- Accuracy: 0.015 % Rdg + 2 counts
- Max load: 1000Ω; 750 Ω ohm in HART mode
- Pump to:
- 30 PSI in less than 15 seconds (1m of 1/8″ test hose)
- 100 PSI in less than 45 seconds (1m of 1/8″ test hose)
- 5000 pump cycles between rebuilds
- Pump life: 20,000 calibration cycle
- Safety: CSA C22.2 No. 1010.1:1992
- EMC: EN50082-1:1992 and EN55022:1994 Class B
Fluke Calibration 1523 Single Channel Reference Thermometer
$2,820.00
Excluding GST 10%
Features
- Sensor types: PRTs, RTDs, thermistors, and thermocouples
- PRT Accuracy: up to ± 0.011 °C
- Thermocouple Accuracy: up to ± 0.24 °C
- Precision thermistor Accuracy: ± 0.002 °C
- Two models:
- 1523: Single channel standard model with memory for 25 readings
- 1524: Two channels; memory for logging 15,000 measurements
- 0.3 second typical sample interval
- Thermocouple types C, E, J, K, L, M, N, T, U, B, R, S
- Statistics: maximum, minimum, average, standard deviation
Fluke 714B Temperature Calibrator
Excluding GST 10%
Features
- Measure and simulate 17 different thermocouple types
- Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Configurable 0 % and 100 % source settings
- Linear ramp and 25 % step auto ramp
- Dual inputs and backlit display
- Power down settings
- Max voltage applied between terminal and earth: 30V
- Operating temp: 14 to 122°F (-10 to 50°C)
- Hanging tool designed in and included with every unit
Fluke Calibration 1524 Dual Channel Reference Thermometer
$3,370.00
Excluding GST 10%
Features
- Sensor types: PRTs, RTDs, thermistors, and thermocouples
- PRT Accuracy: up to ± 0.011 °C
- Thermocouple Accuracy: up to ± 0.24 °C
- Precision thermistor Accuracy: ± 0.002 °C
- Two models:
- 1523: Single channel standard model with memory for 25 readings
- 1524: Two channels; memory for logging 15,000 measurements
- 0.3 second typical sample interval
- Thermocouple types C, E, J, K, L, M, N, T, U, B, R, S
- Statistics: maximum, minimum, average, standard deviation