Fluke Calibration’s constant volume valve is a pneumatically actuated needle valve with a return line connecting the inlet to a coaxial compensator. Needle displacement is matched by an equal and opposite volume displacement on the compensator.
“Fluke 719-30G Electric Pressure Calibrator, 30 PSI” has been added to your cart. View cart
Fluke Constant Volume Valve
The constant volume valve is used in piston gauge crossfloats and other applications in which two high pressures need to be disconnected and reconnected with minimal purturbations on either side.
Categories: Fluke Calibration Equipment, Pressure Calibration
Related products
Fluke 709H Precision mA Loop Calibrator with HART Communications
$2,711.00
Excluding GST 10%
Key features
- mA precision loop calibrator that communicates with and tests HART smart instruments
- Features best-in-class accuracy at 0.01% reading
- Provides intuitive user interface with Quick-Set knob for fast setup
- Includes built in selectable 250 Ω resistor for HART communication
- Features 24 V DC loop power with mA measure mode (-25% to 125%)
Fluke 709 Precision mA Loop Calibrator
$1,877.00
Excluding GST 10%
Key features
- mA precision loop calibrator with best-in-class accuracy at 0.01% reading
- Provides intuitive user interface with quick-set rotary encoder knob for fast setup
- Includes built in selectable 250 Ω resistor for HART communication
- Features 24 V DC loop power with mA Measure Mode (-25% to 125%)
- Requires only simple two wire connection for all measurements
Fluke Calibration 1524 Dual Channel Reference Thermometer
$3,370.00
Excluding GST 10%
Features
- Sensor types: PRTs, RTDs, thermistors, and thermocouples
- PRT Accuracy: up to ± 0.011 °C
- Thermocouple Accuracy: up to ± 0.24 °C
- Precision thermistor Accuracy: ± 0.002 °C
- Two models:
- 1523: Single channel standard model with memory for 25 readings
- 1524: Two channels; memory for logging 15,000 measurements
- 0.3 second typical sample interval
- Thermocouple types C, E, J, K, L, M, N, T, U, B, R, S
- Statistics: maximum, minimum, average, standard deviation
Fluke 714B Temperature Calibrator
$2,984.00
Excluding GST 10%
Features
- Measure and simulate 17 different thermocouple types
- Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Configurable 0 % and 100 % source settings
- Linear ramp and 25 % step auto ramp
- Dual inputs and backlit display
- Power down settings
- Max voltage applied between terminal and earth: 30V
- Operating temp: 14 to 122°F (-10 to 50°C)
- Hanging tool designed in and included with every unit
Fluke 724 Temperature Calibrator
$5,248.00
Excluding GST 10%
Features
- Measure Accuracy
- RTD: .2 to .33°C
- Thermocouples: .7 to 1.8°C
- Voltage DC: 0.025% to 0.02%
- Current DC: 0.02%
- Resistance: 0.1 to 1.5%
- Source Accuracy
- Voltage DC: 0.025 to 0.02%
- Resistance: 0.15Ω to 1Ω
Fluke 787B Process Meter
$2,120.00
Excluding GST 10%
Features
- 400mV up to 1000V voltage range
- Fluke connect
- 20 mA dc current source/measure/simulate
- Simultaneous mA and % of scale readout
- Frequency measurement up to 20 kHz
- Meets IEC 61010 CAT III and 600 V CAT IV standards
- Min/max/average/hold/relative modes
- Diode test and continuity beeper
- -4 to 131°F (-20 to 55°C) operating temp range
Fluke 773 Milliamp Process Clamp Meter
$2,400.00
Excluding GST 10%
Key features
- Loop calibrator that measures 4 to 20 mA signals without breaking the loop
- Features best in class 0.2% accuracy
- Sources 4 to 20 mA signals for testing control system I/O or I/Ps
- Delivers 0.01 mA resolution and sensitivity
- Measures DC voltage to verify 24V power supplies or voltage I/O signals
Fluke 715 Volt/mA Loop Calibrator
$2,846.00
Excluding GST 10%
Key features
- Compact, lightweight mA calibrator for measuring loop current (0-20 mA, 4-20 mA) signals
- Delivers very high accuracy—0.01%—and 1 mA resolution
- Measures voltage output process signals from PLCs and transmitters
- Sources or simulates 24 mA loop current
- Sources voltage to 100 mV or 10V
- Provides typical 18 hour battery life