Features
- Up to 20V (source), up to 30V (measure)
- 0 to 24mA source and simulate
- Up to 4000Ω resistance
- Frequency up to 15kHz
- RTD and thermocouple compatible
- Combine with a 750P module for pressure
- Memory storage for up to 8 calibration results
- Perform fast linearity tests with auto step & auto ramp
- 24VDC Loop Supply
- 3-year warranty
Fluke 705 Loop Calibrator
$1,725.00
Excluding GST 10%
Key features
- Powerful loop calibrator that provides a very cost effective, integrated solution for calibration, repair, and maintenance of milliamp loops
- Provides simultaneous mA and % readout for quick, easy interpretation of readings.
- Delivers mA accuracy of 0.02%
- Features push button 25% steps for fast, easy linearity checks
Fluke 787B Process Meter
$2,120.00
Excluding GST 10%
Features
- 400mV up to 1000V voltage range
- Fluke connect
- 20 mA dc current source/measure/simulate
- Simultaneous mA and % of scale readout
- Frequency measurement up to 20 kHz
- Meets IEC 61010 CAT III and 600 V CAT IV standards
- Min/max/average/hold/relative modes
- Diode test and continuity beeper
- -4 to 131°F (-20 to 55°C) operating temp range
Fluke 719-30G Electric Pressure Calibrator, 30 PSI
$8,351.00
Excluding GST 10%
Features
- Fluke 719 30G
- Range: -12 to 36 PSI
- Resolution: 0.001 PSI,
- Accuracy: up to 0.025%
- Fluke 719 100G
- Range: -12 to 120 PSI
- Resolution: 0.01 PSI
- Accuracy: up to 0.025%
- mA:
- Range: 0 to 24 mA
- Accuracy: 0.015 % Rdg + 2 counts
- Max load: 1000Ω; 750 Ω ohm in HART mode
- Pump to:
- 30 PSI in less than 15 seconds (1m of 1/8″ test hose)
- 100 PSI in less than 45 seconds (1m of 1/8″ test hose)
- 5000 pump cycles between rebuilds
- Pump life: 20,000 calibration cycle
- Safety: CSA C22.2 No. 1010.1:1992
- EMC: EN50082-1:1992 and EN55022:1994 Class B
Fluke 709H Precision mA Loop Calibrator with HART Communications
$2,711.00
Excluding GST 10%
Key features
- mA precision loop calibrator that communicates with and tests HART smart instruments
- Features best-in-class accuracy at 0.01% reading
- Provides intuitive user interface with Quick-Set knob for fast setup
- Includes built in selectable 250 Ω resistor for HART communication
- Features 24 V DC loop power with mA measure mode (-25% to 125%)
Fluke Calibration 1524 Dual Channel Reference Thermometer
$3,370.00
Excluding GST 10%
Features
- Sensor types: PRTs, RTDs, thermistors, and thermocouples
- PRT Accuracy: up to ± 0.011 °C
- Thermocouple Accuracy: up to ± 0.24 °C
- Precision thermistor Accuracy: ± 0.002 °C
- Two models:
- 1523: Single channel standard model with memory for 25 readings
- 1524: Two channels; memory for logging 15,000 measurements
- 0.3 second typical sample interval
- Thermocouple types C, E, J, K, L, M, N, T, U, B, R, S
- Statistics: maximum, minimum, average, standard deviation
Fluke 724 Temperature Calibrator
$5,248.00
Excluding GST 10%
Features
- Measure Accuracy
- RTD: .2 to .33°C
- Thermocouples: .7 to 1.8°C
- Voltage DC: 0.025% to 0.02%
- Current DC: 0.02%
- Resistance: 0.1 to 1.5%
- Source Accuracy
- Voltage DC: 0.025 to 0.02%
- Resistance: 0.15Ω to 1Ω
Fluke 712B RTD Temperature Calibrator
$2,846.00
Excluding GST 10%
Features
- Measure and simulate (13) different RTD types and resistance
- Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Configurable 0 % and 100 % source settings
- Linear ramp and 25 % step auto ramp
- Dual inputs and backlit display
- Power down settings
- Max voltage applied between terminal and earth: 30V