Quickly and easily check pressure-measuring instruments against master test gauges, indicators or transducers using this pneumatic pressure calibrator, which comes equipped with 4 gauges, is accredited and has a 0 to 300psi range.
Fluke P5510/15-2700G-4/C Offers
This pressure calibrator is portable with a sturdy carrying case.
Features
Best-in-class accuracy of 0.02% full scale for each 2700G Reference Gauge
Expand lower-range capability with additional 2700G Reference Gauges (each sold separately)
Adapters to provide hand-tight connection to common NPT, BSP and metric fitting types
Included reference gauges are battery operated and capable of using line power
Built-in pump for generating both vacuum and positive pressure
Pressure range 0 to 300psi, 2mPa (300psi)
Vacuum range 0 to 27inHg (915mbar)
Up to three 2700G Reference Pressure Gauges
Fine needle vent valve for small adjustment and venting of pressure
Battery Voltage – During the internal resistance test, Fluke Battery Analyzers also measure the voltage of the battery under test
Discharge Volts – The Discharge mode collects the voltage of each battery multiple times at a user defined interval during a discharge or load test. Users can calculate the time a battery takes to drop to the cut-off voltage and use this time to determine the capacity loss of the battery
Ripple Voltage Test – Measures unwanted residual ac component of the rectified voltage in dc charging and inverter circuits. Allows users to test ac components in dc charging circuits and find one of the root causes of battery deterioration
Meter and Sequence Modes – The Meter mode is used for a quick test or troubleshooting. In this mode you can save and read the readings in a measurement or time sequence. The Sequence mode is for maintenance tasks with multiple power systems and battery strings. Before a task starts, users can configure a profile for the task for data management and report generation
Threshold and Warning – Users can configure a maximum of 10 sets of thresholds and receive a Pass/ Warning/ Fail indication after each measurement
Intercell Strap Resistance Test and Data Management – Measures the resistance of the intercell connection between batteries in a string. Once the measurements are completed Fluke Battery Management Software version 1.0.69 can now report the strap resistance for a battery string or historical data over time.
AutoHold – When AutoHold is turned on, a reading is captured when it remains stable for 1 second. The reading is then released when a new measurement starts
AutoSave – When AutoSave is turned on, measured values are saved to internal memory automatically after an AutoHold reading is captured