Excluding GST 10%
Excluding GST 10%
Fluke TP38 Slim Reach Test Probes
$48.00Excluding GST 10%
Features
- 0.95in (24mm) tip length (includes insulated part)
- Only 0.16in (4mm) of tip is exposed
- CAT IV 600V & CAT III 1000V safety rating
- 10A rated & UL listed
- 1-year warranty
Available on backorder
Related products
Fluke 1662 – Multifunction Electrical Tester
Excluding GST 10%
A solid, reliable, basic installation tester
- Tests voltage and frequency
- Checks wiring polarity to detect broken N wires
- Measures insulation resistance and loop and line resistance
- Measures motor windings with continuity test
- Calculates prospective earth fault current (PEFC/IK) and prospective short-circuit current (PSC/IK)
Fluke 435-II Three Phase Power Quality Analyzers
Excluding GST 10%
Key features
The Fluke 435-II products are designed for users who need to get to the solution of the power quality problem as quickly as possible so that they can minimize expensive downtime. The measurement process and display of data is optimized to get to the most important information as quickly as possible. Multiple parameters are measured simultaneously and displayed in formats that quickly describe overall power quality health while giving you the detailed information you need to make better maintenance decisions. Data can be quickly accessed as simple digital values, trend graphs that give you fast insight into changes over time, waveforms, phasor diagrams or analyzed and organized into tabular format such as the event data where the magnitude, duration and time stamping enable rapid correlation to the problems you are experiencing in your facility.
Energy loss Calculator—Calculate money lost to energy waste in terms of real dollars.
It’s a simple fact, poor power quality can have a big impact on the bottom line. The Fluke 435-II enables you to identify issues and measure energy loss giving you specific insight into the amount of loss in dollars associated things like effective power and with poor power quality characteristics such as reactive power, unbalance, distortion, or neutral current. The 435-II even offers users the flexibility to input cable length and cable diameter so you can calculate loss due to conductor sizing (Or use AUTO mode if you don’t know your cable specification) and enter up to four unique time-dependent daily rates (kWh) for more accurate calculations. Armed with this critical data users can easily justify the investment necessary to take countermeasures.
Fluke 125B ScopeMeter Oscilloscope
Excluding GST 10%
Features
- Dual-input digital oscilloscope and multimeter
- 20 or 40MHz bandwidth
- 5mV to 200V/div sensitivity
- VDC and true-rms VAC ranges from 500mV to 750V
- 5000 count full scale reading
- Up to 2200V peak (max, min, & peak-to-peak modes)
- 5% FS accuracy (min or max), 10% (peak-to-peak)
- 500 counts full scale reading
- Up to 70MHz frequency for 124B & 125B
- Up to 50MHz for 123B
- Measure resistance, continuity, diode, & capacitance
- CE & CSA approved, CAT IV 600V safety rated
Fluke 810 Vibration Tester
Excluding GST 10%
Features
- Plain-text diagnosis of standard faults:
- Unbalance
- Looseness
- Misalignment
- Bearing failures
- Fault severity (slight, moderate, serious, extreme)
- 200 rpm to 12000 rpm machine rotational speed range
- 5 Hz to 20 kHz Usable frequency bandwidth
- 2.56 kHz to 51.2 kHz sampling rate
- Lithium-ion, 14.8 V, 2.55 Ah battery
- 1/4 VGA, 320 × 240 color display
- Auto ranging
Fluke 190 Series II 500MHz 4 Channel ScopeMeter Oscilloscope
Excluding GST 10%
Features
- Four independent isolated input channels
- 60, 100, 200 and 500 MHz bandwidths
- Sample rate: Up to 2.5 GS/s
- Sample rate resolution: Up to 400 ps
- Deep memory: 10,000 point per trace waveform capture
- CAT III 1000 V / CAT IV 600 V safety rating
- Seven hour, high performance Li-ion batteries
- Battery door for convenient battery access
- Isolated USB ports for memory devices and PC connectivity
Fluke BT-520 Battery Analyzer
Excluding GST 10%
Key features
Fluke BT510 key features:
- Battery Voltage – During the internal resistance test, Fluke Battery Analyzers also measure the voltage of the battery under test
- Discharge Volts – The Discharge mode collects the voltage of each battery multiple times at a user defined interval during a discharge or load test. Users can calculate the time a battery takes to drop to the cut-off voltage and use this time to determine the capacity loss of the battery
- Ripple Voltage Test – Measures unwanted residual ac component of the rectified voltage in dc charging and inverter circuits. Allows users to test ac components in dc charging circuits and find one of the root causes of battery deterioration
- Meter and Sequence Modes – The Meter mode is used for a quick test or troubleshooting. In this mode you can save and read the readings in a measurement or time sequence. The Sequence mode is for maintenance tasks with multiple power systems and battery strings. Before a task starts, users can configure a profile for the task for data management and report generation
- Threshold and Warning – Users can configure a maximum of 10 sets of thresholds and receive a Pass/ Warning/ Fail indication after each measurement
- Intercell Strap Resistance Test and Data Management – Measures the resistance of the intercell connection between batteries in a string. Once the measurements are completed Fluke Battery Management Software version 1.0.69 can now report the strap resistance for a battery string or historical data over time.
- AutoHold – When AutoHold is turned on, a reading is captured when it remains stable for 1 second. The reading is then released when a new measurement starts
- AutoSave – When AutoSave is turned on, measured values are saved to internal memory automatically after an AutoHold reading is captured
Fluke 424D Laser Distance Meter
Excluding GST 10%
Professional-grade, automated endpiece correction, 80m/260ft range
Features
- Reduction of estimation errors
- Range: 80m/260ft
- Max range: 100m (330ft)
- Inclination sensor for taking measurements in hard to reach areas
- Compass provides a “heading” for distance measurement
- Automated endpiece correction
- Advanced laser technology for distance measurement
- Instant measurement with one-button operation
- Quick calculation of area (square footage) and volume
- Minimum/maximum function
- Improved battery life from automatic shut-off feature
- Enhanced Pythagoras calculation
- Tripod mode
- Stake out function
- Audible keypad feedback
- Storage of the last twenty measurements for quick recall of distance
- IP54 protection
Fluke 124B ScopeMeter Oscilloscope
Excluding GST 10%
Features
- Dual-input digital oscilloscope and multimeter
- 20 or 40MHz bandwidth
- 5mV to 200V/div sensitivity
- VDC and true-rms VAC ranges from 500mV to 750V
- 5000 count full scale reading
- Up to 2200V peak (max, min, & peak-to-peak modes)
- 5% FS accuracy (min or max), 10% (peak-to-peak)
- 500 counts full scale reading
- Up to 70MHz frequency for 124B & 125B
- Up to 50MHz for 123B
- Measure resistance, continuity, diode, & capacitance
- CE & CSA approved, CAT IV 600V safety rated