-11%
Previous product
Back to products Fluke Amprobe TL1500 Test Leads $50.00 $45.00
Excluding GST 10%
Next product
Amprobe TL36A Test Leads $41.00 $37.00
Excluding GST 10%
Amprobe TL35B Test Leads
$56.00 $50.00Excluding GST 10%
- Test lead set connects a compatible electrical test meter to a device for testing
- Set includes two lead wires, two threaded test probe tips, and two alligator clips
- Polyvinyl chloride (PVC) insulation
- Threaded alligator clips have 0.60″ jaw opening and teeth that grip the conductor to provide a more secure, hands-free connection than probe tips
Available on backorder
SKU: 3068232 Categories: Amprobe - Test Instruments, Process Calibration
Related products
Fluke 772 Milliamp Process Clamp Meter
Excluding GST 10%
Features
- mA Measurement Range / Accuracy
- 0 to 20.99 mA / 0.2% + 5 counts (clamp)
- 21.0 to 100.0 mA / 1% + 5 counts (clamp)
- 0 to 24 mA / 0.2% + 2 counts (test jacks)
- mA Source Range / Accuracy
- 0 to 24.00 mA 0.2% / + 2 counts
- mA Simulate Range / Accuracy
- 0 to 24.00 mA 0.2% / + 2 counts
- Simultaneously measure mA in-circuit with 24V loop power
- auto-off, backlight timeout extend battery life
Fluke 714B Temperature Calibrator
Excluding GST 10%
Features
- Measure and simulate 17 different thermocouple types
- Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Configurable 0 % and 100 % source settings
- Linear ramp and 25 % step auto ramp
- Dual inputs and backlit display
- Power down settings
- Max voltage applied between terminal and earth: 30V
- Operating temp: 14 to 122°F (-10 to 50°C)
- Hanging tool designed in and included with every unit
Fluke 705 Loop Calibrator
Excluding GST 10%
Key features
- Powerful loop calibrator that provides a very cost effective, integrated solution for calibration, repair, and maintenance of milliamp loops
- Provides simultaneous mA and % readout for quick, easy interpretation of readings.
- Delivers mA accuracy of 0.02%
- Features push button 25% steps for fast, easy linearity checks
Fluke 771 Milliamp Process Clamp Meter
Excluding GST 10%
Features
- 0.2% or reading + 5 counts accuracy at -20.99 mA to 20.99 mA
- 1% or reading + 5 counts accuracy at -21.0 mA to -99.9 mA and 21.0 mA to 99.9 mA
- 0.177 in or 4.5mm max diameter of measurable conductor
- -10° to 55°C operating temperature
- IP40 rating
Fluke FLUKE-729/750SW BU 729 Automatic Pressure Calibrator and DPC/TRACK2 Software Bundle
$18,788.00
Excluding GST 10%
Features
- Automatic pressure generation and regulation to 300 psi
- Easily document the process using onboard test templates
- Automatic internal fine-pressure adjustment
- Measure, source and simulate 4 to 20 mA signals
- Build instrumentation maintenance routes and load to Fluke 729 Automatic Pressure Calibrators
- Select downloaded tasks in the field configured to match field the instruments being calibrated
- Upload calibration results with field documented calibrations
- Track asset and loop configurations, allowing associated items to be managed as a group or individually
- Graphical user interface featuring DPC/TRACK Explorer. Use DPC/TRACK Explorer to easily navigate through all of the records and view calibrations that are coming due
Applications
- Oil & Gas
- Food & Beverage
- Water/Wastewater
- Pharmaceuticals
-10%
Close
Fluke 725 Multifunction Process Calibrator
Excluding GST 10%
Features
- Up to 30V and 24mA DC
- 0 to 3200Ω resistance
- Up to 10kHz frequency
- 1V peak-to-peak-minimum senitivity
- Combine with a 750P module for pressure
- Store frequently used test setups for later use
Fluke 712B RTD Temperature Calibrator
Excluding GST 10%
Features
- Measure and simulate (13) different RTD types and resistance
- Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Configurable 0 % and 100 % source settings
- Linear ramp and 25 % step auto ramp
- Dual inputs and backlit display
- Power down settings
- Max voltage applied between terminal and earth: 30V
- Operating temp: 14 to 122°F (-10 to 50°C)
Fluke 773 Milliamp Process Clamp Meter
Excluding GST 10%
Key features
- Loop calibrator that measures 4 to 20 mA signals without breaking the loop
- Features best in class 0.2% accuracy
- Sources 4 to 20 mA signals for testing control system I/O or I/Ps
- Delivers 0.01 mA resolution and sensitivity
- Measures DC voltage to verify 24V power supplies or voltage I/O signals