Fluke 6331/7321/7341/7381 Deep-Well Compact Baths
- 457 mm (18 in) of depth with just 15.9 liters (4.2 gal) of fluid
- Perfect for liquid-in-glass thermometers with optional LIG kit
- Fast, quiet, compact (yet deep!), and economical
Fluke 6330/7320/7340/7380 Compact Temperature Calibration Baths
- Stability and uniformity each better than ±0.008°C
- Metrology-level performance in lab-friendly sizes
- Convenient use on benchtops or on matching carts
Fluke 742A Resistance Standards
- Small and rugged resistance calibrators
- No oil or air baths required
- 18° to 28° C operating range
- Six-month stability to 2.5 ppm
- Supplied with temperature characterization
Fluke 5430 Standard AC/DC Resistors
- Long-term stability better than 2 ppm/year (< 1 ppm typical)
- Traceable AC and DC calibrations available
- National lab design proven for more than 25 years
Fluke 1594A, 1595A Super-Thermometers
- Calibrate SPRTs, PRTs, RTDs and thermistors (0 Ω to 500 k Ω)
- Accuracy as good as 0.06 ppm (0.000015 °C)
- “Ratio Self-Calibration” verifies and calibrates resistance ratio accuracy
- Automatic zero-power measurements calculate thermometer probe self-heating
- Temperature-controlled internal reference resistors
- Calibrated sensing current lowers overall instrument uncertainty
- Four input channels on the front panel accept sensors under test or external references
- Two dedicated external reference input channels on the rear panel
- Standby current reduces transient effects when scanning between channels
- Channel Select keys turn measurement mode on or off at the touch of a button
- Sample rates as fast as one second
- USB data transfer and computer control
- Remote view and device control via Ethernet
- Compatible with MET/TEMP II automated calibration software and LogWare II multichannel, real-time data acquisition software
Fluke 7196B LN₂ Comparison Calibrator
- Low-cost calibrations to –196°C
- Simple to use
- Uncertainty less than 2 mK
Fluke 9260 Mini Fixed-Point Cell Furnace
- Good introduction to fixed-point calibration
- User friendly and inexpensive
Fluke 9230 Gallium Cell Maintenance Apparatus
- One week plateau duration
- No hassle automatic realizations
- Used daily in our Primary Lab
Fluke 9210 Mini Triple Point of Water Maintenance Apparatus
- Easy preprogrammed realization
- Inexpensive fixed-point solution
- Training takes a few hours
Fluke 9117 Annealing Furnace
- Guards against contamination
- Anneals both SPRTs and HTPRTs
- Fully programmable
Fluke 9114, 9115A, 9116A Freeze-point furnaces
- Designed to extend plateaus
- High-stability OEM controllers, RS-232 included
- External cooling coils
Fluke 7312 Triple Point of Water Maintenance Bath
- Maintains TPW cells for up to six weeks
- Optional immersion freezer for simple cell freezing
- Independent cutout circuit protects cells from breaking