Fluke 729/750SW BU 729 Automatic Pressure Calibrator and DPC/TRACK2 Software Bundle
Features
- Automatic pressure generation and regulation to 300 psi
- Easily document the process using onboard test templates
- Automatic internal fine-pressure adjustment
- Measure, source and simulate 4 to 20 mA signals
- Build instrumentation maintenance routes and load to Fluke 729 Automatic Pressure Calibrators
- Select downloaded tasks in the field configured to match field the instruments being calibrated
- Upload calibration results with field documented calibrations
- Track asset and loop configurations, allowing associated items to be managed as a group or individually
- Graphical user interface featuring DPC/TRACK Explorer. Use DPC/TRACK Explorer to easily navigate through all of the records and view calibrations that are coming due
Applications
- Oil & Gas
- Food & Beverage
- Water/Wastewater
- Pharmaceuticals
Fluke 750P00 Pressure Module
Specifications
- Parameter/Range:0 to 1 in H2O (0 to 2.5 mBar)
- Burst Rating6: 30X
- Hi Side Media2: Dry Air
- Lo Side Media2: Dry Air
- Reference Uncertainty4: ± 0.15 %
- Total Uncertainty 1-year (15-35°C): ± 0.3 %
- Total Uncertainty 1-year1: ± 0.35 %
- Total Uncertainty 6-month (15-35°C): ± 0.25 %
- Total Uncertainty 6-month1: ± 0.30 %
Fluke 750P01 Differential Pressure Module, 0-25 mBar, 3X Burst Rating
Features
- Parameter/Range:0 to 10 in H2O (0 to 25 mBar)
- Burst Rating6: 3x
- Hi Side Media2: Dry Air
- Lo Side Media2: Dry Air
- Reference Uncertainty4: ± 0.1%
- Total Uncertainty 1-year (15-35°C): ± 0.2%
- Total Uncertainty 1-year1: ± 0.3%
- Total Uncertainty 6-month (15-35°C): ± 0.15%
- Total Uncertainty 6-month1: ± 0.25%
Fluke 750P01EX Pressure Module, 0-10 in H20 DIFF
Features
- Digital communication eliminates errors due to poor connections and electrical interference
- The modules are inherently temperature compensated from 0 to 50°C (32 to 122°F)
- The modules are fully interchangeable because all measurements are completed in the pressure module itself and then communicated to the calibrator in digitized form
- Modules are calibrated independently of the calibrator, and can be used with any 718Ex or 725Ex calibrator
- Each module has its own serial number to maintain independent traceability
- Rugged construction, urethane over molding protects against shock if dropped and seals against dirt, dust, and moisture ingress
- Pressure connections are ⅛” NPT female, easily converted using adapter set
- ¼” NPT Male, ¼” BSP/ISO and M20 male adapters are provided with each pressure module
- Convenient setup, one-meter cable between the pressure module and calibrator reduces the length of connecting tubing to the pressure source
- Three-year warranty, best in class compared to competitors one year warranty
- Added IEC-Ex certification for compliance in extended geographies
Comparing pressure module specifications, it is important to compare both the temperature range the time period the specifications apply. Matching the pressure range to the application is critical for best performance in performing a calibration.
Applications
- Instrument Maintenance
- Control Systems
- Safety Systems
- Process and Environmental Monitors
Fluke 750P02 Pressure Module
Specifications
- Parameter/Range:0 to 1 psi (0 to 70 mBar)
- Burst Rating6:3x
- Hi Side Media2:Dry Air
- Lo Side Media2:Dry Air
- Reference Uncertainty4:± 0.050%
- Total Uncertainty 1-year (15-35°C):± 0.1%
- Total Uncertainty 1-year1:± 0.15%
- Total Uncertainty 6-month (15-35°C):± 0.075%
- Total Uncertainty 6-month1:± 0.125%
Fluke 750P03 Pressure Module
Specifications
- Parameter/Range:0 to 5 psi (0 to 350 mBar
- Burst Rating6:3x
- Hi Side Media2:Dry Air
- Lo Side Media2:Dry Air
- Reference Uncertainty4:± 0.02%
- Total Uncertainty 1-year (15-35°C):± 0.04%
- Total Uncertainty 1-year1:± 0.05%
- Total Uncertainty 6-month (15-35°C):± 0.035%
- Total Uncertainty 6-month1:± 0.04%
Fluke 750P04 Pressure Module
Specifications
- Parameter/Range:0 to 15 psi (0 to 1 bar)
- Burst Rating6:3x
- Hi Side Media2:Dry Air
- Lo Side Media2:Dry Air
- Reference Uncertainty4:± 0.0175%
- Total Uncertainty 1-year (15-35°C):± 0.035%
- Total Uncertainty 1-year1:± 0.045%
- Total Uncertainty 6-month (15-35°C):± 0.03%
- Total Uncertainty 6-month1:± 0.04%
Fluke 750P05 Gauge Pressure Module, 0-2 Bar, 4X Burst Rating
Features
- Parameter/Range:0 to 30 psi (0 to 2 bar)
- Burst Rating6:4x
- Hi Side Media2:316 SS
- Lo Side Media2:N/A
- Reference Uncertainty4:± 0.0175%
- Total Uncertainty 1-year (15-35°C):± 0.035%
- Total Uncertainty 1-year1:± 0.045%
- Total Uncertainty 6-month (15-35°C):± 0.03%
- Total Uncertainty 6-month1:± 0.04%
Fluke 750P05EX Pressure Module, 0-30 PSIG
Features
- Digital communication eliminates errors due to poor connections and electrical interference
- The modules are inherently temperature compensated from 0 to 50°C (32 to 122°F)
- The modules are fully interchangeable because all measurements are completed in the pressure module itself and then communicated to the calibrator in digitized form
- Modules are calibrated independently of the calibrator, and can be used with any 718Ex or 725Ex calibrator
- Each module has its own serial number to maintain independent traceability
- Rugged construction, urethane over molding protects against shock if dropped and seals against dirt, dust, and moisture ingress
- Pressure connections are ⅛” NPT female, easily converted using adapter set
- ¼” NPT Male, ¼” BSP/ISO and M20 male adapters are provided with each pressure module
- Convenient setup, one-meter cable between the pressure module and calibrator reduces the length of connecting tubing to the pressure source
- Three-year warranty, best in class compared to competitors one year warranty
- Added IEC-Ex certification for compliance in extended geographies
Comparing pressure module specifications, it is important to compare both the temperature range the time period the specifications apply. Matching the pressure range to the application is critical for best performance in performing a calibration.
Fluke 750P06 Gauge Pressure Module, 0-7 Bar, 4X Burst Rating
Features
- Parameter/Range:0 to 100 psi (0 to 7 bar)
- Burst Rating6:4X
- Hi Side Media2:316 SS
- Lo Side Media2:N/A
- Reference Uncertainty4:± 0.0175%
- Total Uncertainty 1-year (15-35°C):± 0.035%
- Total Uncertainty 1-year1:± 0.045%
- Total Uncertainty 6-month (15-35°C):± 0.03%
- Total Uncertainty 6-month1:± 0.04%
Applications
- Pressure instrument calibration
- Petro-Chemical
- Oil and Gas
- Pharmaceutical
- Water and wastewater
- Food and Beverage
- Power Generation
Fluke 750P06EX Pressure Module, 0-100 PSIG
Features
- Digital communication eliminates errors due to poor connections and electrical interference
- The modules are inherently temperature compensated from 0 to 50°C (32 to 122°F)
- The modules are fully interchangeable because all measurements are completed in the pressure module itself and then communicated to the calibrator in digitized form
- Modules are calibrated independently of the calibrator, and can be used with any 718Ex or 725Ex calibrator
- Each module has its own serial number to maintain independent traceability
- Rugged construction, urethane over molding protects against shock if dropped and seals against dirt, dust, and moisture ingress
- Pressure connections are ⅛” NPT female, easily converted using adapter set
- ¼” NPT Male, ¼” BSP/ISO and M20 male adapters are provided with each pressure module
- Convenient setup, one-meter cable between the pressure module and calibrator reduces the length of connecting tubing to the pressure source
- Three-year warranty, best in class compared to competitors one year warranty
- Added IEC-Ex certification for compliance in extended geographies
Comparing pressure module specifications, it is important to compare both the temperature range the time period the specifications apply. Matching the pressure range to the application is critical for best performance in performing a calibration.
Applications
- Instrument Maintenance
- Control Systems
- Safety Systems
- Process and Environmental Monitors
Fluke 750P07 Gauge Pressure Module, 0-35 Bar, 4X Burst Rating
Features
- Parameter/Range:0 to 500 psi (0 to 35 bar)
- Burst Rating6:4X
- Hi Side Media2:316 SS
- Lo Side Media2:N/A
- Reference Uncertainty4:± 0.0175%
- Total Uncertainty 1-year (15-35°C):± 0.035%
- Total Uncertainty 1-year1:± 0.045%
- Total Uncertainty 6-month (15-35°C):± 0.03%
- Total Uncertainty 6-month1:± 0.04%
Applications
- Pressure instrument calibration
- Petro-Chemical
- Oil and Gas
- Pharmaceutical
- Water and wastewater
- Food and Beverage
- Power Generation