Showing 1–24 of 70 results

Show sidebar
Close

Fluke 1529 Chub-E4 Standards Thermometer

  • Four channels for PRTs, thermistors, and thermocouples
  • Displays eight user-selected data fields from any channel
  • Logs up to 8,000 readings with date and time stamps
  • Battery provides eight hours of continuous operation
-2%
Close

Fluke 1551A-12 Intrinsically Safe Stik Thermometer, 12″

$1,199.00
Excluding GST 10%

Features

  • Intrinsically-safe, battery operated, portable reference thermometer
  • Provides accuracy of ±0.09°F (±0.05°C) over full range
  • Features intrinsically-safe operation (ATEX and IECEx compliant)
  • Measures -58 to 320°F (-50 to 160°C)
  • Provides user-configurable temperature with Trend/Stability indicator
  • Displays temperature in °C or °F
  • Delivers 300-hour battery life
  • Shows percent battery-life and low-battery indicators
Close

Fluke 1560 Black Stack Thermometer Readout

  • Reads SPRTs, RTDs, thermistors, and thermocouples
  • Any configuration you like up to eight modules
  • High-accuracy reference thermometer (to ±0.0013°C)
  • Automates precision data acquisition
Close

Fluke 1586A Super-DAQ Precision Temperature Scanner

  • Measure thermocouples, PRTs, thermistors, dc voltage, dc current, and resistance
  • Best-in-class temperature measurement accuracy
    • PRTs ± 0.005 °C (using external DAQ‑STAQ Multiplexer)
    • Thermocouples: ± 0.5 °C (using High-Capacity Module and internal CJC)
    • Thermistors: ± 0.002 °C
  • Input channels: Up to 40 isolated universal inputs
  • Flexible configuration: Internal High-Capacity Module and/or DAQ-STAQ Multiplexer
  • Selectable scan speed: Up to 10 channels per second
  • Four modes of operation: Scan, Monitor, Measure, Digital Multimeter (DMM)
  • Real-time color trending: Chart up to four channels simultaneously
  • 6 1/2 digit display resolution for dc voltage, dc current, and resistance
  • Current reversal minimizes thermoelectric effects, improving PRT/RTD measurement accuracy
  • Automated sensor calibration: Control Fluke Calibration temperature sources such as dry-wells or micro-baths for automated calibration routines
  • Data storage: Records up to 20 MB of data and setup files to internal non-volatile memory or to an external USB drive. Transfer data to a PC using the USB drive or LAN connection and view data in Microsoft® Excel
  • Data security: Administrator and user profiles for protecting settings and ensuring test traceability
  • Mx + B scaling and channel offset zero function
  • Alarms: Two independent, user-defined alarms for each channel indicate when an upper or lower range has been exceeded
  • Supported by TQSoft and TQAero thermal validation software for FDA 21 CFR Part 11 and AMS 2750 compliant data collection
Close

Fluke 1594A, 1595A Super-Thermometers

  • Calibrate SPRTs, PRTs, RTDs and thermistors (0 Ω to 500 k Ω)
  • Accuracy as good as 0.06 ppm (0.000015 °C)
  • “Ratio Self-Calibration” verifies and calibrates resistance ratio accuracy
  • Automatic zero-power measurements calculate thermometer probe self-heating
  • Temperature-controlled internal reference resistors
  • Calibrated sensing current lowers overall instrument uncertainty
  • Four input channels on the front panel accept sensors under test or external references
  • Two dedicated external reference input channels on the rear panel
  • Standby current reduces transient effects when scanning between channels
  • Channel Select keys turn measurement mode on or off at the touch of a button
  • Sample rates as fast as one second
  • USB data transfer and computer control
  • Remote view and device control via Ethernet
  • Compatible with MET/TEMP II automated calibration software and LogWare II multichannel, real-time data acquisition software
-10%
Close

Fluke 1919047 Calibration Cable

$423.00
Excluding GST 10%

For use with 724, 725 and 726 Temperature Calibrators.

Close

Fluke 2100 and 2200 Benchtop Temperature Controllers

  • Most stable temperature controllers available
  • Resolution as high as 0.00018°C
  • RS-232 interface included for automating applications
Close

Fluke 4180-256 – Precision IR Calibrators IR Calibrator

$15,055.00
Excluding GST 10%
  • Calibrated radiometrically for meaningful, consistent results.
  • Accredited calibration included
  • Accurate, reliable performance from –15 °C to 500 °C
  • Large target size of 152 mm (6 in) is required for calibrating most thermometers.
  • Light instrument weight of 8.6 kg (19 lbs) makes it easy to lift and carry.
  • Intuitive, easy-to-read display that indicates when temperature is stable.
-9%
Placeholder
Close

Fluke 4180-PURGEBOX Purge-Box Plexiglas for 4180 Models

$2,990.00
Excluding GST 10%

What’s included with the Fluke 4180-PURGEBOX

  • Fluke 4180-PURGEBOX Purge-Box Plexiglas for 4180 Models
Placeholder
Close

Fluke 5430 Standard AC/DC Resistors

  • Long-term stability better than 2 ppm/year (< 1 ppm typical)
  • Traceable AC and DC calibrations available
  • National lab design proven for more than 25 years
Close

Fluke 5606 Full Immersion PRT

  • 5606: -200 °C to 160 °C
  • Calibration accuracy of ± 0.05 °C
  • Transition junction and lead wires can withstand full PRT temperature range
  • Unique probe seal of 5606 prevents ingress of moisture
  • NVLAP-accredited calibration
Close

Fluke 5610, 5611, 5611T, 5665 Temperature Probes, Reference Thermistor Probes

  • Temperature probes with short-term accuracy to ± 0.01 °C; one-year drift < ± 0.01 °C
  • Accredited NVLAP calibration optional
  • Flexible PTFE and silicone coated fast-response models
  • Rugged polished stainless steel sheaths
Close

Fluke 5615 Secondary Reference Temperature Standards

  • Affordable wide-range accuracy
  • Calibrated accuracy ± 0.012 °C at 0 °C
  • Reference-grade platinum sensing element
  • NVLAP-accredited calibration included, lab code 200706-0
Close

Fluke 5618B Small Diameter Industrial RTD

  • Small diameter sheath, 3.2mm (0.125 in)
  • Excellent stability
  • Includes ITS-90 coefficients
  • NVLAP-accredited calibrated from –200°C to 500°C, lab code 200706-0
Placeholder
Close

Fluke 5622 Fast Response Platinum Resistance Thermometers (PRTs)

  • Time constants as fast as 0.4 seconds
  • NVLAP-accredited calibration, lab code 200348-0
  • Small probe diameters ranging from 0.5 mm to 3.2 mm
Placeholder
Close

Fluke 5623B Precision RTD Freezer Probe

  • Fully immersible probe assembly to –100°C
  • NVLAP-accredited calibration, lab code 200706-0, and ITS-90 coefficients included
  • Accuracy to ±0.05°C over the full range
Close

Fluke 5624 Platinum Resistance Thermometer to 1000 °C

  • Temperature range of 0°C to 1000°C
  • Accuracy (includes short-term stability and calibration uncertainty) of ±0.05°C to 962°C
  • Long-term drift of 0.01°C at 0°C after 100 hours at 1000°C
  • Designed by Fluke Calibration’s primary standards design team
Close

Fluke 5626, 5628 Secondary Standard PRTs

  • Range to 661°C
  • Meets all ITS-90 requirements for resistance ratios
  • Rtp drift < 20 mK after 500 hours at 661°C
  • Calibrated accuracy of ± 0.006 °C at 0 °C
Close

Fluke 5627A Precision Thermometer, RTD Temperature Probe

  • Vibration and shock resistant
  • NVLAP-accredited calibration included, lab code 200706-0
Close

Fluke 5640 Series Thermistor Standards Probes

  • Accuracy to ± 0.001 °C
  • Affordable system accuracy to ± 0.004 °C or better
  • NIST-traceable calibration included from manufacturer; accredited calibration from Fluke Calibration optional
Close

Fluke 5681, 5683, 5684, and 5685 Quartz-Sheath SPRTs

  • Drift rates as low as 0.0005 K
  • Proprietary gas mixture ensures high stability
  • Most experienced SPRT design team in the business
Close

Fluke 5686-B Glass Capsule SPRT

  • Temperatures from –260 °C (13 K) to 232 °C
  • Stability typically 0.001 °C over 100 °C range
  • Miniature capsule package eliminates stem conduction
Close

Fluke 5698-25 Working Standard SPRT

  • Conforms to ITS-90 SPRT guidelines
  • Drift rate typically 0.003 °C
  • Calibration options by fixed point
  • Unmatched performance-to-price-ratio
Close

Fluke 5699 High-Temperature Metal-Sheath SPRT

  • Range to aluminum point (660 °C )
  • Inconel™ and platinum sheaths guard against contamination
  • Less than 8 mK/year drift
  • Many calibration options available including by fixed point
  • Fifth wire provides shield ground