Fluke 1529 Chub-E4 Standards Thermometer
- Four channels for PRTs, thermistors, and thermocouples
- Displays eight user-selected data fields from any channel
- Logs up to 8,000 readings with date and time stamps
- Battery provides eight hours of continuous operation
Fluke 1551A-12 Intrinsically Safe Stik Thermometer, 12″
Features
- Intrinsically-safe, battery operated, portable reference thermometer
- Provides accuracy of ±0.09°F (±0.05°C) over full range
- Features intrinsically-safe operation (ATEX and IECEx compliant)
- Measures -58 to 320°F (-50 to 160°C)
- Provides user-configurable temperature with Trend/Stability indicator
- Displays temperature in °C or °F
- Delivers 300-hour battery life
- Shows percent battery-life and low-battery indicators
Fluke 1560 Black Stack Thermometer Readout
- Reads SPRTs, RTDs, thermistors, and thermocouples
- Any configuration you like up to eight modules
- High-accuracy reference thermometer (to ±0.0013°C)
- Automates precision data acquisition
Fluke 1586A Super-DAQ Precision Temperature Scanner
- Measure thermocouples, PRTs, thermistors, dc voltage, dc current, and resistance
- Best-in-class temperature measurement accuracy
- PRTs ± 0.005 °C (using external DAQ‑STAQ Multiplexer)
- Thermocouples: ± 0.5 °C (using High-Capacity Module and internal CJC)
- Thermistors: ± 0.002 °C
- Input channels: Up to 40 isolated universal inputs
- Flexible configuration: Internal High-Capacity Module and/or DAQ-STAQ Multiplexer
- Selectable scan speed: Up to 10 channels per second
- Four modes of operation: Scan, Monitor, Measure, Digital Multimeter (DMM)
- Real-time color trending: Chart up to four channels simultaneously
- 6 1/2 digit display resolution for dc voltage, dc current, and resistance
- Current reversal minimizes thermoelectric effects, improving PRT/RTD measurement accuracy
- Automated sensor calibration: Control Fluke Calibration temperature sources such as dry-wells or micro-baths for automated calibration routines
- Data storage: Records up to 20 MB of data and setup files to internal non-volatile memory or to an external USB drive. Transfer data to a PC using the USB drive or LAN connection and view data in Microsoft® Excel
- Data security: Administrator and user profiles for protecting settings and ensuring test traceability
- Mx + B scaling and channel offset zero function
- Alarms: Two independent, user-defined alarms for each channel indicate when an upper or lower range has been exceeded
- Supported by TQSoft and TQAero thermal validation software for FDA 21 CFR Part 11 and AMS 2750 compliant data collection
Fluke 1594A, 1595A Super-Thermometers
- Calibrate SPRTs, PRTs, RTDs and thermistors (0 Ω to 500 k Ω)
- Accuracy as good as 0.06 ppm (0.000015 °C)
- “Ratio Self-Calibration” verifies and calibrates resistance ratio accuracy
- Automatic zero-power measurements calculate thermometer probe self-heating
- Temperature-controlled internal reference resistors
- Calibrated sensing current lowers overall instrument uncertainty
- Four input channels on the front panel accept sensors under test or external references
- Two dedicated external reference input channels on the rear panel
- Standby current reduces transient effects when scanning between channels
- Channel Select keys turn measurement mode on or off at the touch of a button
- Sample rates as fast as one second
- USB data transfer and computer control
- Remote view and device control via Ethernet
- Compatible with MET/TEMP II automated calibration software and LogWare II multichannel, real-time data acquisition software
-10%
Close
Fluke 1919047 Calibration Cable
For use with 724, 725 and 726 Temperature Calibrators.
Fluke 2100 and 2200 Benchtop Temperature Controllers
- Most stable temperature controllers available
- Resolution as high as 0.00018°C
- RS-232 interface included for automating applications
Fluke 4180-256 – Precision IR Calibrators IR Calibrator
- Calibrated radiometrically for meaningful, consistent results.
- Accredited calibration included
- Accurate, reliable performance from –15 °C to 500 °C
- Large target size of 152 mm (6 in) is required for calibrating most thermometers.
- Light instrument weight of 8.6 kg (19 lbs) makes it easy to lift and carry.
- Intuitive, easy-to-read display that indicates when temperature is stable.
-9%
Close
Fluke 4180-PURGEBOX Purge-Box Plexiglas for 4180 Models
What’s included with the Fluke 4180-PURGEBOX
- Fluke 4180-PURGEBOX Purge-Box Plexiglas for 4180 Models
Fluke 5430 Standard AC/DC Resistors
- Long-term stability better than 2 ppm/year (< 1 ppm typical)
- Traceable AC and DC calibrations available
- National lab design proven for more than 25 years
Fluke 5606 Full Immersion PRT
- 5606: -200 °C to 160 °C
- Calibration accuracy of ± 0.05 °C
- Transition junction and lead wires can withstand full PRT temperature range
- Unique probe seal of 5606 prevents ingress of moisture
- NVLAP-accredited calibration
Fluke 5610, 5611, 5611T, 5665 Temperature Probes, Reference Thermistor Probes
- Temperature probes with short-term accuracy to ± 0.01 °C; one-year drift < ± 0.01 °C
- Accredited NVLAP calibration optional
- Flexible PTFE and silicone coated fast-response models
- Rugged polished stainless steel sheaths
Fluke 5615 Secondary Reference Temperature Standards
- Affordable wide-range accuracy
- Calibrated accuracy ± 0.012 °C at 0 °C
- Reference-grade platinum sensing element
- NVLAP-accredited calibration included, lab code 200706-0
Fluke 5618B Small Diameter Industrial RTD
- Small diameter sheath, 3.2mm (0.125 in)
- Excellent stability
- Includes ITS-90 coefficients
- NVLAP-accredited calibrated from –200°C to 500°C, lab code 200706-0
Fluke 5622 Fast Response Platinum Resistance Thermometers (PRTs)
- Time constants as fast as 0.4 seconds
- NVLAP-accredited calibration, lab code 200348-0
- Small probe diameters ranging from 0.5 mm to 3.2 mm
Fluke 5623B Precision RTD Freezer Probe
- Fully immersible probe assembly to –100°C
- NVLAP-accredited calibration, lab code 200706-0, and ITS-90 coefficients included
- Accuracy to ±0.05°C over the full range
Fluke 5624 Platinum Resistance Thermometer to 1000 °C
- Temperature range of 0°C to 1000°C
- Accuracy (includes short-term stability and calibration uncertainty) of ±0.05°C to 962°C
- Long-term drift of 0.01°C at 0°C after 100 hours at 1000°C
- Designed by Fluke Calibration’s primary standards design team
Fluke 5626, 5628 Secondary Standard PRTs
- Range to 661°C
- Meets all ITS-90 requirements for resistance ratios
- Rtp drift < 20 mK after 500 hours at 661°C
- Calibrated accuracy of ± 0.006 °C at 0 °C
Fluke 5627A Precision Thermometer, RTD Temperature Probe
- Vibration and shock resistant
- NVLAP-accredited calibration included, lab code 200706-0
Fluke 5640 Series Thermistor Standards Probes
- Accuracy to ± 0.001 °C
- Affordable system accuracy to ± 0.004 °C or better
- NIST-traceable calibration included from manufacturer; accredited calibration from Fluke Calibration optional
Fluke 5681, 5683, 5684, and 5685 Quartz-Sheath SPRTs
- Drift rates as low as 0.0005 K
- Proprietary gas mixture ensures high stability
- Most experienced SPRT design team in the business
Fluke 5686-B Glass Capsule SPRT
- Temperatures from –260 °C (13 K) to 232 °C
- Stability typically 0.001 °C over 100 °C range
- Miniature capsule package eliminates stem conduction
Fluke 5698-25 Working Standard SPRT
- Conforms to ITS-90 SPRT guidelines
- Drift rate typically 0.003 °C
- Calibration options by fixed point
- Unmatched performance-to-price-ratio
Fluke 5699 High-Temperature Metal-Sheath SPRT
- Range to aluminum point (660 °C )
- Inconel™ and platinum sheaths guard against contamination
- Less than 8 mK/year drift
- Many calibration options available including by fixed point
- Fifth wire provides shield ground