Showing 145–156 of 284 results

Show sidebar
Close

Fluke i200 AC Current Clamp

$367.00
Excluding GST 10%
  • Fluke I200 Offers

    Features

    • Companion to a DMM for measuring up to 200 A AC
    • 1 mA per Amp output guarantees easy reading on you meter
    • Take accurate current readings without breaking the circuit
    • Max. conductor Ø 0.8″ (20 mm)
    • CAT III 600 V safety rating
Close

Fluke i2000 Flex AC Current Clamp

$651.00
Excluding GST 10%

Features

  • AC RMS current ranges with ±1% accuracy
    • 20A (100mV/A output)
    • 200A (10mV/A output)
    • 2000A (1mV/A output)
  • 10Hz to 20kHz frequency
  • 100kΩ minimum load impedance
  • 178mm maximum conductor diameter
  • CAT III 600V safety rating
Close

Fluke i2000 FLEX Flexible AC Current Clamp

$846.00
Excluding GST 10%

Features

  • Three ranges: 20 A, 200 A & 2000 A, 100 mV/A, 10 mV/A & 1 mV/A output
  • Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
  • Maximum conductor diameter 7″ (178 mm)
  • CAT III 600 V safety rating
Close

Fluke i200s AC Current Clamp

$562.00
Excluding GST 10%

Features

  • Take current readings without breaking the circuit
    • 1.5% + 0.5A (48 to 65Hz) accuracy
  • Switchable ranges
    • 20A (100mV/A output)
    • 200A (10mV/A output)
  • 240A maximum non-destructive current
  • 40Hz to 10kHz useable frequency
  • 20mm maximum conductor diameter
  • CAT III 600V safety rating
Close

Fluke i30 AC/DC Current Clamp

$1,074.00
Excluding GST 10%
  • AC current range: 30mA to 20Arms
  • DC current range: 30mA to 30A DC
  • Frequency range: DC to 20 kHz (-0.5 dB)
  • Safety rating(s): CAT III 300V
Close

Fluke i3000 Flex AC Current Clamp, 4 Pack

$2,858.00
Excluding GST 10%
  • Three ranges: 30 A, 300 A & 3000 A, 1, 10 or 100 mV/A output
  • Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
  • Maximum conductor diameter 178 mm
  • CAT III 600V safety rating
Close

Fluke i3000s AC Current Clamp

$1,468.00
Excluding GST 10%

Features

  • For measurement on power distribution systems
  • Current ranges with 2% + 2A basic accuracy
    • 1 to 30A (10mV/A output)
    • 1 to 300A (1mV/A output)
    • 1 to 3000A (0.1mV/A output)
  • 4000A maximum non-destructive current
  • 10Hz to 100kHz usable frequency
  • 64mm maximum conductor diameter
  • CAT III 600V safety rating
  • 1-year warranty
Close

Fluke i3000s Flex AC Current Clamp

$1,148.00
Excluding GST 10%

Features

  • AC RMS current ranges with ±1% accuracy
    • 1 to 30A (100mV/A output)
    • 1 to 300A (10mV/A output)
    • 1 to 3000A (1mV/A output)
  • 10Hz to 50kHz frequency
  • 100kΩ minimum load impedance
  • CAT III 600V safety rating
Close

Fluke i3000s Flex-24 Flexible AC Current Probe, 24 inch length

$1,235.00
Excluding GST 10%
  • Three ranges: 30 A, 300 A & 3000 A, 1, 10 or 100 mV/A output
  • Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
  • Maximum conductor diameter 178 mm
  • CAT III 600V safety rating
Close

Fluke i3000s Flex-36 AC Current Clamp, 36 inch length

$1,447.00
Excluding GST 10%

Fluke I3000S-FLEX-36 Offers

The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.

Features

  • Three Ranges: 30A, 300A, and 3000A with 1, 10, or 100 mV/A output
  • Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
  • Maximum conductor diameter 178 mm (7 in.)
  • CAT III 600 V safety rating
Close

Fluke i30s AC/DC Current Clamp

$1,247.00
Excluding GST 10%

Features

  • Usable current range
    • 5mA to 30A DC
    • 30mA to 20A AC RMS
  • ±1% of reading ±2mA (@25°C)
  • 100mV/A output sensitivity
  • ±1mA resolution
  • 1.4in crest factor
  • >100kΩ load impedance
  • 100kHz frequency
Close

Fluke i310S AC/DC Current Clamp

$992.00
Excluding GST 10%
  • Current Ranges: 30 A and 300 A ACrms or ±45 A and 450 A DC
  • Measuring Ranges: ±45 A and 450 A
  • Output Sensitivity: 10 mV/A (40 A) to 1 mV/A (400 A)
  • Resolution: ±50 mA (40 A) to ±100 mA (400 A)
  • Load Impedance: > 10 k Ohms and 100 pF
  • Frequency Range (small signal): DC to 20 kHz (- 3 dB)
  • Phase Shift below 1 kHz, < 2 degrees
  • Temperature Coefficient: ±0.1% of reading / ±C
  • Power Supply: 9 V Alkaline