Excluding GST 10%
Excluding GST 10%
Amprobe AT-6010 Advanced Wire Tracer Kit
$1,200.00Excluding GST 10%
-
Amprobe AT-6010 Offers
With the AT-6010 advanced wire tracer kit, it is easier and safer to locate energized and de-energized wires, breakers and fuses. When the transmitter is connected to the circuit, the receiver easily detects the signal in the wires or cables behind walls, ceilings and floors. The transmitter works on energized and de-energized circuits up to 600 V AC/DC in Category I through Category III electrical environments, allowing for work directly on an energized circuit without the need to take equipment offline. The transmitter also features high signal mode for general tracing and a loop mode designed specifically for locating shorts, as well as two optimal tracing frequencies that are automatically activated based on the detected voltage.
Features
- Receiver:
- Tip sensor – to trace wires in tight spaces
- Large black and white LCD screen
- Energized/De-energized indicator
- Signal strength bar graph
- Sensitivity adjustment
- Transmitter:
- Compatible with standard test leads
- Voltage warning indicator
- HI mode for general wire tracing
- Loop mode for finding shorts
- Simple one button operation
- Large LCD Receiver screen with two digit readout, bar graph and sound to easily determine wire location
- Compatible with the CT-400 Signal Clamp accessory for inducing a tracing signal on the cable when there is no access to bare conductors
Applications
- Trace energized and de-energized wires
- Identify breakers and fuses
- Connect to GFCI protected circuits
- Find breaks and opens
- Find shorts
- Trace wires in metal conduit
- Trace non-metallic pipes and conduit
- Trace shielded wires
- Trace underground wires
- Trace low voltage wires and data cables
- Sort bundled wires
- Map a circuit with test leads
- Trace breakers on system with light dimmers
- Receiver:
Available on backorder
Related products
Fluke Amprobe 34XR-A TRMS Digital Multimeter with Temperature
Excluding GST 10%
- Autoranging; display: 3-3/4 digit LCD, 3999 counts with 41-segment analog bar graph
- Display update rate: 2/sec, nominal
- Operating temperature: 0 °C to 45 °C at < 70 % R.H
- True-rms digital multimeter with temperature and backlight
- Overrange indication
- Auto power off to save battery life
- Min/max, data hold and range lock
- Separate door for easy battery and fuse access
- Magne-Grip™ Holster with magnetic hanging strap
Fluke Amprobe ACD-23SW Swivel Clamp Meter
Excluding GST 10%
-
Product Features:
- Performs true-RMS measurement
- 180 degree rotating head for optimal display viewing
- Advanced VoltTect non-contact voltage detection
- Easy to use with slim jaw design and one hand operation
- Measures AC current up to 400A
- Measures AC and DC voltage up to 600V
- Resistance and capacitance measurement
- Audible continuity
- Temperature measurement with type-K thermocouple probe
- Auto and manual ranging respectively offer quick checks and precise measurements
- Accommodates conductors up to 1.18″ (30mm) in diameter
- Auto power off to extend battery life
- Includes data hold function
- Safety rated toCAT III 600 V
Fluke Amprobe 15XP-B Digital Multimeter VolTect
Excluding GST 10%
- Features
- The 15XP-B is the right choice for electronics engineers, technicians and field service
- Autoranging display for faster measurements
- TTL logic test for digital circuits
- Integrated tilt stand for easy bench use
- Diode test for component level troubleshooting
- Data Hold freezes display to “hold” measurement reading
- 750 V AC / 1000 V DC—highest voltage rating in this size of meter
- Special 2000M Ω measurement range
- Battery Life: 200 hours typical with carbon-zinc
- Size: (H x W x D) 155 mm x 72 mm x 32 mm (6.1 x 2.83 x 1.26 IN)
- Safety: CAT II 1000V, CATIII 600V, CE, N10140
Fluke Amprobe ACD-14 TRMS-PLUS Dual Display Digital Clamp Multimeter
Excluding GST 10%
-
Product Features:
- Dual displays allow for simultaneous reading of amperage and voltage
- True-RMS for precise measurement results
- Thin jaws facilitate access in tight measurement spaces
- AC current to 600A
- AC and DC voltage to 600V
- Resistance to 40MΩ
- Capacitance to 3000 µF
- Temperature measurement with K-type thermocouple probe
- Frequency measurement
- In rush current measurement
- Diode test and continuity buzzer
- Micro Amps measurement for testing flame sensors
- Hold and maximum reading functions
- Accommodates conductors up to 28 mm (1.1″) in diameter
- Auto ranging instantly selects correct range
- Auto power off and low battery indication
- Rubber over-molded case
Amprobe ALC-110 Leakage Current Clamp
Excluding GST 10%
-
Product Features:
- Measures:
- Earth and differential leakage currents
- Leakage currents through the earth (PE) conductor
- Appliance current consumption without interruptions to the circuit
- Low influence of external low frequency magnetic fields: @ IN: 3.500 mA – 600.0 mA ≤ 30 A/m, operating class 2
- True-RMS measurements for accuracy when measuring complex, non-sinusoidal waveforms
- Mechanical jaw lock with 1.2 in. (30 mm) opening assures accuracy of low current measurements
- Highest resolution of 0.001 mA while measuring up to 60 A
- Broad frequency range 15 Hz to 1 kHz
- Selectable filters:
- Low Pass 50/60Hz filter to perform measurements on equipment driven by Variable Frequency Drives (VFDs) or affected by high frequency noise
- Appliance Filter to conduct leakage current measurements on appliances
- No filter
- Selectable limits: 0.25 mA, 0.5 mA, 3.5 mA, 10 mA, 12 mA
- Max readings and hold function
- High safety rating: CAT III 600 V
- Battery-saving design with an auto backlight off and auto power off
Applications
- Trace the source of earth leakage current
- Identify intermittent GFCI trips without switching equipment off
- Check a system for an electrical break of insulation where current is flowing to the ground
- Where industrial leakage current testing is required
- Measures:
Amprobe AC50A AC Leakage Clamp Meter
Excluding GST 10%
-
Product Features:
- AC current measurement to 60A
- Leakage current measurement with resolution of 0.01mA
- AC voltage to 400V
- Resistance measurement and continuity beeper
- Min/max control to see largest or smallest values in series of measurements
- Relative value measurement to determine differentials
- Data hold to freeze measurement value on display
- Digital display with analog bargraph
- Jaw opening: 30 mm (1.2 in)
- Auto-power off to save battery life
- Minimum resolution 0.01mA
Amprobe ACD-53NAV CAT IV 1000 A AC True-rms Navigator Clamp Meter
Excluding GST 10%
- True RMS technology improves accuracy in noisy environments
- Measures AC/DC voltage to 1000 V, AC/DC current to 600 A, plus resistance, frequency, capacitance, power and power factor, total harmonics distortion (THD) and individual harmonics from 1 to 25
- Includes inrush current measurement and phase rotation indication for 3-phase motors
- Non-contact voltage detection enhances safety
- Low pass filter enables measuring voltage and frequency on variable frequency drives
- Continuity beeper quickly identifies shorts and opens
- Large backlit digital display with analog bar graph presents the full picture
- Min, max and smart data hold
- Peak hold identifies spikes and transients
- In-jaw flashlight automatically lights when jaws open to illuminate dark panels and junction boxes
- Auto power off conserves battery life
- Maximum jaw opening accommodates large conductors up to 1.45″ (37 mm)
- Rubber overmold body absorbs shocks—drop proof to 4 feet (1.2 m)
- CAT IV-rated AC/DC current clamp meter
Fluke Amprobe 33XR-A Digital Multimeter with Temperature
Excluding GST 10%
-
Product Features:
- Frequency To 40 MHz, Temperature To 1832 F, Capacitance To 4000 microF
- Input Warning Tone When Test Leads Are In Wrong Jack
- 1000V/750V DC/AC
- 10 Amps AC/DC. Fully Safety Fused
- Resistance To 4ohm
- Min/max, relative, peak and data hold
- Auto power off to save battery life
- Separate door for easy battery and fuse access
- Magne-Grip Holster with magnetic hanging strap
- Display: 3-3/4 digit LCD, 3999 counts with 41-segment analog bar graph
- Display update rate: 2/sec, nominal
- Analog bar graph
- Overrange indication
- Operating temperature: 0 °C to 45 °C at < 70 % R.H.
- Storage temperature: -20 °C to 60 °C,
- Input warning tone when test leads are in wrong jack