The Laboratory Environment Monitor (LEM) provides the ability to measure barometric pressure, ambient temperature, relative humidity and air density. The LEM transmits these measurements via an RS-232 or RS-485 interface to a PC. The supplied software can then be used to monitor and log all the above parameters for one or up to eight LEMs, simultaneously.
Fluke 2456-LEM Laboratory Environment Monitor
- Communicates via RS-232 or RS-485
- Includes software to display all parameters in addition to data logging and calibration
- Precision to 0.1 °C, 0.04 inHg (1.3 mbar) and 3 % RH
- Ideal for calibration labs, clean rooms, storage facilities or use with Ruska piston gauges
- Replaces mechanical strip chart recorders
Category: Fluke Calibration Equipment
Related products
Fluke 712B RTD Temperature Calibrator
$2,846.00
Excluding GST 10%
Features
- Measure and simulate (13) different RTD types and resistance
- Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Configurable 0 % and 100 % source settings
- Linear ramp and 25 % step auto ramp
- Dual inputs and backlit display
- Power down settings
- Max voltage applied between terminal and earth: 30V
- Operating temp: 14 to 122°F (-10 to 50°C)
Fluke 787B Process Meter
$2,120.00
Excluding GST 10%
Features
- 400mV up to 1000V voltage range
- Fluke connect
- 20 mA dc current source/measure/simulate
- Simultaneous mA and % of scale readout
- Frequency measurement up to 20 kHz
- Meets IEC 61010 CAT III and 600 V CAT IV standards
- Min/max/average/hold/relative modes
- Diode test and continuity beeper
- -4 to 131°F (-20 to 55°C) operating temp range
Fluke 772 Milliamp Process Clamp Meter
Excluding GST 10%
Features
- mA Measurement Range / Accuracy
- 0 to 20.99 mA / 0.2% + 5 counts (clamp)
- 21.0 to 100.0 mA / 1% + 5 counts (clamp)
- 0 to 24 mA / 0.2% + 2 counts (test jacks)
- mA Source Range / Accuracy
- 0 to 24.00 mA 0.2% / + 2 counts
- mA Simulate Range / Accuracy
- 0 to 24.00 mA 0.2% / + 2 counts
- Simultaneously measure mA in-circuit with 24V loop power
- auto-off, backlight timeout extend battery life
Fluke 9142 – Field Metrology Wells
$10,362.00
Excluding GST 10%
Key Features:
- Lightweight, portable, and fast
- Cool to –25 °C in 15 minutes and heat to 660°C in 15 minutes
- Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
- True reference thermometry with accuracy to ±0.01 °C
- On-board automation and documentation
- Metrology performance in accuracy, stability, uniformity, and loading
Fluke 719Pro Electric Pressure Calibrator
$8,739.00
Excluding GST 10%
Features
- Electric pump for one handed pressure calibration
- Best in class pressure measurement uncertainty of 0.025%
- Measure and source mA with best in class 0.015% accuracy
- Precision pressure adjust vernier for accurate pressure calibration
- Variable release rate bleed valve for easy pressure adjustment
- Programmable pressure calibrator pump limit: eliminates over-pressurization and allows the user to program target pressures for pumping
- Programmable 3-tiered display for maximum flexibility when displaying pressure, temperature, and electrical parameters of your choice
- Display backlight
- Damping, Min/Max, and % error function
- Source mA with simultaneous pressure measurement to test valves and I/Ps
- Simulate mA signals to troubleshoot 4-20 mA loops
- Test pressure switches with built in switch test function
- Power transmitters during test using 24 V loop supply with simultaneous mA measurement
- Precision temperature measurement with the addition of an accessory RTD probe (available as an option)
- Proven cleanout ports reduce pump failures
- Moisture trap included with the unit helps mitigates risk of moisture damage
Applications
- Pressure Instrument Calibration
- Pressure Instrument Maintenance
- Petro-Chemical
- Oil and Gas
- Pharmaceutical
- Water and wastewater
- Food and Beverage
- Power Generation
Fluke 718Ex Pressure Calibrator
$6,663.00
Excluding GST 10%
Features
- ATEX II 1G Ex ia IIC T4 Compliant
- Built-in pressure / vacuum hand pump, with fine adjust vernier and bleed valve
- 30, 100, and 300 psi ranges (2, 7, and 20 bar)
- Pressure measurement to 0.05% of full span, using an internal pressure sensor
- Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules
- Wide range of selectable measurement units for pressure
- Current measurement with 0.02% accuracy and 0.001 mA resolution
- Pressure switch test function
- Min-Max Hold functions
- Compact size and weight
- Simple, push-button user interface
- Rugged and reliable, ideal for field use
Fluke 773 Milliamp Process Clamp Meter
$2,400.00
Excluding GST 10%
Key features
- Loop calibrator that measures 4 to 20 mA signals without breaking the loop
- Features best in class 0.2% accuracy
- Sources 4 to 20 mA signals for testing control system I/O or I/Ps
- Delivers 0.01 mA resolution and sensitivity
- Measures DC voltage to verify 24V power supplies or voltage I/O signals
Fluke 726 Precision Multifunction Process Calibrator
$7,150.00
Excluding GST 10%
Features
- Up to 20V (source), up to 30V (measure)
- 0 to 24mA source and simulate
- Up to 4000Ω resistance
- Frequency up to 15kHz
- RTD and thermocouple compatible
- Combine with a 750P module for pressure
- Memory storage for up to 8 calibration results
- Perform fast linearity tests with auto step & auto ramp
- 24VDC Loop Supply
- 3-year warranty