The Model 2468 Pitot Static Primary Standard is specifically designed for calibrating today’s high performance flight line and Air Data Test Systems. With the new autofloat controller, operator intervention is reduced to simply applying the mass load indicated by WinPrompt® software. WinPrompt applies all required correction factors, real time, to insure attainment of the highest level of performance available in a gas piston gauge which is required to calibrate today’s RVSM compliant test sets. The Model 2468 is based on the popular Model 2465 Gas Piston Gauge which has a long history of serving national standards laboratories, commercial industry and government organizations as a primary pressure standard for over 40 years. Time-proven materials, hand craftsmanship, and a lineage of intercomparisons to national standards laboratories at the highest levels are coupled with new automated technology to make the Model 2468 Pitot Static Primary Standard the world’s choice for calibrating Air Data Test Systems.
“Fluke 700PTPK Pneumatic Test Kit” has been added to your cart. View cart
Fluke 2468A – Pitot/Static Primary Standard
- Pressure range: 0.4 to 103 inHg
- Optional range: 3.4 to 400 inHg
- Accuracy to ±0.5 feet, 0.003 knots
- Ideal for calibrating RVSM compliant test sets
- Absolute and gauge calibration for Ps, Pt & Qc ranges
- Calibrate in a variety of units
Categories: Fluke Calibration Equipment, Pressure Calibration
Related products
Fluke 719Pro Electric Pressure Calibrator
$8,739.00
Excluding GST 10%
Features
- Electric pump for one handed pressure calibration
- Best in class pressure measurement uncertainty of 0.025%
- Measure and source mA with best in class 0.015% accuracy
- Precision pressure adjust vernier for accurate pressure calibration
- Variable release rate bleed valve for easy pressure adjustment
- Programmable pressure calibrator pump limit: eliminates over-pressurization and allows the user to program target pressures for pumping
- Programmable 3-tiered display for maximum flexibility when displaying pressure, temperature, and electrical parameters of your choice
- Display backlight
- Damping, Min/Max, and % error function
- Source mA with simultaneous pressure measurement to test valves and I/Ps
- Simulate mA signals to troubleshoot 4-20 mA loops
- Test pressure switches with built in switch test function
- Power transmitters during test using 24 V loop supply with simultaneous mA measurement
- Precision temperature measurement with the addition of an accessory RTD probe (available as an option)
- Proven cleanout ports reduce pump failures
- Moisture trap included with the unit helps mitigates risk of moisture damage
Applications
- Pressure Instrument Calibration
- Pressure Instrument Maintenance
- Petro-Chemical
- Oil and Gas
- Pharmaceutical
- Water and wastewater
- Food and Beverage
- Power Generation
Fluke 707 Current Loop Calibrator
$1,929.00
Excluding GST 10%
Key features
- High performance loop calibrator for calibration, repair, and maintenance
- Features large display and simple, quick-click interface for easy one-handed operation.
- Provides simultaneous mA and % readout for quick, easy interpretation of readings.
- Delivers mA accuracy of 0.015%
- Provides 1 µA resolution for mA source, simulate, and measure
Fluke 705 Loop Calibrator
$1,725.00
Excluding GST 10%
Key features
- Powerful loop calibrator that provides a very cost effective, integrated solution for calibration, repair, and maintenance of milliamp loops
- Provides simultaneous mA and % readout for quick, easy interpretation of readings.
- Delivers mA accuracy of 0.02%
- Features push button 25% steps for fast, easy linearity checks
Fluke Calibration 1523 Single Channel Reference Thermometer
$2,820.00
Excluding GST 10%
Features
- Sensor types: PRTs, RTDs, thermistors, and thermocouples
- PRT Accuracy: up to ± 0.011 °C
- Thermocouple Accuracy: up to ± 0.24 °C
- Precision thermistor Accuracy: ± 0.002 °C
- Two models:
- 1523: Single channel standard model with memory for 25 readings
- 1524: Two channels; memory for logging 15,000 measurements
- 0.3 second typical sample interval
- Thermocouple types C, E, J, K, L, M, N, T, U, B, R, S
- Statistics: maximum, minimum, average, standard deviation
Fluke 719-30G Electric Pressure Calibrator, 30 PSI
$8,351.00
Excluding GST 10%
Features
- Fluke 719 30G
- Range: -12 to 36 PSI
- Resolution: 0.001 PSI,
- Accuracy: up to 0.025%
- Fluke 719 100G
- Range: -12 to 120 PSI
- Resolution: 0.01 PSI
- Accuracy: up to 0.025%
- mA:
- Range: 0 to 24 mA
- Accuracy: 0.015 % Rdg + 2 counts
- Max load: 1000Ω; 750 Ω ohm in HART mode
- Pump to:
- 30 PSI in less than 15 seconds (1m of 1/8″ test hose)
- 100 PSI in less than 45 seconds (1m of 1/8″ test hose)
- 5000 pump cycles between rebuilds
- Pump life: 20,000 calibration cycle
- Safety: CSA C22.2 No. 1010.1:1992
- EMC: EN50082-1:1992 and EN55022:1994 Class B
Fluke 712B RTD Temperature Calibrator
$2,846.00
Excluding GST 10%
Features
- Measure and simulate (13) different RTD types and resistance
- Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Configurable 0 % and 100 % source settings
- Linear ramp and 25 % step auto ramp
- Dual inputs and backlit display
- Power down settings
- Max voltage applied between terminal and earth: 30V
- Operating temp: 14 to 122°F (-10 to 50°C)
Fluke 709H Precision mA Loop Calibrator with HART Communications
$2,711.00
Excluding GST 10%
Key features
- mA precision loop calibrator that communicates with and tests HART smart instruments
- Features best-in-class accuracy at 0.01% reading
- Provides intuitive user interface with Quick-Set knob for fast setup
- Includes built in selectable 250 Ω resistor for HART communication
- Features 24 V DC loop power with mA measure mode (-25% to 125%)
Fluke 709 Precision mA Loop Calibrator
$1,877.00
Excluding GST 10%
Key features
- mA precision loop calibrator with best-in-class accuracy at 0.01% reading
- Provides intuitive user interface with quick-set rotary encoder knob for fast setup
- Includes built in selectable 250 Ω resistor for HART communication
- Features 24 V DC loop power with mA Measure Mode (-25% to 125%)
- Requires only simple two wire connection for all measurements