Maintain two triple point of water cells for weeks in a Fluke Calibration 7312 temperature bath or maintain Gallium cells for your fixed point calibrations. This temperature bath can be used as a calibration bath from –5 °C to 110 °C.
View cart “Fluke 773 Milliamp Process Clamp Meter” has been added to your cart.
Fluke 7312 Triple Point of Water Maintenance Bath
- Maintains TPW cells for up to six weeks
- Optional immersion freezer for simple cell freezing
- Independent cutout circuit protects cells from breaking
Categories: Fluke Calibration Equipment, Temperature Calibration
Related products
Fluke 771 Milliamp Process Clamp Meter
Excluding GST 10%
Features
- 0.2% or reading + 5 counts accuracy at -20.99 mA to 20.99 mA
- 1% or reading + 5 counts accuracy at -21.0 mA to -99.9 mA and 21.0 mA to 99.9 mA
- 0.177 in or 4.5mm max diameter of measurable conductor
- -10° to 55°C operating temperature
- IP40 rating
-10%
Close
Fluke 725 Multifunction Process Calibrator
Excluding GST 10%
Features
- Up to 30V and 24mA DC
- 0 to 3200Ω resistance
- Up to 10kHz frequency
- 1V peak-to-peak-minimum senitivity
- Combine with a 750P module for pressure
- Store frequently used test setups for later use
Fluke 726 Precision Multifunction Process Calibrator
Excluding GST 10%
Features
- Up to 20V (source), up to 30V (measure)
- 0 to 24mA source and simulate
- Up to 4000Ω resistance
- Frequency up to 15kHz
- RTD and thermocouple compatible
- Combine with a 750P module for pressure
- Memory storage for up to 8 calibration results
- Perform fast linearity tests with auto step & auto ramp
- 24VDC Loop Supply
- 3-year warranty
Fluke 715 Volt/mA Loop Calibrator
Excluding GST 10%
Key features
- Compact, lightweight mA calibrator for measuring loop current (0-20 mA, 4-20 mA) signals
- Delivers very high accuracy—0.01%—and 1 mA resolution
- Measures voltage output process signals from PLCs and transmitters
- Sources or simulates 24 mA loop current
- Sources voltage to 100 mV or 10V
- Provides typical 18 hour battery life
Fluke 709 Precision mA Loop Calibrator
Excluding GST 10%
Key features
- mA precision loop calibrator with best-in-class accuracy at 0.01% reading
- Provides intuitive user interface with quick-set rotary encoder knob for fast setup
- Includes built in selectable 250 Ω resistor for HART communication
- Features 24 V DC loop power with mA Measure Mode (-25% to 125%)
- Requires only simple two wire connection for all measurements
Fluke 787B Process Meter
Excluding GST 10%
Features
- 400mV up to 1000V voltage range
- Fluke connect
- 20 mA dc current source/measure/simulate
- Simultaneous mA and % of scale readout
- Frequency measurement up to 20 kHz
- Meets IEC 61010 CAT III and 600 V CAT IV standards
- Min/max/average/hold/relative modes
- Diode test and continuity beeper
- -4 to 131°F (-20 to 55°C) operating temp range
Fluke 719-30G Electric Pressure Calibrator, 30 PSI
Excluding GST 10%
Features
- Fluke 719 30G
- Range: -12 to 36 PSI
- Resolution: 0.001 PSI,
- Accuracy: up to 0.025%
- Fluke 719 100G
- Range: -12 to 120 PSI
- Resolution: 0.01 PSI
- Accuracy: up to 0.025%
- mA:
- Range: 0 to 24 mA
- Accuracy: 0.015 % Rdg + 2 counts
- Max load: 1000Ω; 750 Ω ohm in HART mode
- Pump to:
- 30 PSI in less than 15 seconds (1m of 1/8″ test hose)
- 100 PSI in less than 45 seconds (1m of 1/8″ test hose)
- 5000 pump cycles between rebuilds
- Pump life: 20,000 calibration cycle
- Safety: CSA C22.2 No. 1010.1:1992
- EMC: EN50082-1:1992 and EN55022:1994 Class B
Fluke 712B RTD Temperature Calibrator
Excluding GST 10%
Features
- Measure and simulate (13) different RTD types and resistance
- Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Configurable 0 % and 100 % source settings
- Linear ramp and 25 % step auto ramp
- Dual inputs and backlit display
- Power down settings
- Max voltage applied between terminal and earth: 30V
- Operating temp: 14 to 122°F (-10 to 50°C)