- Parameter/Range:-15 to 300 psi (-1 to 20 bar)
- Burst Rating6:4X
- Hi Side Media2:316 SS
- Lo Side Media2:-
- Reference Uncertainty4:± 0.0175%
- Total Uncertainty 1-year (15-35°C):± 0.035%
- Total Uncertainty 1-year1:± 0.045%
- Total Uncertainty 6-month (15-35°C):± 0.03%
- Total Uncertainty 6-month1:± 0.04%
Available on backorder
SKU: 4352616
Categories: Fluke Calibration Equipment, Pressure Calibration
Related products
Fluke 789 / T3000 FC Process Meter / Temp Kit
$2,552.00
Excluding GST 10%
Features
- Compatible with Fluke Connect Mobile App
- 24 V loop power supply
- 1000 V RMS max voltage applied between any jack and earth ground
- Range and resolutions:
- VDC: 400.mV, 4.000 V, 40.00 V, 400.0 V, 1000 V
- VAC (true-rms): 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V
- mA DC: 30.000 mA
- A DC: 1.000 A (0.440 A continuous)
- A AC: 1.000 A (0.440 A continuous)
- HART mode setting with loop power (adds 250 ohm resistor)
- 1200 ohm drive capability on mA source
- Enhanced backlight with two brightness settings
- 0 to 100% mA Span check buttons to toggle between 4 and 20 mA
- Infrared I/O serial port compatible with FlukeView
- -4° to 131°F (-20° to 55°C) operating temperature
Fluke 771 Milliamp Process Clamp Meter
$1,267.00
Excluding GST 10%
Features
- 0.2% or reading + 5 counts accuracy at -20.99 mA to 20.99 mA
- 1% or reading + 5 counts accuracy at -21.0 mA to -99.9 mA and 21.0 mA to 99.9 mA
- 0.177 in or 4.5mm max diameter of measurable conductor
- -10° to 55°C operating temperature
- IP40 rating
Fluke 772 Milliamp Process Clamp Meter
Excluding GST 10%
Features
- mA Measurement Range / Accuracy
- 0 to 20.99 mA / 0.2% + 5 counts (clamp)
- 21.0 to 100.0 mA / 1% + 5 counts (clamp)
- 0 to 24 mA / 0.2% + 2 counts (test jacks)
- mA Source Range / Accuracy
- 0 to 24.00 mA 0.2% / + 2 counts
- mA Simulate Range / Accuracy
- 0 to 24.00 mA 0.2% / + 2 counts
- Simultaneously measure mA in-circuit with 24V loop power
- auto-off, backlight timeout extend battery life
Fluke 725 Multifunction Process Calibrator
$5,319.00
Excluding GST 10%
Features
- Up to 30V and 24mA DC
- 0 to 3200Ω resistance
- Up to 10kHz frequency
- 1V peak-to-peak-minimum senitivity
- Combine with a 750P module for pressure
- Store frequently used test setups for later use
Fluke 787B Process Meter
$2,120.00
Excluding GST 10%
Features
- 400mV up to 1000V voltage range
- Fluke connect
- 20 mA dc current source/measure/simulate
- Simultaneous mA and % of scale readout
- Frequency measurement up to 20 kHz
- Meets IEC 61010 CAT III and 600 V CAT IV standards
- Min/max/average/hold/relative modes
- Diode test and continuity beeper
- -4 to 131°F (-20 to 55°C) operating temp range
Fluke 709 Precision mA Loop Calibrator
$1,877.00
Excluding GST 10%
Key features
- mA precision loop calibrator with best-in-class accuracy at 0.01% reading
- Provides intuitive user interface with quick-set rotary encoder knob for fast setup
- Includes built in selectable 250 Ω resistor for HART communication
- Features 24 V DC loop power with mA Measure Mode (-25% to 125%)
- Requires only simple two wire connection for all measurements
Fluke 724 Temperature Calibrator
$5,248.00
Excluding GST 10%
Features
- Measure Accuracy
- RTD: .2 to .33°C
- Thermocouples: .7 to 1.8°C
- Voltage DC: 0.025% to 0.02%
- Current DC: 0.02%
- Resistance: 0.1 to 1.5%
- Source Accuracy
- Voltage DC: 0.025 to 0.02%
- Resistance: 0.15Ω to 1Ω
Fluke 773 Milliamp Process Clamp Meter
$2,400.00
Excluding GST 10%
Key features
- Loop calibrator that measures 4 to 20 mA signals without breaking the loop
- Features best in class 0.2% accuracy
- Sources 4 to 20 mA signals for testing control system I/O or I/Ps
- Delivers 0.01 mA resolution and sensitivity
- Measures DC voltage to verify 24V power supplies or voltage I/O signals