Fluke Calibration’s constant volume valve is a pneumatically actuated needle valve with a return line connecting the inlet to a coaxial compensator. Needle displacement is matched by an equal and opposite volume displacement on the compensator.
Fluke Constant Volume Valve
The constant volume valve is used in piston gauge crossfloats and other applications in which two high pressures need to be disconnected and reconnected with minimal purturbations on either side.
Categories: Fluke Calibration Equipment, Pressure Calibration
Related products
Fluke Calibration 1523 Single Channel Reference Thermometer
$2,820.00
Excluding GST 10%
Features
- Sensor types: PRTs, RTDs, thermistors, and thermocouples
- PRT Accuracy: up to ± 0.011 °C
- Thermocouple Accuracy: up to ± 0.24 °C
- Precision thermistor Accuracy: ± 0.002 °C
- Two models:
- 1523: Single channel standard model with memory for 25 readings
- 1524: Two channels; memory for logging 15,000 measurements
- 0.3 second typical sample interval
- Thermocouple types C, E, J, K, L, M, N, T, U, B, R, S
- Statistics: maximum, minimum, average, standard deviation
Fluke 712B RTD Temperature Calibrator
$2,846.00
Excluding GST 10%
Features
- Measure and simulate (13) different RTD types and resistance
- Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Configurable 0 % and 100 % source settings
- Linear ramp and 25 % step auto ramp
- Dual inputs and backlit display
- Power down settings
- Max voltage applied between terminal and earth: 30V
- Operating temp: 14 to 122°F (-10 to 50°C)
Fluke 754 Documenting Process Calibrator
$12,443.00
Excluding GST 10%
Features
- Full-featured documenting process calibrator with HART communication for calibrating and troubleshooting HART instrumentation
- Measures volts, mA,TDs, thermocouples, frequency, and ohms to test sensors, transmitters and more
- Sources/simulates volts, mA, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
- Powers transmitters during test using loop supply with simultaneous mA measurement
- Handles fast pulsed rtd transmitters and PLCs, with pulses as short as 1 ms
- Creates and runs automated as-found/as-left procedures to satisfy quality programs or regulations, and records and documents results
- Holds up to a full week of downloaded procedures and calibration results
- Uses many features like autostep, custom units, user-entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay and more
- Provides easy-to-use multi-lingual interface
- Features a bright white dual display for reading both sourced and measured parameters simultaneously
- Offers compatibility with many asset management software packages
- Multifunctional
- Powerful, yet easy to use
- Records and documents results
- Truly hand-held
- Rugged and reliable
- Bright white display
- Soft keys
- Three operating modes
- Multi-lingual interface
- Built-in algebraic calculator
- Programmable measurement delay
Fluke 709H Precision mA Loop Calibrator with HART Communications
$2,711.00
Excluding GST 10%
Key features
- mA precision loop calibrator that communicates with and tests HART smart instruments
- Features best-in-class accuracy at 0.01% reading
- Provides intuitive user interface with Quick-Set knob for fast setup
- Includes built in selectable 250 Ω resistor for HART communication
- Features 24 V DC loop power with mA measure mode (-25% to 125%)
Fluke 725 Multifunction Process Calibrator
$5,319.00
Excluding GST 10%
Features
- Up to 30V and 24mA DC
- 0 to 3200Ω resistance
- Up to 10kHz frequency
- 1V peak-to-peak-minimum senitivity
- Combine with a 750P module for pressure
- Store frequently used test setups for later use
Fluke 714B Temperature Calibrator
$2,984.00
Excluding GST 10%
Features
- Measure and simulate 17 different thermocouple types
- Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Configurable 0 % and 100 % source settings
- Linear ramp and 25 % step auto ramp
- Dual inputs and backlit display
- Power down settings
- Max voltage applied between terminal and earth: 30V
- Operating temp: 14 to 122°F (-10 to 50°C)
- Hanging tool designed in and included with every unit
Fluke 772 Milliamp Process Clamp Meter
Excluding GST 10%
Features
- mA Measurement Range / Accuracy
- 0 to 20.99 mA / 0.2% + 5 counts (clamp)
- 21.0 to 100.0 mA / 1% + 5 counts (clamp)
- 0 to 24 mA / 0.2% + 2 counts (test jacks)
- mA Source Range / Accuracy
- 0 to 24.00 mA 0.2% / + 2 counts
- mA Simulate Range / Accuracy
- 0 to 24.00 mA 0.2% / + 2 counts
- Simultaneously measure mA in-circuit with 24V loop power
- auto-off, backlight timeout extend battery life
Fluke 773 Milliamp Process Clamp Meter
$2,539.00
Excluding GST 10%
Key features
- Loop calibrator that measures 4 to 20 mA signals without breaking the loop
- Features best in class 0.2% accuracy
- Sources 4 to 20 mA signals for testing control system I/O or I/Ps
- Delivers 0.01 mA resolution and sensitivity
- Measures DC voltage to verify 24V power supplies or voltage I/O signals