Fluke Calibration provides the complete solution for pressure calibration using a deadweight tester, including accessories for test media separation, dirt / moisture traps, dial gauge pointer removers, angle adapters, and two gauge test stands.
“Fluke 712B RTD Temperature Calibrator” has been added to your cart. View cart
Fluke P5500 Adapters, Separators and Dirt/Moisture Traps
Categories: Fluke Calibration Equipment, Pressure Calibration
Related products
Fluke 787B Process Meter
$2,120.00
Excluding GST 10%
Features
- 400mV up to 1000V voltage range
- Fluke connect
- 20 mA dc current source/measure/simulate
- Simultaneous mA and % of scale readout
- Frequency measurement up to 20 kHz
- Meets IEC 61010 CAT III and 600 V CAT IV standards
- Min/max/average/hold/relative modes
- Diode test and continuity beeper
- -4 to 131°F (-20 to 55°C) operating temp range
Fluke Calibration 1524 Dual Channel Reference Thermometer
$3,370.00
Excluding GST 10%
Features
- Sensor types: PRTs, RTDs, thermistors, and thermocouples
- PRT Accuracy: up to ± 0.011 °C
- Thermocouple Accuracy: up to ± 0.24 °C
- Precision thermistor Accuracy: ± 0.002 °C
- Two models:
- 1523: Single channel standard model with memory for 25 readings
- 1524: Two channels; memory for logging 15,000 measurements
- 0.3 second typical sample interval
- Thermocouple types C, E, J, K, L, M, N, T, U, B, R, S
- Statistics: maximum, minimum, average, standard deviation
Fluke 714B Temperature Calibrator
$2,984.00
Excluding GST 10%
Features
- Measure and simulate 17 different thermocouple types
- Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Configurable 0 % and 100 % source settings
- Linear ramp and 25 % step auto ramp
- Dual inputs and backlit display
- Power down settings
- Max voltage applied between terminal and earth: 30V
- Operating temp: 14 to 122°F (-10 to 50°C)
- Hanging tool designed in and included with every unit
Fluke 700PTPK Pneumatic Test Kit
$1,623.00
Excluding GST 10%
The Fluke-700PTPK Pneumatic Test Kit features include:
- Combine with any Fluke-700G Series Gauge, 1,000 psi or less, to make a complete pressure testing kit
- Generate pressure up to 600 psi, 40 bar with the 700PTP-1 test pump.
- Connect the 700G Series gauge directly to the included PTP-1 hand pump
- Includes hoses and adapters for connecting to the pressure device to be tested
- Hard case protects pump and gauge and allows gauge to remain connected to the pump
Fluke 772 Milliamp Process Clamp Meter
Excluding GST 10%
Features
- mA Measurement Range / Accuracy
- 0 to 20.99 mA / 0.2% + 5 counts (clamp)
- 21.0 to 100.0 mA / 1% + 5 counts (clamp)
- 0 to 24 mA / 0.2% + 2 counts (test jacks)
- mA Source Range / Accuracy
- 0 to 24.00 mA 0.2% / + 2 counts
- mA Simulate Range / Accuracy
- 0 to 24.00 mA 0.2% / + 2 counts
- Simultaneously measure mA in-circuit with 24V loop power
- auto-off, backlight timeout extend battery life
Fluke 705 Loop Calibrator
$1,725.00
Excluding GST 10%
Key features
- Powerful loop calibrator that provides a very cost effective, integrated solution for calibration, repair, and maintenance of milliamp loops
- Provides simultaneous mA and % readout for quick, easy interpretation of readings.
- Delivers mA accuracy of 0.02%
- Features push button 25% steps for fast, easy linearity checks
Fluke 715 Volt/mA Loop Calibrator
$2,846.00
Excluding GST 10%
Key features
- Compact, lightweight mA calibrator for measuring loop current (0-20 mA, 4-20 mA) signals
- Delivers very high accuracy—0.01%—and 1 mA resolution
- Measures voltage output process signals from PLCs and transmitters
- Sources or simulates 24 mA loop current
- Sources voltage to 100 mV or 10V
- Provides typical 18 hour battery life
Fluke 712B RTD Temperature Calibrator
$2,846.00
Excluding GST 10%
Features
- Measure and simulate (13) different RTD types and resistance
- Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Configurable 0 % and 100 % source settings
- Linear ramp and 25 % step auto ramp
- Dual inputs and backlit display
- Power down settings
- Max voltage applied between terminal and earth: 30V
- Operating temp: 14 to 122°F (-10 to 50°C)