The SPLT is a free standing accessory designed to protect the PPC from liquid contamination returning from the system or device under test.
“Fluke 709H Precision mA Loop Calibrator with HART Communications” has been added to your cart. View cart
Fluke SPLT Self Purging Liquid Trap
The SPLT is made up of a stainless steel body with an internal X-Type coalescing filter and a bottom drain port fitting with an electrically actuated purge valve. The filter and valve assembly is installed in a mounting stand.
The SPLT is intended to collect and exhaust liquid contaminants that may be present in the device or system under test so that they do NOT return to the PPC.
Categories: Fluke Calibration Equipment, Pressure Calibration
Related products
Fluke 719-30G Electric Pressure Calibrator, 30 PSI
$8,351.00
Excluding GST 10%
Features
- Fluke 719 30G
- Range: -12 to 36 PSI
- Resolution: 0.001 PSI,
- Accuracy: up to 0.025%
- Fluke 719 100G
- Range: -12 to 120 PSI
- Resolution: 0.01 PSI
- Accuracy: up to 0.025%
- mA:
- Range: 0 to 24 mA
- Accuracy: 0.015 % Rdg + 2 counts
- Max load: 1000Ω; 750 Ω ohm in HART mode
- Pump to:
- 30 PSI in less than 15 seconds (1m of 1/8″ test hose)
- 100 PSI in less than 45 seconds (1m of 1/8″ test hose)
- 5000 pump cycles between rebuilds
- Pump life: 20,000 calibration cycle
- Safety: CSA C22.2 No. 1010.1:1992
- EMC: EN50082-1:1992 and EN55022:1994 Class B
Fluke 725 Multifunction Process Calibrator
$5,319.00
Excluding GST 10%
Features
- Up to 30V and 24mA DC
- 0 to 3200Ω resistance
- Up to 10kHz frequency
- 1V peak-to-peak-minimum senitivity
- Combine with a 750P module for pressure
- Store frequently used test setups for later use
Fluke 724 Temperature Calibrator
$5,248.00
Excluding GST 10%
Features
- Measure Accuracy
- RTD: .2 to .33°C
- Thermocouples: .7 to 1.8°C
- Voltage DC: 0.025% to 0.02%
- Current DC: 0.02%
- Resistance: 0.1 to 1.5%
- Source Accuracy
- Voltage DC: 0.025 to 0.02%
- Resistance: 0.15Ω to 1Ω
Fluke Calibration 1523 Single Channel Reference Thermometer
$2,820.00
Excluding GST 10%
Features
- Sensor types: PRTs, RTDs, thermistors, and thermocouples
- PRT Accuracy: up to ± 0.011 °C
- Thermocouple Accuracy: up to ± 0.24 °C
- Precision thermistor Accuracy: ± 0.002 °C
- Two models:
- 1523: Single channel standard model with memory for 25 readings
- 1524: Two channels; memory for logging 15,000 measurements
- 0.3 second typical sample interval
- Thermocouple types C, E, J, K, L, M, N, T, U, B, R, S
- Statistics: maximum, minimum, average, standard deviation
Fluke 771 Milliamp Process Clamp Meter
$1,267.00
Excluding GST 10%
Features
- 0.2% or reading + 5 counts accuracy at -20.99 mA to 20.99 mA
- 1% or reading + 5 counts accuracy at -21.0 mA to -99.9 mA and 21.0 mA to 99.9 mA
- 0.177 in or 4.5mm max diameter of measurable conductor
- -10° to 55°C operating temperature
- IP40 rating
Fluke 707 Current Loop Calibrator
$1,929.00
Excluding GST 10%
Key features
- High performance loop calibrator for calibration, repair, and maintenance
- Features large display and simple, quick-click interface for easy one-handed operation.
- Provides simultaneous mA and % readout for quick, easy interpretation of readings.
- Delivers mA accuracy of 0.015%
- Provides 1 µA resolution for mA source, simulate, and measure
Fluke 719Pro Electric Pressure Calibrator
$8,739.00
Excluding GST 10%
Features
- Electric pump for one handed pressure calibration
- Best in class pressure measurement uncertainty of 0.025%
- Measure and source mA with best in class 0.015% accuracy
- Precision pressure adjust vernier for accurate pressure calibration
- Variable release rate bleed valve for easy pressure adjustment
- Programmable pressure calibrator pump limit: eliminates over-pressurization and allows the user to program target pressures for pumping
- Programmable 3-tiered display for maximum flexibility when displaying pressure, temperature, and electrical parameters of your choice
- Display backlight
- Damping, Min/Max, and % error function
- Source mA with simultaneous pressure measurement to test valves and I/Ps
- Simulate mA signals to troubleshoot 4-20 mA loops
- Test pressure switches with built in switch test function
- Power transmitters during test using 24 V loop supply with simultaneous mA measurement
- Precision temperature measurement with the addition of an accessory RTD probe (available as an option)
- Proven cleanout ports reduce pump failures
- Moisture trap included with the unit helps mitigates risk of moisture damage
Applications
- Pressure Instrument Calibration
- Pressure Instrument Maintenance
- Petro-Chemical
- Oil and Gas
- Pharmaceutical
- Water and wastewater
- Food and Beverage
- Power Generation
Fluke 712B RTD Temperature Calibrator
$2,846.00
Excluding GST 10%
Features
- Measure and simulate (13) different RTD types and resistance
- Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Configurable 0 % and 100 % source settings
- Linear ramp and 25 % step auto ramp
- Dual inputs and backlit display
- Power down settings
- Max voltage applied between terminal and earth: 30V
- Operating temp: 14 to 122°F (-10 to 50°C)