The SPLT is a free standing accessory designed to protect the PPC from liquid contamination returning from the system or device under test.
“Fluke Calibration 1523 Single Channel Reference Thermometer” has been added to your cart. View cart
Fluke SPLT Self Purging Liquid Trap
The SPLT is made up of a stainless steel body with an internal X-Type coalescing filter and a bottom drain port fitting with an electrically actuated purge valve. The filter and valve assembly is installed in a mounting stand.
The SPLT is intended to collect and exhaust liquid contaminants that may be present in the device or system under test so that they do NOT return to the PPC.
Categories: Fluke Calibration Equipment, Pressure Calibration
Related products
Fluke 726 Precision Multifunction Process Calibrator
$7,150.00
Excluding GST 10%
Features
- Up to 20V (source), up to 30V (measure)
- 0 to 24mA source and simulate
- Up to 4000Ω resistance
- Frequency up to 15kHz
- RTD and thermocouple compatible
- Combine with a 750P module for pressure
- Memory storage for up to 8 calibration results
- Perform fast linearity tests with auto step & auto ramp
- 24VDC Loop Supply
- 3-year warranty
Fluke 725 Multifunction Process Calibrator
$5,319.00
Excluding GST 10%
Features
- Up to 30V and 24mA DC
- 0 to 3200Ω resistance
- Up to 10kHz frequency
- 1V peak-to-peak-minimum senitivity
- Combine with a 750P module for pressure
- Store frequently used test setups for later use
Fluke 724 Temperature Calibrator
$5,248.00
Excluding GST 10%
Features
- Measure Accuracy
- RTD: .2 to .33°C
- Thermocouples: .7 to 1.8°C
- Voltage DC: 0.025% to 0.02%
- Current DC: 0.02%
- Resistance: 0.1 to 1.5%
- Source Accuracy
- Voltage DC: 0.025 to 0.02%
- Resistance: 0.15Ω to 1Ω
Fluke 700HTPK2 Hydraulic Test Pressure Kit
$3,182.00
Excluding GST 10%
Features
- Generate pressure up to 10,000 psi, 690 bar with the included 700HTP-2 test pump
- Includes 700TTH 10K premium/no tools required transmitter test hose kit and adapters
- Hard case protects pump and gauge and allows gauge to remain connected to the pump
- Can be combined with any Fluke 700G Series Gauge, 1,000 psi range or greater, to make a complete pressure testing kit
Fluke 773 Milliamp Process Clamp Meter
$2,400.00
Excluding GST 10%
Key features
- Loop calibrator that measures 4 to 20 mA signals without breaking the loop
- Features best in class 0.2% accuracy
- Sources 4 to 20 mA signals for testing control system I/O or I/Ps
- Delivers 0.01 mA resolution and sensitivity
- Measures DC voltage to verify 24V power supplies or voltage I/O signals
Fluke 789 Advanced ProcessMeter
$2,099.00
Excluding GST 10%
Key features
- Ultimate troubleshooting tool for electricians and instrumentation professionals
- Combines the functionality of a loop calibrator with the power of a precision 1000 V, 440 mA True-RMS digital multimeter
- Provided with optional IR3000FC module for wireless data logging capabilities via Fluke Connect® mobile App
- Includes 24 V loop power supply
- Features a very large dual display with enhanced two-level backlight brightness settings
Fluke 719-30G Electric Pressure Calibrator, 30 PSI
$8,351.00
Excluding GST 10%
Features
- Fluke 719 30G
- Range: -12 to 36 PSI
- Resolution: 0.001 PSI,
- Accuracy: up to 0.025%
- Fluke 719 100G
- Range: -12 to 120 PSI
- Resolution: 0.01 PSI
- Accuracy: up to 0.025%
- mA:
- Range: 0 to 24 mA
- Accuracy: 0.015 % Rdg + 2 counts
- Max load: 1000Ω; 750 Ω ohm in HART mode
- Pump to:
- 30 PSI in less than 15 seconds (1m of 1/8″ test hose)
- 100 PSI in less than 45 seconds (1m of 1/8″ test hose)
- 5000 pump cycles between rebuilds
- Pump life: 20,000 calibration cycle
- Safety: CSA C22.2 No. 1010.1:1992
- EMC: EN50082-1:1992 and EN55022:1994 Class B
Fluke Calibration 1524 Dual Channel Reference Thermometer
$3,370.00
Excluding GST 10%
Features
- Sensor types: PRTs, RTDs, thermistors, and thermocouples
- PRT Accuracy: up to ± 0.011 °C
- Thermocouple Accuracy: up to ± 0.24 °C
- Precision thermistor Accuracy: ± 0.002 °C
- Two models:
- 1523: Single channel standard model with memory for 25 readings
- 1524: Two channels; memory for logging 15,000 measurements
- 0.3 second typical sample interval
- Thermocouple types C, E, J, K, L, M, N, T, U, B, R, S
- Statistics: maximum, minimum, average, standard deviation