The Fluke TL81A Deluxe Electronic Test lead kit is ideal for testing electronic equipment. It offers test versatility with modular test probes, alligator clips, test clips and other accessories included and can attach directly to the SureGrip™ test leads. The kit consists of a quad fold nylon pouch containing 11 items.
Features
- Silicone-insulated leads have superior flexibility in cold temperatures and resistance to high temperatures
- Insulated alligator clip rated up to 5A
- Insulated probe tip extender rated up to 3A
- Modular test probe with banana connector in the handle, rated up to 10A
- Modular hook-style clip test lead with banana connector, rated up to 5A
- Modular pinch-style clip test lead with banana connector, rated up to 5A
- Modular alligator clip with banana connector, rated up to 5A
- Slide-on IC probe tip adapter (rated up to 3A) and test lead couplers
- Bare spade lug with banana connector, rated up to 10A
- One year warranty
Applications
- Test and Measurement
- Oil and Gas
- R&D
- Electronics Design
- Electronics Service
- Repair and Maintenance
- Electrical
- Industrial
Available on backorder
Related products
Fluke 435-II Three Phase Power Quality Analyzers
Excluding GST 10%
Key features
The Fluke 435-II products are designed for users who need to get to the solution of the power quality problem as quickly as possible so that they can minimize expensive downtime. The measurement process and display of data is optimized to get to the most important information as quickly as possible. Multiple parameters are measured simultaneously and displayed in formats that quickly describe overall power quality health while giving you the detailed information you need to make better maintenance decisions. Data can be quickly accessed as simple digital values, trend graphs that give you fast insight into changes over time, waveforms, phasor diagrams or analyzed and organized into tabular format such as the event data where the magnitude, duration and time stamping enable rapid correlation to the problems you are experiencing in your facility.
Energy loss Calculator—Calculate money lost to energy waste in terms of real dollars.
It’s a simple fact, poor power quality can have a big impact on the bottom line. The Fluke 435-II enables you to identify issues and measure energy loss giving you specific insight into the amount of loss in dollars associated things like effective power and with poor power quality characteristics such as reactive power, unbalance, distortion, or neutral current. The 435-II even offers users the flexibility to input cable length and cable diameter so you can calculate loss due to conductor sizing (Or use AUTO mode if you don’t know your cable specification) and enter up to four unique time-dependent daily rates (kWh) for more accurate calculations. Armed with this critical data users can easily justify the investment necessary to take countermeasures.
Fluke 124B ScopeMeter Oscilloscope
Excluding GST 10%
Features
- Dual-input digital oscilloscope and multimeter
- 20 or 40MHz bandwidth
- 5mV to 200V/div sensitivity
- VDC and true-rms VAC ranges from 500mV to 750V
- 5000 count full scale reading
- Up to 2200V peak (max, min, & peak-to-peak modes)
- 5% FS accuracy (min or max), 10% (peak-to-peak)
- 500 counts full scale reading
- Up to 70MHz frequency for 124B & 125B
- Up to 50MHz for 123B
- Measure resistance, continuity, diode, & capacitance
- CE & CSA approved, CAT IV 600V safety rated
Fluke 820-2 LED Stroboscope
Excluding GST 10%
Features
- 30 to 300,000 FPM (flashes per minute)
- 0.5 to 5000 Hz frequency range
- FPM or Hz frequency setting
- 0.02% accuracy
- Digital pulse width modulation
- Multi-line LCD display
- Operating temp: 32 to 113°F (0 to 45°C)
Fluke 125B ScopeMeter Oscilloscope
Excluding GST 10%
Features
- Dual-input digital oscilloscope and multimeter
- 20 or 40MHz bandwidth
- 5mV to 200V/div sensitivity
- VDC and true-rms VAC ranges from 500mV to 750V
- 5000 count full scale reading
- Up to 2200V peak (max, min, & peak-to-peak modes)
- 5% FS accuracy (min or max), 10% (peak-to-peak)
- 500 counts full scale reading
- Up to 70MHz frequency for 124B & 125B
- Up to 50MHz for 123B
- Measure resistance, continuity, diode, & capacitance
- CE & CSA approved, CAT IV 600V safety rated
Fluke 810 Vibration Tester
Excluding GST 10%
Features
- Plain-text diagnosis of standard faults:
- Unbalance
- Looseness
- Misalignment
- Bearing failures
- Fault severity (slight, moderate, serious, extreme)
- 200 rpm to 12000 rpm machine rotational speed range
- 5 Hz to 20 kHz Usable frequency bandwidth
- 2.56 kHz to 51.2 kHz sampling rate
- Lithium-ion, 14.8 V, 2.55 Ah battery
- 1/4 VGA, 320 × 240 color display
- Auto ranging
Fluke BT-520 Battery Analyzer
Excluding GST 10%
Key features
Fluke BT510 key features:
- Battery Voltage – During the internal resistance test, Fluke Battery Analyzers also measure the voltage of the battery under test
- Discharge Volts – The Discharge mode collects the voltage of each battery multiple times at a user defined interval during a discharge or load test. Users can calculate the time a battery takes to drop to the cut-off voltage and use this time to determine the capacity loss of the battery
- Ripple Voltage Test – Measures unwanted residual ac component of the rectified voltage in dc charging and inverter circuits. Allows users to test ac components in dc charging circuits and find one of the root causes of battery deterioration
- Meter and Sequence Modes – The Meter mode is used for a quick test or troubleshooting. In this mode you can save and read the readings in a measurement or time sequence. The Sequence mode is for maintenance tasks with multiple power systems and battery strings. Before a task starts, users can configure a profile for the task for data management and report generation
- Threshold and Warning – Users can configure a maximum of 10 sets of thresholds and receive a Pass/ Warning/ Fail indication after each measurement
- Intercell Strap Resistance Test and Data Management – Measures the resistance of the intercell connection between batteries in a string. Once the measurements are completed Fluke Battery Management Software version 1.0.69 can now report the strap resistance for a battery string or historical data over time.
- AutoHold – When AutoHold is turned on, a reading is captured when it remains stable for 1 second. The reading is then released when a new measurement starts
- AutoSave – When AutoSave is turned on, measured values are saved to internal memory automatically after an AutoHold reading is captured
Fluke 6200-2 Portable Appliance Testers
Excluding GST 10%
Key features
Fluke Simplifies Portable Appliance Testing
- Dedicated key for each test for ‘one-touch’ testing
- Pre-set pass/fail levels to save time
- Large backlit display for easy reading
- Single mains socket for appliance connection
- Separate IEC socket for easy mains/extension lead testing
- Detachable test leads for quick field replacement
- Integral carrying handle
- USB port for data transfer
Fluke 805 FC Vibration Meter
Excluding GST 10%
Features
- Low frequency range:10 Hz to 1,000 Hz
- High frequency range: 4,000 Hz to 20,000 Hz
- Crest Factor+ technology
- Four-level severity scale
- Exportable data via USB
- Trending in Microsoft® Excel using built-in templates
- Saves up to 3,500 measurements
- Compatible with Fluke Connect Mobile App