The 80PR 60 probe expands the utility of your RTD non-contact infrared thermometer by allowing you to take contact temperature readings. You can make contact and non-contact readings at the same time because your RTD infrared thermometer displays the results of both. Just plug the temperature probe into the RTD jack, position the probe tip at or below the surface of your target, and start reading temperatures. (Refer to thermometer user manual for details.)
Excluding GST 10%
Excluding GST 10%
Fluke 80PR-60 RTD Temperature Probe
$206.00Excluding GST 10%
- Probe type: RTD (resistance temperature detector)
- Probe element: Platinum 1 KW
- Temperature range: -40 to 260 °C (-40 to 500 °F)
- Accuracy: ± 1 °C (± 2 °F)
- Jack: 3.5 mm phono type
- Probe diameter: 4.8 mm (.187 in)
- Probe length: 90 mm (3.5 in)
- Cable length (extended): 1000 mm (40 in)
- For use with the Fluke 66 and Fluke 68
Available on backorder
Related products
Fluke 125B ScopeMeter Oscilloscope
Excluding GST 10%
Features
- Dual-input digital oscilloscope and multimeter
- 20 or 40MHz bandwidth
- 5mV to 200V/div sensitivity
- VDC and true-rms VAC ranges from 500mV to 750V
- 5000 count full scale reading
- Up to 2200V peak (max, min, & peak-to-peak modes)
- 5% FS accuracy (min or max), 10% (peak-to-peak)
- 500 counts full scale reading
- Up to 70MHz frequency for 124B & 125B
- Up to 50MHz for 123B
- Measure resistance, continuity, diode, & capacitance
- CE & CSA approved, CAT IV 600V safety rated
Fluke 123B Industrial ScopeMeter® Hand-Held Oscilloscope, 20 MHz
Excluding GST 10%
Features
- Dual-input digital oscilloscope and multimeter
- 20 MHz oscilloscope bandwidth
- Two 5000-count True RMS digital multimeters
- Connect-and-View™ trigger simplicity for hands-off operation
- IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal
- Dual-input waveform and meter reading recorder for trending data over extended periods
- Recorder Event Detect captures elusive intermittent signals on repetitive waveforms up to 4 kHz
- Shielded test leads for oscilloscope, resistance and continuity measurements
- Resistance, continuity, diode and capacitance meter measurements
- Power measurements (W, VA, VAR, PF, DPF, Hz)
- Voltage, current and power harmonics
- Check Industrial networks with BusHealth physical layer tests against defined reference levels
- Save or recall data and instrument setups
- Store instrument setups defined by a test sequence for routine maintenance or most often used test procedures
- External optically isolated USB interface to transfer, archive and analyze scope or meter data
- Optional WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app
- FlukeView® ScopeMeter® Software for Windows®
- Rugged design to withstand 3g Vibration, 30g shock, and rated IP51 according to EN/IEC60529
- Highest safety rating in the industry: safety rated for CAT IV 600 V
Fluke 435-II Three Phase Power Quality Analyzers
Excluding GST 10%
Key features
The Fluke 435-II products are designed for users who need to get to the solution of the power quality problem as quickly as possible so that they can minimize expensive downtime. The measurement process and display of data is optimized to get to the most important information as quickly as possible. Multiple parameters are measured simultaneously and displayed in formats that quickly describe overall power quality health while giving you the detailed information you need to make better maintenance decisions. Data can be quickly accessed as simple digital values, trend graphs that give you fast insight into changes over time, waveforms, phasor diagrams or analyzed and organized into tabular format such as the event data where the magnitude, duration and time stamping enable rapid correlation to the problems you are experiencing in your facility.
Energy loss Calculator—Calculate money lost to energy waste in terms of real dollars.
It’s a simple fact, poor power quality can have a big impact on the bottom line. The Fluke 435-II enables you to identify issues and measure energy loss giving you specific insight into the amount of loss in dollars associated things like effective power and with poor power quality characteristics such as reactive power, unbalance, distortion, or neutral current. The 435-II even offers users the flexibility to input cable length and cable diameter so you can calculate loss due to conductor sizing (Or use AUTO mode if you don’t know your cable specification) and enter up to four unique time-dependent daily rates (kWh) for more accurate calculations. Armed with this critical data users can easily justify the investment necessary to take countermeasures.
Fluke 6500-2 Portable Appliance Tester
Excluding GST 10%
Key features
Fluke Simplifies Portable Appliance Testing
- Dedicated key for each test for ‘one-touch’ testing
- Pre-set pass/fail levels to save time
- Large backlit display for easy reading
- Single mains socket for appliance connection
- Separate IEC socket for easy mains/extension lead testing
- Detachable test leads for quick field replacement
- Integral carrying handle
- USB port for data transfer
Fluke 190 Series II 100MHz 2 Channel ScopeMeter Oscilloscope
Excluding GST 10%
- IEC 61010 1000V CAT III / 600V CAT IV Safety rating
- 2 fully isolated floating input channels with up to 1.25 GS/s real time sampling rate
- 8ns Glitch detect
- 10,000 sample deep memory per channel for displaying high resolution waveform details
- 2 input channels provide: 2 meter measurements, 2 TrendPlot traces, 2 ScopeRecord traces, capturing or logging 2 inputs over time
- Live Zoom with full resolution
Fluke 805 FC Vibration Meter
Excluding GST 10%
Features
- Low frequency range:10 Hz to 1,000 Hz
- High frequency range: 4,000 Hz to 20,000 Hz
- Crest Factor+ technology
- Four-level severity scale
- Exportable data via USB
- Trending in Microsoft® Excel using built-in templates
- Saves up to 3,500 measurements
- Compatible with Fluke Connect Mobile App
Fluke DS703 FC Diagnostic Videoscope
Excluding GST 10%
Key features
- High definition probe with dual-view camera
- Processing speeds that render a smooth, clear, consistent image
- 7” LCD screen for easy viewing
- Macro to micro zoom function
- Adjustable lighting to capture the best image
- Up is Up® technology for an appropriate orientation, regardless of the probe location
- Fluke Connect® allows you to save and share images directly from the diagnostic scope
Fluke 190 Series II 60MHz ScopeMeter Oscilloscope
Excluding GST 10%
Features
- Four independent isolated input channels
- 60, 100, 200 and 500 MHz bandwidths
- Sample rate: Up to 2.5 GS/s
- Sample rate resolution: Up to 400 ps
- Deep memory: 10,000 point per trace waveform capture
- CAT III 1000 V / CAT IV 600 V safety rating
- Seven hour, high performance Li-ion batteries
- Battery door for convenient battery access
- Isolated USB ports for memory devices and PC connectivity