Fluke 718EX-300 Intrinsically Safe Pressure Calibrator
Features
- Pressure Source and Milliamp Measurement to calibrate and maintain almost any pressure device
- Integrated pump is easily cleaned when accidently exposed to fluids that reduces cost of ownership and repairs and enables servicing the pump in the field
- Error % calculation for quicker pass/fail decision making in the field
- Best in class mA accuracy of 0.015 % for better measurement confidence and workload coverage
- Min/Max/Hold to capture changing measurements
- Switch test feature for quicker and more accurate pressure switch testing
- New 1 and 300 PSI pressure ranges mean fewer extra tools required
- 1, 30, 100 & 300 PSI ranges now available
Applications
- Pressure instrument calibration
- Pressure instrument Maintenance
- Petro-Chemical
- Oil and Gas
- Pharmaceutical
- Water and wastewater
- Food and Beverage
- Power Generation
Fluke 718Ex-30G Intrinsically Safe Pressure Calibrator
Features
- True RMS current and voltage measurements gives you accurate readings of non-sinusoidal waveforms
- Multimeter functions include AC/DC voltage, resistance, capacitance, frequency, diode and continuity
- Peak hold captures inrush currents and transients
- Data hold and Max/Min functions
- 4000-count backlit display
- Autoranging with manual range button
- Auto power off
- 1.7″ (43mm) jaw opening for conductors up to 750MCM or two 500MCM
- Complete with Type K thermocouple probe, test leads, 9V battery and belt holster
Fluke 719-100G Pressure Calibrator, 100 PSI
Features
- Measure and source mA with best in class 0.015% accuracy
- Precision pressure adjust vernier for accurate pressure calibration
- Variable release rate bleed valve for easy pressure adjustment
- Ideal performance for high accuracy transmitter calibration
- 30 PSI and 100 PSI pressure ranges
- Programmable pressure calibrator pump limit
- eliminates over-pressurization
- allows the user to program target pressures for pumping
- Extended pressure measurement range with any of 29 700Pxx Pressure Modules
- Source mA with simultaneous pressure measurement to test valves and I/Ps
- Simulate mA signals to troubleshoot 4-20 mA loops
- Test pressure switches with built in switch test function
- Power transmitters during test using 24 V loop supply with simultaneous mA measurement
- Pressure Calibrator includes proven cleanout ports reduce pump failures
Applications
- Petro-Chemical
- Oil and Gas
- Food and Beverage
- Pharmaceutical
- Test and Measurement
- Instrumentation
Fluke 719-30G Electric Pressure Calibrator, 30 PSI
Features
- Fluke 719 30G
- Range: -12 to 36 PSI
- Resolution: 0.001 PSI,
- Accuracy: up to 0.025%
- Fluke 719 100G
- Range: -12 to 120 PSI
- Resolution: 0.01 PSI
- Accuracy: up to 0.025%
- mA:
- Range: 0 to 24 mA
- Accuracy: 0.015 % Rdg + 2 counts
- Max load: 1000Ω; 750 Ω ohm in HART mode
- Pump to:
- 30 PSI in less than 15 seconds (1m of 1/8″ test hose)
- 100 PSI in less than 45 seconds (1m of 1/8″ test hose)
- 5000 pump cycles between rebuilds
- Pump life: 20,000 calibration cycle
- Safety: CSA C22.2 No. 1010.1:1992
- EMC: EN50082-1:1992 and EN55022:1994 Class B
Fluke 719PRO-150G Electric Pressure Calibrator, 150 PSI/10 Bar
Features
- Electric pump for one handed pressure calibration
- Best in class pressure measurement uncertainty of 0.025%
- Measure and source mA with best in class 0.015% accuracy
- Precision pressure adjust vernier for accurate pressure calibration
- Variable release rate bleed valve for easy pressure adjustment
- Programmable pressure calibrator pump limit: eliminates over-pressurization and allows the user to program target pressures for pumping
- Programmable 3-tiered display for maximum flexibility when displaying pressure, temperature, and electrical parameters of your choice
- Display backlight
- Damping, Min/Max, and % error function
- Source mA with simultaneous pressure measurement to test valves and I/Ps
- Simulate mA signals to troubleshoot 4-20 mA loops
- Test pressure switches with built in switch test function
- Power transmitters during test using 24 V loop supply with simultaneous mA measurement
- Precision temperature measurement with the addition of an accessory RTD probe (available as an option)
- Proven cleanout ports reduce pump failures
- Moisture trap included with the unit helps mitigates risk of moisture damage
Applications
- Petro-Chemical
- Oil and Gas
- Pharmaceutical
- Water and wastewater
- Food and Beverage
- Power Generation
Fluke 71X Hose Kit
Fluke 71X Hose Kit Accessory Overview The Fluke 71X Hose Kit is compatible with the 717 and 718 calibrators 100 PSI
Fluke 71XTrap Liquid and Dirt Trap
Liquid and dirt trap for use with Fluke 718 and 719Pro.
Fluke 720RTD Probe
RTD probe for use with Fluke 721 and 719Pro.
Fluke 720URTDA Universal RTD adapter
For use with the Fluke 719 and 721.
Fluke 721-1601 Dual Sensor Pressure Calibrator
Features
- Two isolated, stainless steel, pressure sensors with 0.025% f.s. accuracy
- Can be configured by selecting either a 16 psig (1.1 bar) or 36 psig (2.48 bar) low pressure sensor and then adding your choice of 7 high pressure ranges
- External pressure module connection supports all pressure modules (29 ranges) for even more measurement capability
- Temperature-compensation ensures accuracy in field applications
- Pt100 RTD input for temperature measurement, accurate to 0.1°C (0.2°F) (Requires optional RTD probe sold separately)
- Measure 4-20 mA signals
- Internal 24 V Loop Power Supply can power a transmitter under test
- Measure up to 30 V DC
- Large graphic style LCD with backlight can be configured to display up to 3 inputs simultaneously (i.e. pressure 1, pressure 2, and RTD or any combination of inputs)
- Pressure displayed in the user’s choice of 19 engineering units
- Switch test on both pressure inputs, or external pressure module
- Operating mode layers support simple measurements to complex applications
- Up to five frequently used setups can be stored; last setup automatically recalled on power-up
- % error and damping functions
Fluke 721-1603 Dual Sensor Pressure Calibrator
Features
- Two isolated, stainless steel, pressure sensors with 0.025% f.s. accuracy
- Can be configured by selecting either a 16 psig (1.1 bar) or 36 psig (2.48 bar) low pressure sensor and then adding your choice of 7 high pressure ranges
- External pressure module connection supports all pressure modules (29 ranges) for even more measurement capability
- Temperature-compensation ensures accuracy in field applications
- Pt100 RTD input for temperature measurement, accurate to 0.1°C (0.2°F) (Requires optional RTD probe sold separately)
- Measure 4-20 mA signals
- Internal 24 V Loop Power Supply can power a transmitter under test
- Measure up to 30 V DC
- Large graphic style LCD with backlight can be configured to display up to 3 inputs simultaneously (i.e. pressure 1, pressure 2, and RTD or any combination of inputs)
- Pressure displayed in the user’s choice of 19 engineering units
- Switch test on both pressure inputs, or external pressure module
- Operating mode layers support simple measurements to complex applications
- Up to five frequently used setups can be stored; last setup automatically recalled on power-up
- % error and damping functions
Fluke 721-1605 Dual Sensor Pressure Calibrator
Features
- Two isolated, stainless steel, pressure sensors with 0.025% f.s. accuracy
- Can be configured by selecting either a 16 psig (1.1 bar) or 36 psig (2.48 bar) low pressure sensor and then adding your choice of 7 high pressure ranges
- External pressure module connection supports all pressure modules (29 ranges) for even more measurement capability
- Temperature-compensation ensures accuracy in field applications
- Pt100 RTD input for temperature measurement, accurate to 0.1°C (0.2°F) (Requires optional RTD probe sold separately)
- Measure 4-20 mA signals
- Internal 24 V Loop Power Supply can power a transmitter under test
- Measure up to 30 V DC
- Large graphic style LCD with backlight can be configured to display up to 3 inputs simultaneously (i.e. pressure 1, pressure 2, and RTD or any combination of inputs)
- Pressure displayed in the user’s choice of 19 engineering units
- Switch test on both pressure inputs, or external pressure module
- Operating mode layers support simple measurements to complex applications
- Up to five frequently used setups can be stored; last setup automatically recalled on power-up
- % error and damping functions