Fluke 718EX-300 Intrinsically Safe Pressure Calibrator
Features
- Pressure Source and Milliamp Measurement to calibrate and maintain almost any pressure device
- Integrated pump is easily cleaned when accidently exposed to fluids that reduces cost of ownership and repairs and enables servicing the pump in the field
- Error % calculation for quicker pass/fail decision making in the field
- Best in class mA accuracy of 0.015 % for better measurement confidence and workload coverage
- Min/Max/Hold to capture changing measurements
- Switch test feature for quicker and more accurate pressure switch testing
- New 1 and 300 PSI pressure ranges mean fewer extra tools required
- 1, 30, 100 & 300 PSI ranges now available
Applications
- Pressure instrument calibration
- Pressure instrument Maintenance
- Petro-Chemical
- Oil and Gas
- Pharmaceutical
- Water and wastewater
- Food and Beverage
- Power Generation
Fluke 718Ex-30G Intrinsically Safe Pressure Calibrator
Features
- True RMS current and voltage measurements gives you accurate readings of non-sinusoidal waveforms
- Multimeter functions include AC/DC voltage, resistance, capacitance, frequency, diode and continuity
- Peak hold captures inrush currents and transients
- Data hold and Max/Min functions
- 4000-count backlit display
- Autoranging with manual range button
- Auto power off
- 1.7″ (43mm) jaw opening for conductors up to 750MCM or two 500MCM
- Complete with Type K thermocouple probe, test leads, 9V battery and belt holster
Fluke 719-100G Pressure Calibrator, 100 PSI
Features
- Measure and source mA with best in class 0.015% accuracy
- Precision pressure adjust vernier for accurate pressure calibration
- Variable release rate bleed valve for easy pressure adjustment
- Ideal performance for high accuracy transmitter calibration
- 30 PSI and 100 PSI pressure ranges
- Programmable pressure calibrator pump limit
- eliminates over-pressurization
- allows the user to program target pressures for pumping
- Extended pressure measurement range with any of 29 700Pxx Pressure Modules
- Source mA with simultaneous pressure measurement to test valves and I/Ps
- Simulate mA signals to troubleshoot 4-20 mA loops
- Test pressure switches with built in switch test function
- Power transmitters during test using 24 V loop supply with simultaneous mA measurement
- Pressure Calibrator includes proven cleanout ports reduce pump failures
Applications
- Petro-Chemical
- Oil and Gas
- Food and Beverage
- Pharmaceutical
- Test and Measurement
- Instrumentation
Fluke 719-30G Electric Pressure Calibrator, 30 PSI
Features
- Fluke 719 30G
- Range: -12 to 36 PSI
- Resolution: 0.001 PSI,
- Accuracy: up to 0.025%
- Fluke 719 100G
- Range: -12 to 120 PSI
- Resolution: 0.01 PSI
- Accuracy: up to 0.025%
- mA:
- Range: 0 to 24 mA
- Accuracy: 0.015 % Rdg + 2 counts
- Max load: 1000Ω; 750 Ω ohm in HART mode
- Pump to:
- 30 PSI in less than 15 seconds (1m of 1/8″ test hose)
- 100 PSI in less than 45 seconds (1m of 1/8″ test hose)
- 5000 pump cycles between rebuilds
- Pump life: 20,000 calibration cycle
- Safety: CSA C22.2 No. 1010.1:1992
- EMC: EN50082-1:1992 and EN55022:1994 Class B
Fluke 719PRO-150G Electric Pressure Calibrator, 150 PSI/10 Bar
Features
- Electric pump for one handed pressure calibration
- Best in class pressure measurement uncertainty of 0.025%
- Measure and source mA with best in class 0.015% accuracy
- Precision pressure adjust vernier for accurate pressure calibration
- Variable release rate bleed valve for easy pressure adjustment
- Programmable pressure calibrator pump limit: eliminates over-pressurization and allows the user to program target pressures for pumping
- Programmable 3-tiered display for maximum flexibility when displaying pressure, temperature, and electrical parameters of your choice
- Display backlight
- Damping, Min/Max, and % error function
- Source mA with simultaneous pressure measurement to test valves and I/Ps
- Simulate mA signals to troubleshoot 4-20 mA loops
- Test pressure switches with built in switch test function
- Power transmitters during test using 24 V loop supply with simultaneous mA measurement
- Precision temperature measurement with the addition of an accessory RTD probe (available as an option)
- Proven cleanout ports reduce pump failures
- Moisture trap included with the unit helps mitigates risk of moisture damage
Applications
- Petro-Chemical
- Oil and Gas
- Pharmaceutical
- Water and wastewater
- Food and Beverage
- Power Generation
-10%
Close
Fluke 71X Hose Kit
Fluke 71X Hose Kit Accessory Overview The Fluke 71X Hose Kit is compatible with the 717 and 718 calibrators 100 PSI
-10%
Close
Fluke 71XTrap Liquid and Dirt Trap
Liquid and dirt trap for use with Fluke 718 and 719Pro.
-10%
Close
Fluke 720RTD Probe
RTD probe for use with Fluke 721 and 719Pro.
-10%
Close
Fluke 720URTDA Universal RTD adapter
For use with the Fluke 719 and 721.
Fluke 721-1601 Dual Sensor Pressure Calibrator
Features
- Two isolated, stainless steel, pressure sensors with 0.025% f.s. accuracy
- Can be configured by selecting either a 16 psig (1.1 bar) or 36 psig (2.48 bar) low pressure sensor and then adding your choice of 7 high pressure ranges
- External pressure module connection supports all pressure modules (29 ranges) for even more measurement capability
- Temperature-compensation ensures accuracy in field applications
- Pt100 RTD input for temperature measurement, accurate to 0.1°C (0.2°F) (Requires optional RTD probe sold separately)
- Measure 4-20 mA signals
- Internal 24 V Loop Power Supply can power a transmitter under test
- Measure up to 30 V DC
- Large graphic style LCD with backlight can be configured to display up to 3 inputs simultaneously (i.e. pressure 1, pressure 2, and RTD or any combination of inputs)
- Pressure displayed in the user’s choice of 19 engineering units
- Switch test on both pressure inputs, or external pressure module
- Operating mode layers support simple measurements to complex applications
- Up to five frequently used setups can be stored; last setup automatically recalled on power-up
- % error and damping functions
Fluke 721-1603 Dual Sensor Pressure Calibrator
Features
- Two isolated, stainless steel, pressure sensors with 0.025% f.s. accuracy
- Can be configured by selecting either a 16 psig (1.1 bar) or 36 psig (2.48 bar) low pressure sensor and then adding your choice of 7 high pressure ranges
- External pressure module connection supports all pressure modules (29 ranges) for even more measurement capability
- Temperature-compensation ensures accuracy in field applications
- Pt100 RTD input for temperature measurement, accurate to 0.1°C (0.2°F) (Requires optional RTD probe sold separately)
- Measure 4-20 mA signals
- Internal 24 V Loop Power Supply can power a transmitter under test
- Measure up to 30 V DC
- Large graphic style LCD with backlight can be configured to display up to 3 inputs simultaneously (i.e. pressure 1, pressure 2, and RTD or any combination of inputs)
- Pressure displayed in the user’s choice of 19 engineering units
- Switch test on both pressure inputs, or external pressure module
- Operating mode layers support simple measurements to complex applications
- Up to five frequently used setups can be stored; last setup automatically recalled on power-up
- % error and damping functions
Fluke 721-1605 Dual Sensor Pressure Calibrator
Features
- Two isolated, stainless steel, pressure sensors with 0.025% f.s. accuracy
- Can be configured by selecting either a 16 psig (1.1 bar) or 36 psig (2.48 bar) low pressure sensor and then adding your choice of 7 high pressure ranges
- External pressure module connection supports all pressure modules (29 ranges) for even more measurement capability
- Temperature-compensation ensures accuracy in field applications
- Pt100 RTD input for temperature measurement, accurate to 0.1°C (0.2°F) (Requires optional RTD probe sold separately)
- Measure 4-20 mA signals
- Internal 24 V Loop Power Supply can power a transmitter under test
- Measure up to 30 V DC
- Large graphic style LCD with backlight can be configured to display up to 3 inputs simultaneously (i.e. pressure 1, pressure 2, and RTD or any combination of inputs)
- Pressure displayed in the user’s choice of 19 engineering units
- Switch test on both pressure inputs, or external pressure module
- Operating mode layers support simple measurements to complex applications
- Up to five frequently used setups can be stored; last setup automatically recalled on power-up
- % error and damping functions