Excluding GST 10%
Excluding GST 10%
Amprobe AT-6010 Advanced Wire Tracer Kit
$1,200.00 Original price was: $1,200.00.$1,080.00Current price is: $1,080.00.Excluding GST 10%
Amprobe AT-6010 Offers
With the AT-6010 advanced wire tracer kit, it is easier and safer to locate energized and de-energized wires, breakers and fuses. When the transmitter is connected to the circuit, the receiver easily detects the signal in the wires or cables behind walls, ceilings and floors. The transmitter works on energized and de-energized circuits up to 600 V AC/DC in Category I through Category III electrical environments, allowing for work directly on an energized circuit without the need to take equipment offline. The transmitter also features high signal mode for general tracing and a loop mode designed specifically for locating shorts, as well as two optimal tracing frequencies that are automatically activated based on the detected voltage.
Features
- Receiver:
- Tip sensor – to trace wires in tight spaces
- Large black and white LCD screen
- Energized/De-energized indicator
- Signal strength bar graph
- Sensitivity adjustment
- Transmitter:
- Compatible with standard test leads
- Voltage warning indicator
- HI mode for general wire tracing
- Loop mode for finding shorts
- Simple one button operation
- Large LCD Receiver screen with two digit readout, bar graph and sound to easily determine wire location
- Compatible with the CT-400 Signal Clamp accessory for inducing a tracing signal on the cable when there is no access to bare conductors
Applications
- Trace energized and de-energized wires
- Identify breakers and fuses
- Connect to GFCI protected circuits
- Find breaks and opens
- Find shorts
- Trace wires in metal conduit
- Trace non-metallic pipes and conduit
- Trace shielded wires
- Trace underground wires
- Trace low voltage wires and data cables
- Sort bundled wires
- Map a circuit with test leads
- Trace breakers on system with light dimmers
- Receiver:
Available on backorder
Related products
Fluke Amprobe ACD-3300 IND CAT IV TRMS Clamp Meter with Temperature
Excluding GST 10%
Product Features:
- Performs true-RMS measurements
- Measures AC current up to 1000 AC A
- Measures voltage up to 750V AC and 1000V DC
- Includes frequency, resistance and capacitance and duty cycle functions
- Uses included thermocouple to measure temperature up to 1832°F (1000°C)
- Peak hold and data hold functions
- Audible continuity and diode test
- Auto and manual ranging
- Auto power off
- Large backlit LCD display with bar-graph
- Accommodates conductors up to 2 in. (51mm) in diameter
- Safety rated to CAT IV 600 V, CAT III 1000 V
Amprobe ALC-110 Leakage Current Clamp
Excluding GST 10%
Product Features:
- Measures:
- Earth and differential leakage currents
- Leakage currents through the earth (PE) conductor
- Appliance current consumption without interruptions to the circuit
- Low influence of external low frequency magnetic fields: @ IN: 3.500 mA – 600.0 mA ≤ 30 A/m, operating class 2
- True-RMS measurements for accuracy when measuring complex, non-sinusoidal waveforms
- Mechanical jaw lock with 1.2 in. (30 mm) opening assures accuracy of low current measurements
- Highest resolution of 0.001 mA while measuring up to 60 A
- Broad frequency range 15 Hz to 1 kHz
- Selectable filters:
- Low Pass 50/60Hz filter to perform measurements on equipment driven by Variable Frequency Drives (VFDs) or affected by high frequency noise
- Appliance Filter to conduct leakage current measurements on appliances
- No filter
- Selectable limits: 0.25 mA, 0.5 mA, 3.5 mA, 10 mA, 12 mA
- Max readings and hold function
- High safety rating: CAT III 600 V
- Battery-saving design with an auto backlight off and auto power off
Applications
- Trace the source of earth leakage current
- Identify intermittent GFCI trips without switching equipment off
- Check a system for an electrical break of insulation where current is flowing to the ground
- Where industrial leakage current testing is required
- Measures:
Fluke Amprobe ACD-50NAV CAT IV 600 A TRMS Navigator Clamp Meter
Excluding GST 10%
Product Features:
- True-RMS technology improves accuracy in noisy environments
- Measures AC/DC voltage to 1000V and AC current to 600A
- Measures resistance, frequency and capacitance
- Measures power factor, total harmonics distortion (THD) and individual harmonics from 1 to 25
- Includes inrush current measurement and phase rotation indication for 3-phase motors
- Non-contact voltage detection enhances safety
- Low pass filter allows measurement of voltage and frequency for variable frequency drives
- Continuity beeper quickly identifies shorts and opens
- Large 1000 count display with active backlight and analog bar graph
- Min, max, and smart data hold
- Peak hold identifies spikes and transients
- In-jaw flashlight automatically lights when jaws open, illuminating dark panels and junction boxes
- Auto power off conserves battery life
- Maximum jaw opening accommodates conductors up to 1.45″ (37mm)
- Rubber overmold body absorbs shocks: drop proof to 4 ft. (1.2m)
- Meets CAT IV 600V /CAT III 1000V safety standard
Amprobe ACD-10 TRMS-PLUS 600 A Clamp Multimeter
Excluding GST 10%
- AC/DC Voltage to 600 V
- AC Current to 600 A
- Thin jaws, only 0.4″ (10 mm) thick
- Resistance to 40 MΩ
- Continuity buzzer
- Capacitance to 3000 uF
- Frequency measurement
- In rush current
- Hold maximum reading functions
- Accommodates conductors up to 1.02″ (26 mm) in diameter
- Auto ranging
- Auto power off
- Rubber over-molded case
- Overload protected
- True-rms measurement
Fluke Amprobe 35XP-A Digital Multimeter with Temperature
Excluding GST 10%
- Temperature measurement capability to 1000 °C/1832 °F (type-K thermocouple included)
- 600 V AC/600 V DC – highest voltage rating in this class of meter
- Capacitance for motor run/start test
- 0.1 μA resolution for flame sensor testing
- Frequency to 1 MHz
- Resistance to 40 MΩ
- Data hold freezes display
- Magne-Grip™ Holster
- VolTect™ non-contact voltage detector
- Low battery indication
Fluke Amprobe 38XR-A TRMS Digital Multimeter with Temperature
Excluding GST 10%
- Backlight, True-rms with with optical PC interface
- Frequency to 10 MHz,capacitance to 400 uF, temperature to 2372 °F
- Bright blue backlight
- 10 Amps AC/DC, fully safety fused
- Continuity beeper
- Min/max, average, relative, peak, and data hold
- Auto power off to save battery life
- Separate door for easy battery and fuse access
- Magne-Grip™ Holster with magnetic hanging strap
- Autoranging; display: 4-3/4 digit LCD, 10,000 counts with 41-segment analog bar graph
- Display update rate: 2/sec, nominal
- Power battery: 9 V NEDA 1604, JIS 006P, IEC 6F22
- Operating temperature: 0 °C to 45 °C at < 70 % R.H
- Input lead warning
Fluke Amprobe ACDC-52NAV AC/DC CAT IV 600 A TRMS Navigator Clamp Meter
Excluding GST 10%
Product Features:
- True-RMStechnology improves accuracy in noisy environments
- Measures AC and DC voltage to 1000V
- Measures AC and DC current to 600A
- Resistance, frequency, and capacitance measurements
- Power and power factor, total harmonics distortion (THD) and individual harmonics from 1 to 25
- Includes inrush current measurement and phase rotation indication for 3-phase motors
- Non-contact voltage detection enhances safety
- Low pass filter enables measuring voltage and frequency for variable frequency drives
- Continuity beeper quickly identifies shorts and opens
- Large backlit digital display with analog bar graph presents full picture
- Min, max and smart data hold
- Peak hold identifies spikes and transients
- In-jaw flashlight automatically lights when jaws open, illuminating dark panels and junction boxes
- Auto power off conserves battery life
- Maximum jaw opening accommodates conductors up to 1.45″ (37mm)
- Rubber overmold body absorbs shocks: drop proof to 4 ft. (1.2m)
- Meets CAT IV 600V /CAT III 1000V safety standards
Fluke Amprobe ACD-51NAV CAT IV 600 A TRMS Navigator Clamp Meter
Excluding GST 10%
Product Features:
- True-RMS technology improves accuracy in noisy environments
- Measures AC/DC voltage to 1000V and AC current to 600A
- Resistance, frequency, and capacitance measurements
- Measures power factor, total harmonics distortion (THD) and individual harmonics from 1 to 25
- Provides DC micro amps measurements to test flame sensors
- Includes inrush current measurement and phase rotation indication for 3-phase motors
- Measures temperature from -58 to 1832°F (-50 to 1000°C)
- Non-contact voltage detection enhances safety
- Low pass filter enables measuring voltage and frequency for variable frequency drives
- Continuity beeper quickly identifies shorts and opens
- Large backlit digital display with analog bar graph
- Min, max and smart data hold
- Peak hold identifies spikes and transients
- In-jaw flashlight automatically lights when jaws open, illuminating dark panels and junction boxes
- Auto power off conserves battery life
- Maximum jaw opening accommodates large conductors up to 1.45″ (37mm)
- Rubber overmold body absorbs shocks: drop proof to 4 ft. (1.2m)
- Safety rated to CAT IV