Amprobe AT-6010 Advanced Wire Tracer Kit
$1,200.00Excluding GST 10%
-
Amprobe AT-6010 Offers
With the AT-6010 advanced wire tracer kit, it is easier and safer to locate energized and de-energized wires, breakers and fuses. When the transmitter is connected to the circuit, the receiver easily detects the signal in the wires or cables behind walls, ceilings and floors. The transmitter works on energized and de-energized circuits up to 600 V AC/DC in Category I through Category III electrical environments, allowing for work directly on an energized circuit without the need to take equipment offline. The transmitter also features high signal mode for general tracing and a loop mode designed specifically for locating shorts, as well as two optimal tracing frequencies that are automatically activated based on the detected voltage.
Features
- Receiver:
- Tip sensor – to trace wires in tight spaces
- Large black and white LCD screen
- Energized/De-energized indicator
- Signal strength bar graph
- Sensitivity adjustment
- Transmitter:
- Compatible with standard test leads
- Voltage warning indicator
- HI mode for general wire tracing
- Loop mode for finding shorts
- Simple one button operation
- Large LCD Receiver screen with two digit readout, bar graph and sound to easily determine wire location
- Compatible with the CT-400 Signal Clamp accessory for inducing a tracing signal on the cable when there is no access to bare conductors
Applications
- Trace energized and de-energized wires
- Identify breakers and fuses
- Connect to GFCI protected circuits
- Find breaks and opens
- Find shorts
- Trace wires in metal conduit
- Trace non-metallic pipes and conduit
- Trace shielded wires
- Trace underground wires
- Trace low voltage wires and data cables
- Sort bundled wires
- Map a circuit with test leads
- Trace breakers on system with light dimmers
- Receiver:
Available on backorder
Related products
Fluke Amprobe 5XP-A AC/DC Compact Digital Multimeter with VolTect
Excluding GST 10%
- 27 ranges/10 functions
- Battery load test with 1.5 V and 9 V capabilities
- Data Hold
- Min/Max record minimum and maximum values
- VolTect™ non-contact voltage (NVC) detection
- Low battery indication
- Safety rated CAT II 600 V, CAT III 300 V
Fluke Amprobe ACD-23SW Swivel Clamp Meter
Excluding GST 10%
-
Product Features:
- Performs true-RMS measurement
- 180 degree rotating head for optimal display viewing
- Advanced VoltTect non-contact voltage detection
- Easy to use with slim jaw design and one hand operation
- Measures AC current up to 400A
- Measures AC and DC voltage up to 600V
- Resistance and capacitance measurement
- Audible continuity
- Temperature measurement with type-K thermocouple probe
- Auto and manual ranging respectively offer quick checks and precise measurements
- Accommodates conductors up to 1.18″ (30mm) in diameter
- Auto power off to extend battery life
- Includes data hold function
- Safety rated toCAT III 600 V
Fluke Amprobe ACDC-100 TRMS 1000 A AC/DC Clamp Meter
Excluding GST 10%
Product Features:
- Performs True-RMS measurements for accuracy
- Measures AC current to 800A and DC current to 1000A
- Measures AC and DC voltage to 600V
- Capacitance and resistance measurements
- Continuity beeper quickly identifies shorts and opens
- Relative zero mode displays difference between actual reading and stored reference value
- Data hold freezes reading on display for further analysis
- Diode test quickly finds voltage drops
- MAX capture function measures inrush current (30 mS response)
- Easy to read backlit digital display
- Auto power-off to conserve battery life
- Equipped with “third hand” test probe holder
- Rubber over-molded case absorbs shock and provides built-in probe storage
- Accommodates conductors up to 2.0″ (50mm) in diameter
- CAT III 600V rated
Fluke Amprobe ACDC-52NAV AC/DC CAT IV 600 A TRMS Navigator Clamp Meter
Excluding GST 10%
-
Product Features:
- True-RMStechnology improves accuracy in noisy environments
- Measures AC and DC voltage to 1000V
- Measures AC and DC current to 600A
- Resistance, frequency, and capacitance measurements
- Power and power factor, total harmonics distortion (THD) and individual harmonics from 1 to 25
- Includes inrush current measurement and phase rotation indication for 3-phase motors
- Non-contact voltage detection enhances safety
- Low pass filter enables measuring voltage and frequency for variable frequency drives
- Continuity beeper quickly identifies shorts and opens
- Large backlit digital display with analog bar graph presents full picture
- Min, max and smart data hold
- Peak hold identifies spikes and transients
- In-jaw flashlight automatically lights when jaws open, illuminating dark panels and junction boxes
- Auto power off conserves battery life
- Maximum jaw opening accommodates conductors up to 1.45″ (37mm)
- Rubber overmold body absorbs shocks: drop proof to 4 ft. (1.2m)
- Meets CAT IV 600V /CAT III 1000V safety standards
Fluke Amprobe ACD-3300 IND CAT IV TRMS Clamp Meter with Temperature
Excluding GST 10%
-
Product Features:
- Performs true-RMS measurements
- Measures AC current up to 1000 AC A
- Measures voltage up to 750V AC and 1000V DC
- Includes frequency, resistance and capacitance and duty cycle functions
- Uses included thermocouple to measure temperature up to 1832°F (1000°C)
- Peak hold and data hold functions
- Audible continuity and diode test
- Auto and manual ranging
- Auto power off
- Large backlit LCD display with bar-graph
- Accommodates conductors up to 2 in. (51mm) in diameter
- Safety rated to CAT IV 600 V, CAT III 1000 V
Fluke Amprobe ACD-14 TRMS-PLUS Dual Display Digital Clamp Multimeter
Excluding GST 10%
-
Product Features:
- Dual displays allow for simultaneous reading of amperage and voltage
- True-RMS for precise measurement results
- Thin jaws facilitate access in tight measurement spaces
- AC current to 600A
- AC and DC voltage to 600V
- Resistance to 40MΩ
- Capacitance to 3000 µF
- Temperature measurement with K-type thermocouple probe
- Frequency measurement
- In rush current measurement
- Diode test and continuity buzzer
- Micro Amps measurement for testing flame sensors
- Hold and maximum reading functions
- Accommodates conductors up to 28 mm (1.1″) in diameter
- Auto ranging instantly selects correct range
- Auto power off and low battery indication
- Rubber over-molded case
Amprobe ACD-10 TRMS-PLUS 600 A Clamp Multimeter
Excluding GST 10%
- AC/DC Voltage to 600 V
- AC Current to 600 A
- Thin jaws, only 0.4″ (10 mm) thick
- Resistance to 40 MΩ
- Continuity buzzer
- Capacitance to 3000 uF
- Frequency measurement
- In rush current
- Hold maximum reading functions
- Accommodates conductors up to 1.02″ (26 mm) in diameter
- Auto ranging
- Auto power off
- Rubber over-molded case
- Overload protected
- True-rms measurement
Amprobe ALC-110 Leakage Current Clamp
Excluding GST 10%
-
Product Features:
- Measures:
- Earth and differential leakage currents
- Leakage currents through the earth (PE) conductor
- Appliance current consumption without interruptions to the circuit
- Low influence of external low frequency magnetic fields: @ IN: 3.500 mA – 600.0 mA ≤ 30 A/m, operating class 2
- True-RMS measurements for accuracy when measuring complex, non-sinusoidal waveforms
- Mechanical jaw lock with 1.2 in. (30 mm) opening assures accuracy of low current measurements
- Highest resolution of 0.001 mA while measuring up to 60 A
- Broad frequency range 15 Hz to 1 kHz
- Selectable filters:
- Low Pass 50/60Hz filter to perform measurements on equipment driven by Variable Frequency Drives (VFDs) or affected by high frequency noise
- Appliance Filter to conduct leakage current measurements on appliances
- No filter
- Selectable limits: 0.25 mA, 0.5 mA, 3.5 mA, 10 mA, 12 mA
- Max readings and hold function
- High safety rating: CAT III 600 V
- Battery-saving design with an auto backlight off and auto power off
Applications
- Trace the source of earth leakage current
- Identify intermittent GFCI trips without switching equipment off
- Check a system for an electrical break of insulation where current is flowing to the ground
- Where industrial leakage current testing is required
- Measures: