“Fluke Amprobe 5XP-A AC/DC Compact Digital Multimeter with VolTect” has been added to your cart. View cart
Previous product
Back to products
Fluke Amprobe DC205C Deluxe Hard Shell Case
$122.00
Excluding GST 10%
Next product
Fluke Amprobe DL248D Test Leads
$190.00
Excluding GST 10%
Fluke Amprobe DGC-1000A Clamp Ground Resistance Tester
$4,801.00Excluding GST 10%
- Accurate ground resistance measurement from 0.025 to 1500 Ohms
- True-rms current measurement including leakage current
- Accurate readings regardless of power quality in less than 10 seconds
- Continuity beep if the resistance is lower than 40.00 Ohms
- Simple and easy to use, no test leads or auxiliary electrodes necessary
- Data logging capability – 116 records
- Individual data point recording
- User selectable high low ohm audible alarms
- Auto power off (can be disabled)
- Low battery indicator
- Large LCD display
Available on backorder
SKU: 2731217
Category: Amprobe - Test Instruments
Related products
Fluke Amprobe ACDC-100 1000 A AC/DC Clamp Meter
$343.00
Excluding GST 10%
- Large, easy to read LCD display
- Auto and manual ranging
- Relative zero mode
- Auto power off
- Data hold
- MAX capture function for inrush current measurements (30 mS response)
- Diode test
- Audible continuity
- Accommodates conductors up to 2.0″ (50 mm) in diameter
- “Third hand” – test probe holder
- Rubber over-molded case with built-in probes storage
Fluke Amprobe 30XR-A Auto Ranging Digital Multimeter with VolTect
$219.00
Excluding GST 10%
-
Product Features:
- Non-contact voltage detector
- Separate door for easy battery and fuse access
- Manual ranging; display: 3-1/2 digit LCD, 1999 counts
- Display update rate: 2.5/sec, nominal
- Power battery: 9 V NEDA 1604, JIS 006P, IEC 6F22
- Operating temperature: 0 °C to 45 °C at < 70 % R.H.
- Storage temperature: -20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter
- Low battery indication
- Overrange indication
- Min/max and data Hold
- 600V AC
- Magne-Grip Holster With Magnetic Hanging Strap
- 600V AC/DC
- 10 Amps AC/DC, Fully Safety Fused
- Continuity Beeper
Fluke Amprobe 5XP-A AC/DC Compact Digital Multimeter with VolTect
$143.00
Excluding GST 10%
- 27 ranges/10 functions
- Battery load test with 1.5 V and 9 V capabilities
- Data Hold
- Min/Max record minimum and maximum values
- VolTect™ non-contact voltage (NVC) detection
- Low battery indication
- Safety rated CAT II 600 V, CAT III 300 V
Fluke Amprobe AD40B Mini-Clamp Ammeter
$204.00
Excluding GST 10%
-
Product Features:
- Low-cost, miniature digital ammeter
- 400 A AC range
- Maximum jaw opening: 25.4 mm
- 4000-count display with bargraph
- Autoranging
- Data hold
- Auto-off
- 3 3/4 digit LCD (max reading 3999);
- Overrange indication: “OL indicated
- Power supply: two (2) 1.5V AAA batteries
Amprobe AC50A AC Leakage Clamp Meter
$913.00
Excluding GST 10%
-
Product Features:
- AC current measurement to 60A
- Leakage current measurement with resolution of 0.01mA
- AC voltage to 400V
- Resistance measurement and continuity beeper
- Min/max control to see largest or smallest values in series of measurements
- Relative value measurement to determine differentials
- Data hold to freeze measurement value on display
- Digital display with analog bargraph
- Jaw opening: 30 mm (1.2 in)
- Auto-power off to save battery life
- Minimum resolution 0.01mA
Fluke Amprobe ACD-10 PLUS 600A Clamp Multimeter
$343.00
Excluding GST 10%
Amprobe ACD-10 PLUS 600A Clamp Multimeter
- Measures AC and DC voltage to 600V and AC current to 600A to handle residential/commercial and small industrial applications
- Thin jaws, only 10mm (0.4″) thick make it easier to maneuver between tightly packed conductors
- Measures frequency, resistance, and capacitance
- Features continuity beeper to quickly find opens and shorts
- Accommodates conductors up to 1.0″ (25mm) in diameter
- Auto ranging saves time by instantly selecting correct range
- Auto power off to conserve battery life
- Rubber over-molded case absorbs shock
- Includes test leads, battery (installed), soft carrying pouch, and users manual
Fluke Amprobe ACD-14 PLUS Dual Display Clamp Multimeter with Temperature
$343.00
Excluding GST 10%
-
Product Features:
- Dual displays permit simultaneous reading of amps and volts
- Measurement ranges include:
- AC current to 600A
- AC and DC voltage to 600V
- Capacitance to 3000 µF
- Resistance to 40MΩ
- Frequency to 40kHz
- Measures temperature with included K-type thermocouple probe
- Includes micro amps measurement for testing flame sensors
- Diode test quickly finds voltage drops
- Continuity beeper detects opens and shorts
- Autoranging feature instantly selects correct range
- Hold and maximum reading functions
- Thin jaws make it easier to access conductors in tight spaces
- Accommodates conductors up to 25 mm (1.0″) in diameter
- Auto power off and low battery indication help extend battery life
- Rubber, over-molded case absorbs shock
Amprobe ALC-110 Leakage Current Clamp
$1,098.00
Excluding GST 10%
-
Product Features:
- Measures:
- Earth and differential leakage currents
- Leakage currents through the earth (PE) conductor
- Appliance current consumption without interruptions to the circuit
- Low influence of external low frequency magnetic fields: @ IN: 3.500 mA – 600.0 mA ≤ 30 A/m, operating class 2
- True-RMS measurements for accuracy when measuring complex, non-sinusoidal waveforms
- Mechanical jaw lock with 1.2 in. (30 mm) opening assures accuracy of low current measurements
- Highest resolution of 0.001 mA while measuring up to 60 A
- Broad frequency range 15 Hz to 1 kHz
- Selectable filters:
- Low Pass 50/60Hz filter to perform measurements on equipment driven by Variable Frequency Drives (VFDs) or affected by high frequency noise
- Appliance Filter to conduct leakage current measurements on appliances
- No filter
- Selectable limits: 0.25 mA, 0.5 mA, 3.5 mA, 10 mA, 12 mA
- Max readings and hold function
- High safety rating: CAT III 600 V
- Battery-saving design with an auto backlight off and auto power off
Applications
- Trace the source of earth leakage current
- Identify intermittent GFCI trips without switching equipment off
- Check a system for an electrical break of insulation where current is flowing to the ground
- Where industrial leakage current testing is required
- Measures: