Desmo LT240A15 CAT IV 600V Single Phase Load tester,used as an electrical load on kWh power meters when testing to ensure the correct operation and functionality of the meters. Incorporates fused probes with silicon leads and is housed in a compact body. It is protected by an automatic thermal cut-out switch. Specifications are; Voltage: 240 – 250V max. 1Ø Load: 1100W – 4.5amp. Internal Fusing: 7amp. Safety Rating: Cat IV 600V – Cat III 1000V. Compliant to: AS: 61010.1: 2003. Weight: 420gm. Leads: Silicon with internal white wear indicator layer. Test Probes: Cat III 1000V. Motor: 1100W with thermal cut-out. Grills: Black Nylon 15% Glass Filled. Cable Grommet: TPE 90A Shore. Body: PC-ABS Fire Retardant – spark finish. Hook: Polished 316 S/S that allows hands free operation
Excluding GST 10%
Excluding GST 10%
DESMO LT240A15 – CAT IV Single Phase Loadtester
$265.00Excluding GST 10%
Features & Benefits
- Voltage: 240 – 250V max. 1Ø
- Load: 1100W – 4.5amp.
- Internal Fusing: 7amp.
- Safety Rating: Cat IV 600V – Cat III 1000V.
- Compliant to: AS: 61010.1: 2003.
- Weight: 420gm.
- Leads: Silicon with internal white wear indicator layer.
- Test Probes: Cat III 1000V.
- Motor: 1100W with thermal cut-out.
- Grills: Black Nylon 15% Glass Filled.
- Cable Grommet: TPE 90A Shore.
- Body: PC-ABS Fire Retardant – spark finish.
- Hook: Polished 316 S/S that allows hands free operation.
- Product Code: LT240A15
Available on backorder
Related products
88-5 / 88V – Fluke Automotive Multimeter
Excluding GST 10%
Product overview: Fluke 88V Deluxe Automotive Multimeter
The Fluke 88V meter has measurement functions, troubleshooting features, and accuracy levels needed to solve problems on conventional and hybrid vehicles. The 88V is the most powerful automotive multimeter ever offered by Fluke. In addition to standard multimeter features such as the ability to measure voltage, current, continuity, and resistance, the 88V can perform:
Pulse width
Duty cycle
Min/Max/Average recording
Diode tests
The pulse width function provides millisecond resolution for troubleshooting fuel injectors.
Automotive measurements
The 88V meter can take care of many automotive needs, getting into more of the digital multimeters measurement capabilities – it can measure voltage up to 1000 V AC and DC, current up to 10 A, 20 A for up to 30 seconds and frequency to 200 kHz and % duty cycle. Add those features to RPM measurements with optional inductive pickup and millisecond pulse width measurements for fuel injectors to name a few. The 88V comes packed with the functions you need:
Temperature measurements with optional temperature probe
Analog bar graph to track changing or unstable signals
Min/Max/Average recording with Min/Max Alert to capture variations automatically
Peak Min/Max to record transients as fast as 250 μs
88V multimeter designed for the garage
While working in a garage, the large display digits can help you focus on the vehicle while still being able to read the numbers. Plus, the two-level bright white backlight offers the additional visibility you may need.
An optional magnetic hanger lets you hang the meter from most steel surfaces for easy set-up and viewing. The 88V is designed to be used in high energy environments like those found on hybrid vehicles.
The product is supported by a limited lifetime warranty.
Fluke Amprobe USB-KIT3 Download Module for Amprobe Precision Multimeters
Excluding GST 10%
Product Features:
- PC Interface Kit
- Download software with connection cable
- For Amprobe Multimeters
Fluke LVD1A Volt Light
Excluding GST 10%
- Built-in flashlight
- Detector glows blue when AC voltage is present
- Detector glows red when it is at the source
M1120 NST Neutral Supply Tester Kit
Excluding GST 10%
LCD screen to display measurement results and messages.
CAT IV 600V instrument and lead set compliance.
IP54 moisture and dust ingress rating.
Compact hand held unit housed in a lightweight heavy-duty case
Uniquely self powered passive device.
Power is taken directly from the user’s connections.
3 LED indicators and an LCD screen for status and measurement information.
An audible alarm is fitted internally as a secondary indicator. To indicate a pass at the end of the measurement cycle or a measurement failure.
Fluke VisiFault Visual Fault Locator
Excluding GST 10%
- Locates visual faults including tight bends, breaks and bad connectors
- Accelerates end-to-end fiber checks
- Easily verifies polarity and identifies fibers
- Features continuous and flashing modes
- Ergonomic case survives drops, impacts and vibrations
Fluke 732C and 734C DC Voltage Reference Standards
The simple way to maintain and disseminate the volt
The Fluke Calibration 732C DC Voltage Reference Standard is a RoHS compliant direct voltage reference used to maintain the volt in primary and secondary standards laboratories. Individual 732C voltage standards provide 10 V, 1 V, and 0.1 V outputs and may be transported easily to remote locations while the dc reference is maintained in the laboratory. The 734C DC Voltage Reference Standard consists of four electrically and mechanically independent 732C DC Reference Standards and a rack-width enclosure. Two model families, Base and Select, differ in that the Select models are two times more stable than the Base models.
Because each 732C in the 734C DC Reference Standard is based on the same architecture pioneered in the popular 732A DC Voltage Standard—the first standards lab quality 10 V electronic reference—you can rely on it to provide the same high stability and predictable drift rate you’ve come to expect, in a smaller, more portable package identical to the 732B DC Voltage Standard. The 734C is also compatible with 732B DC standards and can support any combination of 732 B and C models. Similarly, 734A can be used with the newer 732C voltage standards, providing the ultimate flexibility and maximizing asset utilization.
To simplify support of your 734C, Fluke Calibration offers a variety of calibration services to assign values and predicted performance for each of the 10 V outputs, traceable to national standards and to the Fluke Calibration 10 V Josephson Array.
Fluke Amprobe ULD-420 ULTRASONIC LEAK DETECTOR WITH TRANSMITTER
Excluding GST 10%
Product Features:
- 20 kHz to 90 kHz frequency range: optimal range for detecting a variety of leakage events
- Adjustable Transmitter signal strength for accurate leak pinpointing
- 3 filters to remove main noise frequencies in noisy environments
- 2.5″ LCD display with bargraph
- Adjustable Receiver Sensitivity
- Industrial headphones to help identify the source of the leak
- Parabola accessory directs the ultrasound towards the sensor
- Detachable Tubular Extension provides additional reach in hard to reach areas
Fluke EI-162AC Clip on Current Transformer
Excluding GST 10%
Fluke Clip-On Current Transformer Features
- Performs selective and stakeless testing
- Inner diameter: 2 in.
- For use with Models 1623 and 1625