The Fluke 729 Automatic Pressure Calibrator has been designed specifically with process technicians in mind to simplify the pressure calibration process and provide faster, more accurate test results.
Excluding GST 10%
Excluding GST 10%
Fluke 729 Pressure Calibrator 300G FC, 300 PSI, 20 Bar with Fluke Connect
$16,672.00Excluding GST 10%
Available on backorder
Related products
Fluke Amprobe MTL-EARTH 4 Earth Roads With Leads
Excluding GST 10%
- 4 Earth Roads with Leads
- For use with the Amprobe DM-III Multitest and DM-III Multitest Flex Power Quality Recorders
DESMO LT240A15 – CAT IV Single Phase Loadtester
Excluding GST 10%
Features & Benefits
- Voltage: 240 – 250V max. 1Ø
- Load: 1100W – 4.5amp.
- Internal Fusing: 7amp.
- Safety Rating: Cat IV 600V – Cat III 1000V.
- Compliant to: AS: 61010.1: 2003.
- Weight: 420gm.
- Leads: Silicon with internal white wear indicator layer.
- Test Probes: Cat III 1000V.
- Motor: 1100W with thermal cut-out.
- Grills: Black Nylon 15% Glass Filled.
- Cable Grommet: TPE 90A Shore.
- Body: PC-ABS Fire Retardant – spark finish.
- Hook: Polished 316 S/S that allows hands free operation.
- Product Code: LT240A15
M1120 NST Neutral Supply Tester Kit
Excluding GST 10%
LCD screen to display measurement results and messages.
CAT IV 600V instrument and lead set compliance.
IP54 moisture and dust ingress rating.
Compact hand held unit housed in a lightweight heavy-duty case
Uniquely self powered passive device.
Power is taken directly from the user’s connections.
3 LED indicators and an LCD screen for status and measurement information.
An audible alarm is fitted internally as a secondary indicator. To indicate a pass at the end of the measurement cycle or a measurement failure.
Fluke Amprobe ACD-14-PRO Dual Display 600 A TRMS Clamp Multimeter
Excluding GST 10%
Product Features:
- Large LCD with dual display can show voltage and amps simultaneously
- True-RMS for accurate voltage measurements in noisy environments
- Low pass filter for current and voltage measurements on variable frequency drives
- Amp-Tip function for precise low current measurement down to 0.1 amp
- Ideal for HVAC applications with temperature, DC micro-amps and capacitance measurements
- Performs non-contact voltage detection (NCV)
- In-rush current measurement
- Audible continuity and diode test
- Data hold function
- Auto ranging instantly selects correct range
- Auto power off and low battery indicator
- Safety rated to CAT III 600 V
Fluke VisiFault Visual Fault Locator
Excluding GST 10%
- Locates visual faults including tight bends, breaks and bad connectors
- Accelerates end-to-end fiber checks
- Easily verifies polarity and identifies fibers
- Features continuous and flashing modes
- Ergonomic case survives drops, impacts and vibrations
Fluke Amprobe ULD-420 ULTRASONIC LEAK DETECTOR WITH TRANSMITTER
Excluding GST 10%
Product Features:
- 20 kHz to 90 kHz frequency range: optimal range for detecting a variety of leakage events
- Adjustable Transmitter signal strength for accurate leak pinpointing
- 3 filters to remove main noise frequencies in noisy environments
- 2.5″ LCD display with bargraph
- Adjustable Receiver Sensitivity
- Industrial headphones to help identify the source of the leak
- Parabola accessory directs the ultrasound towards the sensor
- Detachable Tubular Extension provides additional reach in hard to reach areas
Fluke 732C and 734C DC Voltage Reference Standards
The simple way to maintain and disseminate the volt
The Fluke Calibration 732C DC Voltage Reference Standard is a RoHS compliant direct voltage reference used to maintain the volt in primary and secondary standards laboratories. Individual 732C voltage standards provide 10 V, 1 V, and 0.1 V outputs and may be transported easily to remote locations while the dc reference is maintained in the laboratory. The 734C DC Voltage Reference Standard consists of four electrically and mechanically independent 732C DC Reference Standards and a rack-width enclosure. Two model families, Base and Select, differ in that the Select models are two times more stable than the Base models.
Because each 732C in the 734C DC Reference Standard is based on the same architecture pioneered in the popular 732A DC Voltage Standard—the first standards lab quality 10 V electronic reference—you can rely on it to provide the same high stability and predictable drift rate you’ve come to expect, in a smaller, more portable package identical to the 732B DC Voltage Standard. The 734C is also compatible with 732B DC standards and can support any combination of 732 B and C models. Similarly, 734A can be used with the newer 732C voltage standards, providing the ultimate flexibility and maximizing asset utilization.
To simplify support of your 734C, Fluke Calibration offers a variety of calibration services to assign values and predicted performance for each of the 10 V outputs, traceable to national standards and to the Fluke Calibration 10 V Josephson Array.
Fluke 752A Reference Divider
- 10:1 and 100:1 divider outputs
- Output uncertainty 0.2 ppm and 0.5 ppm
- Built-in calibration bridge
- Dynamic Resistor Matching™
- System switching for ease of use
- Operating modes