The Fluke 729 Automatic Pressure Calibrator has been designed specifically with process technicians in mind to simplify the pressure calibration process and provide faster, more accurate test results.
Excluding GST 10%
Excluding GST 10%
Fluke 729 Pressure Calibrator 300G FC, 300 PSI, 20 Bar with Fluke Connect
$15,581.00Excluding GST 10%
Available on backorder
Related products
Fluke Amprobe ACD-14-PRO Dual Display 600 A TRMS Clamp Multimeter
Excluding GST 10%
Product Features:
- Large LCD with dual display can show voltage and amps simultaneously
- True-RMS for accurate voltage measurements in noisy environments
- Low pass filter for current and voltage measurements on variable frequency drives
- Amp-Tip function for precise low current measurement down to 0.1 amp
- Ideal for HVAC applications with temperature, DC micro-amps and capacitance measurements
- Performs non-contact voltage detection (NCV)
- In-rush current measurement
- Audible continuity and diode test
- Data hold function
- Auto ranging instantly selects correct range
- Auto power off and low battery indicator
- Safety rated to CAT III 600 V
Fluke Amprobe ULD-420 ULTRASONIC LEAK DETECTOR WITH TRANSMITTER
Excluding GST 10%
Product Features:
- 20 kHz to 90 kHz frequency range: optimal range for detecting a variety of leakage events
- Adjustable Transmitter signal strength for accurate leak pinpointing
- 3 filters to remove main noise frequencies in noisy environments
- 2.5″ LCD display with bargraph
- Adjustable Receiver Sensitivity
- Industrial headphones to help identify the source of the leak
- Parabola accessory directs the ultrasound towards the sensor
- Detachable Tubular Extension provides additional reach in hard to reach areas
DESMO LT240A15 – CAT IV Single Phase Loadtester
Excluding GST 10%
Features & Benefits
- Voltage: 240 – 250V max. 1Ø
- Load: 1100W – 4.5amp.
- Internal Fusing: 7amp.
- Safety Rating: Cat IV 600V – Cat III 1000V.
- Compliant to: AS: 61010.1: 2003.
- Weight: 420gm.
- Leads: Silicon with internal white wear indicator layer.
- Test Probes: Cat III 1000V.
- Motor: 1100W with thermal cut-out.
- Grills: Black Nylon 15% Glass Filled.
- Cable Grommet: TPE 90A Shore.
- Body: PC-ABS Fire Retardant – spark finish.
- Hook: Polished 316 S/S that allows hands free operation.
- Product Code: LT240A15
Fluke LVD1A Volt Light
Excluding GST 10%
- Built-in flashlight
- Detector glows blue when AC voltage is present
- Detector glows red when it is at the source
Fluke PRV240 Proving Unit, 240V
Excluding GST 10%
Fluke PRV240 Offers
Reduces the risk of shock and arc flash by removing unnecessary exposure to a potentially hazardous electrical environment while verifying the functionality of test tools before and after absence or presence of voltage is checked.
Features
- Sources both AC and DC steady-state voltage – supplies 240 V DC/AC
- A single LED indicates functionality, making this unit a simple-to-use solution for verification of your test tool
- Compatible with both high impedance or low impedance multimeters, clamp meters or two pole testers
- Voltage is sourced through recessed contacts that are activated when tested probes are inserted to avoid accidental contact
- Long battery life – 5,000 tests per set of four AA batteries
Test Before Touch
Provides a safe method to verify that your electrical test tool is operating properly before you conduct further tests. The concept of “Test Before Touch” (TBT) or three point test method involves testing your meter against a known live source before and after the actual measurement. This sequence verifies that your test tool is operating properly during the actual measurement.
Designed for safety and compliance
Safe and easy method for verifying proper operation of your test tool before attempting to test for either an energized source or a de-energized source without the need for cumbersome PPE, or in cases where no known voltage source is available. Your environment may still require minimal PPE such as hard, safety glasses or earplugs when using a proving unit.
Fluke Amprobe TM-SWA CABLE AND SOFTWARE FOR TMD90 AND TMA10
Excluding GST 10%
Amprobe TM-SWA Cable and Software for TMD90A and TMA10A
Fluke Amprobe USB-KIT2 Download Module for Amprobe Clamps
Excluding GST 10%
Product Features:
- Software for Transferring Data to PC
- Includes Connection Cable
- For Amprobe Clamp Meters
Fluke 732C and 734C DC Voltage Reference Standards
The simple way to maintain and disseminate the volt
The Fluke Calibration 732C DC Voltage Reference Standard is a RoHS compliant direct voltage reference used to maintain the volt in primary and secondary standards laboratories. Individual 732C voltage standards provide 10 V, 1 V, and 0.1 V outputs and may be transported easily to remote locations while the dc reference is maintained in the laboratory. The 734C DC Voltage Reference Standard consists of four electrically and mechanically independent 732C DC Reference Standards and a rack-width enclosure. Two model families, Base and Select, differ in that the Select models are two times more stable than the Base models.
Because each 732C in the 734C DC Reference Standard is based on the same architecture pioneered in the popular 732A DC Voltage Standard—the first standards lab quality 10 V electronic reference—you can rely on it to provide the same high stability and predictable drift rate you’ve come to expect, in a smaller, more portable package identical to the 732B DC Voltage Standard. The 734C is also compatible with 732B DC standards and can support any combination of 732 B and C models. Similarly, 734A can be used with the newer 732C voltage standards, providing the ultimate flexibility and maximizing asset utilization.
To simplify support of your 734C, Fluke Calibration offers a variety of calibration services to assign values and predicted performance for each of the 10 V outputs, traceable to national standards and to the Fluke Calibration 10 V Josephson Array.