Excluding GST 10%
Excluding GST 10%
Fluke Amprobe AT-6030 Advanced Wire Tracer Kit
$2,206.00Excluding GST 10%
Key features
- Work directly on an energized circuit without the need to take equipment offline
- Save time searching for energized and de-energized wires hidden behind walls, ceilings and floors
- Pinpoint wire location with the large color LCD Receiver screen featuring four unique modes
- Identify breakers and fuses, as well as the location of a break, open or short
- Non-Contact Voltage Detection utilizes passive tracing without the Transmitter to verify if a wire is energized
- Includes the CT-400 Signal Clamp accessory for inducing a tracing signal on the cable when there is no access to bare conductors
Available on backorder
Related products
Fluke Amprobe ACD-14-PRO Dual Display 600 A TRMS Clamp Multimeter
Excluding GST 10%
Product Features:
- Large LCD with dual display can show voltage and amps simultaneously
- True-RMS for accurate voltage measurements in noisy environments
- Low pass filter for current and voltage measurements on variable frequency drives
- Amp-Tip function for precise low current measurement down to 0.1 amp
- Ideal for HVAC applications with temperature, DC micro-amps and capacitance measurements
- Performs non-contact voltage detection (NCV)
- In-rush current measurement
- Audible continuity and diode test
- Data hold function
- Auto ranging instantly selects correct range
- Auto power off and low battery indicator
- Safety rated to CAT III 600 V
Fluke 752A Reference Divider
- 10:1 and 100:1 divider outputs
- Output uncertainty 0.2 ppm and 0.5 ppm
- Built-in calibration bridge
- Dynamic Resistor Matching™
- System switching for ease of use
- Operating modes
Fluke 732C and 734C DC Voltage Reference Standards
The simple way to maintain and disseminate the volt
The Fluke Calibration 732C DC Voltage Reference Standard is a RoHS compliant direct voltage reference used to maintain the volt in primary and secondary standards laboratories. Individual 732C voltage standards provide 10 V, 1 V, and 0.1 V outputs and may be transported easily to remote locations while the dc reference is maintained in the laboratory. The 734C DC Voltage Reference Standard consists of four electrically and mechanically independent 732C DC Reference Standards and a rack-width enclosure. Two model families, Base and Select, differ in that the Select models are two times more stable than the Base models.
Because each 732C in the 734C DC Reference Standard is based on the same architecture pioneered in the popular 732A DC Voltage Standard—the first standards lab quality 10 V electronic reference—you can rely on it to provide the same high stability and predictable drift rate you’ve come to expect, in a smaller, more portable package identical to the 732B DC Voltage Standard. The 734C is also compatible with 732B DC standards and can support any combination of 732 B and C models. Similarly, 734A can be used with the newer 732C voltage standards, providing the ultimate flexibility and maximizing asset utilization.
To simplify support of your 734C, Fluke Calibration offers a variety of calibration services to assign values and predicted performance for each of the 10 V outputs, traceable to national standards and to the Fluke Calibration 10 V Josephson Array.
Fluke Amprobe UAT-620 UNDERGROUND UTILITY LOCATOR KIT W/CLAMP
Excluding GST 10%
Product Features:
- Multiple tracing modes allow you to locate and trace energized and de-energized utilities in several applications
- Intuitive Transmitter automatically chooses correct locating function based on connected accessory and includes selectable 8/33 kHz frequencies
- Receiver’s high-contrast display allows for clear viewing in full sunlight and features automatic backlight for shaded and dark areas
- Rated CAT IV 600 V, ensuring safety when working with energized cables
- Semi-automatic gain control quickly detects tracing signal and allows precise adjustment of receiver sensitivity
- Accurate depth measurement to 20 ft
- Rugged, durable construction
- Water and dust resistant to IP54
- Drop proof to 3.28 ft (1 m)
- Signal Clamp induces signal without making electrical contact
- Ground fault locating with optional A-Frame accessory (AF-600)
- Comes as complete kit, ready for use
- Three testing modes:
- Passive power mode (50/60 Hz) – Tracing energized lines conducting current (no Transmitter necessary)
- Passive radio mode (RF) – Using surrounding radio waves to trace underground utilities (no Transmitter necessary)
- Active mode – Using UAT-600-T Transmitter
- Three active modes with UAT-600-T Transmitter:
- Induction – Transmitter will automatically start to radiate signal around it with internal antenna, used for tracing individual cables where there is no access to line to connect test leads or clamp
- Direct connection with test leads – Most reliable method to trace individual cable or pipe
- Clamp – Provides efficient and safe method of applying locate signal to cable, where it is not possible or safe to gain access to cable for making electrical contact
- Main applications:
- Locate energized 50/60 Hz cables carrying current
- Identify location of all metallic utilities, pipes* or cables (energized or de-energized)
- Trace individual pipes* or cables (energized or de-energized)
- *Tracing of non-metallic pipes and conduits is possible after inserting metal fish tape or cable
- Special applications:
- Two frequency options: 8 kHz and 33 kHz
- Locate non-metallic pipes and sewer lines
- Take depth and current measurements
- Measure voltage, resistance and output current
- Advanced locating with two people
- Locate ground faults with the AF-600 A-Frame accessory
Applications
- Commercial and Residential Construction Contractors
- Water, Gas and Electric Installation and Repair Crews
- Pipe Laying Contractors
- Cable TV and Telecommunication Companies
- Electricians and General Contractors
Fluke PRV240 Proving Unit, 240V
Excluding GST 10%
Fluke PRV240 Offers
Reduces the risk of shock and arc flash by removing unnecessary exposure to a potentially hazardous electrical environment while verifying the functionality of test tools before and after absence or presence of voltage is checked.
Features
- Sources both AC and DC steady-state voltage – supplies 240 V DC/AC
- A single LED indicates functionality, making this unit a simple-to-use solution for verification of your test tool
- Compatible with both high impedance or low impedance multimeters, clamp meters or two pole testers
- Voltage is sourced through recessed contacts that are activated when tested probes are inserted to avoid accidental contact
- Long battery life – 5,000 tests per set of four AA batteries
Test Before Touch
Provides a safe method to verify that your electrical test tool is operating properly before you conduct further tests. The concept of “Test Before Touch” (TBT) or three point test method involves testing your meter against a known live source before and after the actual measurement. This sequence verifies that your test tool is operating properly during the actual measurement.
Designed for safety and compliance
Safe and easy method for verifying proper operation of your test tool before attempting to test for either an energized source or a de-energized source without the need for cumbersome PPE, or in cases where no known voltage source is available. Your environment may still require minimal PPE such as hard, safety glasses or earplugs when using a proving unit.
Fluke VisiFault Visual Fault Locator
Excluding GST 10%
- Locates visual faults including tight bends, breaks and bad connectors
- Accelerates end-to-end fiber checks
- Easily verifies polarity and identifies fibers
- Features continuous and flashing modes
- Ergonomic case survives drops, impacts and vibrations
DESMO LT240A15 – CAT IV Single Phase Loadtester
Excluding GST 10%
Features & Benefits
- Voltage: 240 – 250V max. 1Ø
- Load: 1100W – 4.5amp.
- Internal Fusing: 7amp.
- Safety Rating: Cat IV 600V – Cat III 1000V.
- Compliant to: AS: 61010.1: 2003.
- Weight: 420gm.
- Leads: Silicon with internal white wear indicator layer.
- Test Probes: Cat III 1000V.
- Motor: 1100W with thermal cut-out.
- Grills: Black Nylon 15% Glass Filled.
- Cable Grommet: TPE 90A Shore.
- Body: PC-ABS Fire Retardant – spark finish.
- Hook: Polished 316 S/S that allows hands free operation.
- Product Code: LT240A15
M1120 NST Neutral Supply Tester Kit
Excluding GST 10%
LCD screen to display measurement results and messages.
CAT IV 600V instrument and lead set compliance.
IP54 moisture and dust ingress rating.
Compact hand held unit housed in a lightweight heavy-duty case
Uniquely self powered passive device.
Power is taken directly from the user’s connections.
3 LED indicators and an LCD screen for status and measurement information.
An audible alarm is fitted internally as a secondary indicator. To indicate a pass at the end of the measurement cycle or a measurement failure.