- ADP-SC/APC SC-APC Simplex Adapter
“Fluke ULD-410 ULTRASONIC LEAK DETECTOR” has been added to your cart. View cart
Previous product
Back to products
Fluke Networks ADP-SC/APC SC-APC Simplex Adapter
$57.00
Excluding GST 10%
Next product
Fluke Networks QuickClean-1.25-5P Quick Clean Cleaner 1.25 mm Fiber, LC and MU, 5 Pack
$1,204.00
Excluding GST 10%
Fluke Networks ADP-SC/APC SC-APC Simplex Adapter
$57.00Excluding GST 10%
- ADP-SC/APC SC-APC Simplex Adapter
Available on backorder
Category: Uncategorized
Related products
Fluke INDC8 – Insulated Heavy Duty Diagonal Cutter
$108.00
Excluding GST 10%
Product Features:
- Nominal length: 8 in., 200 mm
- Cuts hard materials including steel and piano wire
- Power joint and precision cutting edges
- German CMV steel
- Designed to block potentially hazardous voltages from reaching you
- Subjected to a 10,000 V dielectric strength test, protection protection works
- Certified to 1,000 V ac and 1,500 V dc by VDE, (independent third-party lab)
- Comply to international standards such as IEC 60900 and ASTM F1505
- Critical part of NFPA 70E, which requires personal protective equipment and insulated tools rated for electrical installation
- Critical protective component between you and unplanned incident
M1120 NST Neutral Supply Tester Kit
$750.00
Excluding GST 10%
LCD screen to display measurement results and messages.
CAT IV 600V instrument and lead set compliance.
IP54 moisture and dust ingress rating.
Compact hand held unit housed in a lightweight heavy-duty case
Uniquely self powered passive device.
Power is taken directly from the user’s connections.
3 LED indicators and an LCD screen for status and measurement information.
An audible alarm is fitted internally as a secondary indicator. To indicate a pass at the end of the measurement cycle or a measurement failure.
Fluke Amprobe ACD-14-PRO Dual Display 600 A TRMS Clamp Multimeter
$368.00
Excluding GST 10%
Product Features:
- Large LCD with dual display can show voltage and amps simultaneously
- True-RMS for accurate voltage measurements in noisy environments
- Low pass filter for current and voltage measurements on variable frequency drives
- Amp-Tip function for precise low current measurement down to 0.1 amp
- Ideal for HVAC applications with temperature, DC micro-amps and capacitance measurements
- Performs non-contact voltage detection (NCV)
- In-rush current measurement
- Audible continuity and diode test
- Data hold function
- Auto ranging instantly selects correct range
- Auto power off and low battery indicator
- Safety rated to CAT III 600 V
Fluke Amprobe TM-SWA CABLE AND SOFTWARE FOR TMD90 AND TMA10
$96.00
Excluding GST 10%
Amprobe TM-SWA Cable and Software for TMD90A and TMA10A
Fluke Amprobe UAT-620 UNDERGROUND UTILITY LOCATOR KIT W/CLAMP
$8,763.00
Excluding GST 10%
Product Features:
- Multiple tracing modes allow you to locate and trace energized and de-energized utilities in several applications
- Intuitive Transmitter automatically chooses correct locating function based on connected accessory and includes selectable 8/33 kHz frequencies
- Receiver’s high-contrast display allows for clear viewing in full sunlight and features automatic backlight for shaded and dark areas
- Rated CAT IV 600 V, ensuring safety when working with energized cables
- Semi-automatic gain control quickly detects tracing signal and allows precise adjustment of receiver sensitivity
- Accurate depth measurement to 20 ft
- Rugged, durable construction
- Water and dust resistant to IP54
- Drop proof to 3.28 ft (1 m)
- Signal Clamp induces signal without making electrical contact
- Ground fault locating with optional A-Frame accessory (AF-600)
- Comes as complete kit, ready for use
- Three testing modes:
- Passive power mode (50/60 Hz) – Tracing energized lines conducting current (no Transmitter necessary)
- Passive radio mode (RF) – Using surrounding radio waves to trace underground utilities (no Transmitter necessary)
- Active mode – Using UAT-600-T Transmitter
- Three active modes with UAT-600-T Transmitter:
- Induction – Transmitter will automatically start to radiate signal around it with internal antenna, used for tracing individual cables where there is no access to line to connect test leads or clamp
- Direct connection with test leads – Most reliable method to trace individual cable or pipe
- Clamp – Provides efficient and safe method of applying locate signal to cable, where it is not possible or safe to gain access to cable for making electrical contact
- Main applications:
- Locate energized 50/60 Hz cables carrying current
- Identify location of all metallic utilities, pipes* or cables (energized or de-energized)
- Trace individual pipes* or cables (energized or de-energized)
- *Tracing of non-metallic pipes and conduits is possible after inserting metal fish tape or cable
- Special applications:
- Two frequency options: 8 kHz and 33 kHz
- Locate non-metallic pipes and sewer lines
- Take depth and current measurements
- Measure voltage, resistance and output current
- Advanced locating with two people
- Locate ground faults with the AF-600 A-Frame accessory
Applications
- Commercial and Residential Construction Contractors
- Water, Gas and Electric Installation and Repair Crews
- Pipe Laying Contractors
- Cable TV and Telecommunication Companies
- Electricians and General Contractors
Fluke MP1-3R/1B – Magnetic Voltage Probes
$160.00
Excluding GST 10%
Fluke MP1-3R/1B Magnetic Voltage Probes, Three Red, One Black
Fluke LVD1A Volt Light
$69.00
Excluding GST 10%
- Built-in flashlight
- Detector glows blue when AC voltage is present
- Detector glows red when it is at the source
Fluke Amprobe AT-6030 Advanced Wire Tracer Kit
$2,206.00
Excluding GST 10%
Key features
- Work directly on an energized circuit without the need to take equipment offline
- Save time searching for energized and de-energized wires hidden behind walls, ceilings and floors
- Pinpoint wire location with the large color LCD Receiver screen featuring four unique modes
- Identify breakers and fuses, as well as the location of a break, open or short
- Non-Contact Voltage Detection utilizes passive tracing without the Transmitter to verify if a wire is energized
- Includes the CT-400 Signal Clamp accessory for inducing a tracing signal on the cable when there is no access to bare conductors