Show sidebar
Close

Fluke 700HPPK Pneumatic Test Pump Kit

  • Generate and adjust pneumatic pressures up to 21 MPa (3000 psi)
  • Rugged, portable and stable enough to go anywhere — on any surface
  • Reaches pressure in 20 seconds to full scale into a 30 cm3 volume
  • Detachable pressure adjustment system for adjusting pressure, connecting reference and test devices on bench and in the field, and isolating and venting pressure
  • Easily switch out reference gauges without requiring PTFE tape or tools
  • 2-meter (6.5-foot) pressure line and assorted pressure fittings enable a wide variety of possible connections
  • In-line filter and desiccant systems protect device from contamination from the DUT
Read more
Placeholder
Close

Fluke 6531, 6532 E-DWT Electronic Deadweight Tester Kits

  • No weights to load and unload, transport or send out for calibration
  • Provides real-time pressure indication with no need to know and correct for local gravity or ambient temperature
  • No piston-cylinder changes
  • No significant sensitivity to level or vibration
  • Able to set and read any pressure value exactly, no minimum increment limited by smallest available masses; perfect for applications that require setting a nominal pressure precisely on the device under test and measuring it, such as analog gauge calibration
  • Operates in any unit of measure, switching easily from one unit to the next
Read more
Close

Fluke 5640 Series Thermistor Standards Probes

  • Accuracy to ± 0.001 °C
  • Affordable system accuracy to ± 0.004 °C or better
  • NIST-traceable calibration included from manufacturer; accredited calibration from Fluke Calibration optional
Read more
Close

Fluke 5627A Precision Thermometer, RTD Temperature Probe

  • Vibration and shock resistant
  • NVLAP-accredited calibration included, lab code 200706-0
Read more
Close

Fluke 5626, 5628 Secondary Standard PRTs

  • Range to 661°C
  • Meets all ITS-90 requirements for resistance ratios
  • Rtp drift < 20 mK after 500 hours at 661°C
  • Calibrated accuracy of ± 0.006 °C at 0 °C
Read more
Close

Fluke 5624 Platinum Resistance Thermometer to 1000 °C

  • Temperature range of 0°C to 1000°C
  • Accuracy (includes short-term stability and calibration uncertainty) of ±0.05°C to 962°C
  • Long-term drift of 0.01°C at 0°C after 100 hours at 1000°C
  • Designed by Fluke Calibration’s primary standards design team
Read more
Placeholder
Close

Fluke 5623B Precision RTD Freezer Probe

  • Fully immersible probe assembly to –100°C
  • NVLAP-accredited calibration, lab code 200706-0, and ITS-90 coefficients included
  • Accuracy to ±0.05°C over the full range
Read more
Placeholder
Close

Fluke 5622 Fast Response Platinum Resistance Thermometers (PRTs)

  • Time constants as fast as 0.4 seconds
  • NVLAP-accredited calibration, lab code 200348-0
  • Small probe diameters ranging from 0.5 mm to 3.2 mm
Read more
Close

Fluke 5618B Small Diameter Industrial RTD

  • Small diameter sheath, 3.2mm (0.125 in)
  • Excellent stability
  • Includes ITS-90 coefficients
  • NVLAP-accredited calibrated from –200°C to 500°C, lab code 200706-0
Read more
Close

Fluke 5615 Secondary Reference Temperature Standards

  • Affordable wide-range accuracy
  • Calibrated accuracy ± 0.012 °C at 0 °C
  • Reference-grade platinum sensing element
  • NVLAP-accredited calibration included, lab code 200706-0
Read more
Close

Fluke 5610, 5611, 5611T, 5665 Temperature Probes, Reference Thermistor Probes

  • Temperature probes with short-term accuracy to ± 0.01 °C; one-year drift < ± 0.01 °C
  • Accredited NVLAP calibration optional
  • Flexible PTFE and silicone coated fast-response models
  • Rugged polished stainless steel sheaths
Read more
Close

Fluke 5606 Full Immersion PRT

  • 5606: -200 °C to 160 °C
  • Calibration accuracy of ± 0.05 °C
  • Transition junction and lead wires can withstand full PRT temperature range
  • Unique probe seal of 5606 prevents ingress of moisture
  • NVLAP-accredited calibration
Read more