Fluke 2456 Piston Gauge Monitor
- Automates piston gauge calibrations
- Monitors critical piston gauge parameters
- Dual channel capability for cross float calibrations
- WinPrompt software is Windows based
- Use WinPrompt alone or in combination with Model 2456 PGM
- Export data to create customized calibration reports and certificates
Fluke PG7601 Piston Gauge
- State-of-the-art primary pressure standards for the lowest uncertainty levels
- Unified solution from vacuum to 500 MPa
- Outputs fully validated reference pressures in real time
- Intuitive local operator interface
- Manual, semi-automated and fully automated configurations
Fluke 2468A – Pitot/Static Primary Standard
- Pressure range: 0.4 to 103 inHg
- Optional range: 3.4 to 400 inHg
- Accuracy to ±0.5 feet, 0.003 knots
- Ideal for calibrating RVSM compliant test sets
- Absolute and gauge calibration for Ps, Pt & Qc ranges
- Calibrate in a variety of units
Fluke 2465A Gas Piston Gauge
- Pressure ranges from 1.4 kPa to 7 MPa (0.2 to 1000 psi)
- Accuracy to 0.0010% (10 ppm) of reading for pressures to 700 kPa (100 psi)
- Accuracy to 0.0027% (27 ppm) of reading for pressures
greater than 700 kPa to 7 MPa (100 psi to 1000 psi) - Precision better than 3 ppm
- Stability better than 3 ppm per year
- Resolution 0.0001% (1 ppm) or 1 mg
- Gauge, absolute, vacuum and low pressure modes
Fluke 2456-LEM Laboratory Environment Monitor
- Communicates via RS-232 or RS-485
- Includes software to display all parameters in addition to data logging and calibration
- Precision to 0.1 °C, 0.04 inHg (1.3 mbar) and 3 % RH
- Ideal for calibration labs, clean rooms, storage facilities or use with Ruska piston gauges
- Replaces mechanical strip chart recorders
Fluke 1620A Digital Thermometer-Hygrometer
- Superior accuracy
- Network enabled
- Powerful logging and analysis tools
- Two interchangeable calibrated sensors
- Huge memory
- Upgraded software
Fluke 5128A RHapid-Cal® Humidity Generator
- Best-in-class system accuracy for dependable humidity probe calibration
- Rapid humidity and temperature stabilization time for high calibration throughput
- Supports on-site, multi-point calibration of humidity probes
- Versatile design accommodates a large workload
- Compact size and lightweight for easy transport
- ISO 17025 accredited system calibration included standard
- Easy to maintain
Fluke 9100S, 9102S Handheld Dry-Wells
- Smallest dry-wells in the world
- Ranges from –10°C to 375°C
- Accuracy to ±0.25°C, stability of ±0.05°C at 0°C
- RS-232 interface
Fluke 6102, 7102, 7103 Micro-Bath Thermometer Calibrators
- World’s smallest portable calibration baths
- Calibrates sensors of any size or shape
- Stability to ±0.015 °C
- Ranges from –30 °C to 200 °C
Fluke 9170, 9171, 9172, & 9173 Metrology Well Calibrators
- Best-performing industrial heat sources (accuracy, stability, uniformity) in the world
- Immersion depth to 203 mm (8 in)
- Optional ITS-90 reference input reads PRTs to ±0.006 °C
- Temperature range from –45 °C to 700 °C
Fluke 9190A Ultra-Cool Field Metrology Well
Wide temperature range
–95 °C to 140 °C
Excellent accuracy
Accuracy using built-in reference thermometer readout: ± 0.05 °C full range
Display accuracy: ± 0.2 °C full range
Best-in-class stability
± 0.015 °C full range
Fast cooling time
23 °C to –90 °C: 80 minutes
23 °C to –95 °C: 90 minutes
140 °C to 23 °C: 60 minutes
Fluke 9142, 9143, 9144 Field Metrology Wells
- Lightweight, portable, and fast
- Cool to –25 °C in 15 minutes and heat to 660°C in 15 minutes
- Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
- True reference thermometry with accuracy to ±0.01 °C
- On-board automation and documentation
- Metrology performance in accuracy, stability, uniformity, and loading