Fluke 525B Temperature/Pressure Calibrator

  • Simulates and measures all ANSI thermocouples, as well as L and U types, and provides cold junction compensation to enable calibration of a wide variety of thermocouple instrumentation.
  • Direct input for storage of ITS-90 RTD constants.
  • RTD source uncertainties to 0.03° C
  • Extend pressure measurement range with any Fluke 750P and 700P Series Pressure Modules
  • Converts easily to any pressure unit directly from the front panel or through remote communications.
  • Sources dc voltage and current for multifunction workload coverage, enabling calibration of data loggers, strip chart recorders, multimeters, and other industrial instruments.
  • Supports automation using MET/CAL® Plus Calibration Management Software or custom automated programs with standard RS-232-C and GPIB interface.
  • Eight user programmable setpoints allow quick recall of values for Zero, Span and linearity checks during calibration. Programmable setpoint dwell times for automated calibration and troubleshooting.
  • Programmable setpoint dwell times for automated calibration and troubleshooting.
  • Selectable internal or external CJC (cold junction compensation) provides you with the ability to make exacting thermocouple measurements using remote junctions.
  • Easy five-way binding posts for low-loss convenient hookup. Banana plug, screw terminal, spade lug, wraparound terminal, wire pass-through terminal.
  • NIST-traceable calibration with data is included
Close

Fluke 5322A Electrical Safety Tester Calibrator

The 5322A calibrates a broad range of equipment, including:

  • Hipot testers
  • Insulation resistance testers (megohm-meters) including older analog testers
  • Loop/line impedance testers
  • Continuity testers
  • Earth resistance testers
  • Ground bond testers
  • Leakage current testers
  • Circuit breaker testers (RCD/GFCI)
  • Multifunction installation testers
  • Portable appliance testers (PATs)
Placeholder
Close

Fluke 5430 Standard AC/DC Resistors

  • Long-term stability better than 2 ppm/year (< 1 ppm typical)
  • Traceable AC and DC calibrations available
  • National lab design proven for more than 25 years
Close

Fluke 5502A Multi-Product Calibrator

Key Features :

  • Calibrates a wide variety of electrical test equipment
  • Robust protection circuits prevent costly damage from operator error
  • Ergonomically designed carrying handles make the 5502A easy to transport
  • Rugged carrying case with built-in handles and wheels and removable front/rear access doors for in-situ calibration in almost any environment
  • Current output that extends to 120 A when paired with the 52120A Transconductance Amplifier
  • Remarkably affordable
Close

Fluke 5502A Multi-Product Calibrator

  • Handheld and bench meters (analog and digital) to 4.5 digits
  • Current clamps and clamp meters
  • Panel meters
  • Electronic thermometers
  • Chart recorders
  • Oscilloscope recorders
  • XY recorders
  • Data loggers
Close

Fluke 5522A Multi-Product Calibrator

  • Calibrates a wide variety of electrical test equipment
  • Robust protection circuits prevent costly damage from operator error
  • Resistance calibrator, voltage calibrator, current calibrator and more
  • Redesigned carrying handles make the 5522A easy to transport
  • Rugged optional carrying case with built-in handles and wheels and removable front/rear access doors for in-situ calibration in almost any environment
  • Remarkably affordable
Close

Fluke 5606 Full Immersion PRT

  • 5606: -200 °C to 160 °C
  • Calibration accuracy of ± 0.05 °C
  • Transition junction and lead wires can withstand full PRT temperature range
  • Unique probe seal of 5606 prevents ingress of moisture
  • NVLAP-accredited calibration
Close

Fluke 5610, 5611, 5611T, 5665 Temperature Probes, Reference Thermistor Probes

  • Temperature probes with short-term accuracy to ± 0.01 °C; one-year drift < ± 0.01 °C
  • Accredited NVLAP calibration optional
  • Flexible PTFE and silicone coated fast-response models
  • Rugged polished stainless steel sheaths
Close

Fluke 5615 Secondary Reference Temperature Standards

  • Affordable wide-range accuracy
  • Calibrated accuracy ± 0.012 °C at 0 °C
  • Reference-grade platinum sensing element
  • NVLAP-accredited calibration included, lab code 200706-0