Fluke PM9092/001 50 Ohm Coaxial BNC cable set
Fluke PM9092/001 Offers
Each set consists of three black cables with colored BNC male connectors (red, gray and black) for easy identification
- Cable length is 0.5 m (1.6 ft).
- Maximum Signal Voltage: 300 V rms
- Maximum Voltage to Ground: 600 V rms. CAT III per IEC 61010-031
- Fluke BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
Fluke PM9093 Male BNC to Dual Female BNC Adapter
Features
- Male BNC to dual female BNC T-piece, set consists of two adapters
- Maximum Signal Voltage: 300 V rms
- Maximum Voltage to Ground: 600 V rms, CAT III per IEC 61010-031
Fluke PM9096/201
Secondary pick-up for the 97AUTO, 1000:1.
Fluke PPA9159-CAL Fine Increment Weight for kPa, mPa, bar or kgf/cm2 Weight Sets
What’s included with the Fluke PPA9159-CAL
- Fluke PPA9159-CAL Fine Increment Weight for kPa, mPa, bar or kgf/cm2 Weight Sets
Fluke PPA9608-CAL Incremental Weights for psi Weight Sets
What’s included with the Fluke PPA9608-CAL
- Fluke PPA9608-CAL Incremental Weights for psi Weight Sets
Fluke PPCH Automated Pressure Controller / Calibrator
- Hydraulic pressure controller to 200 MPa (30,000 psi)
- High precision control
- AutoRange feature
- For liquid pressures up to 30,000 psi (200 MPa)
- One or two Q-RPTs in each controller
- Supports external reference pressure transducers
- FLASH memory for simple and free embedded software upgrades via Fluke Calibration web-site
Fluke PQ-MARKER Cable Marker Set
For use with the PQ400 Power Quality Window.
Fluke PQ400 Power Quality Window with cables, cable ties & markers
Features
- Permanently connected voltage and current sensors located inside the electrical panel allow you to make power quality and energy measurements using the external access points without opening the panel door, reducing operator risk
- Voltage and current connections for three-phase voltages, neutral and ground cover most measurement scenarios
- Automatic probe detection for 1740 and 1730 series power quality and energy loggers and compatible clamps, eliminates the need to open cabinet to check the clamp model
- Full 360° rotation allows the window to be oriented in any direction
- Simple installation using a step drill bit and electro-hydraulic hole punch (114.3 mm, 4.5″ diameter)
- CAT IV, 600 V and CATIII 1000 V rating according to IEC61010-2-30
- Compatibility with standard 4 mm shrouded safety-socket voltage test leads makes it easier to make voltage connections, and increases safety by reducing the risk of accidentally touching live electrical components
Fluke PressCal Pressure Calculation/Calibration Software
Fluke PRESSCAL Offers
Features
- Menu-driven, easy-to-use software
- Maintain multiple deadweight tester files
- Pressure-equivalent calculations with all corrections applied
- Pre-loaded calibration data
- 12 pressure units
- Windows 95 or higher running on a 486 PC (minimum)
Fluke Probe Support Hardware
- 2 V-bases
- 1 29-inch stainless steel rod
- 2 23-inch rods
- 5 bossheads
- 2 micro-clamps
- 1 medium clamp
Fluke PRV240 Proving Unit, 240V
Fluke PRV240 Offers
Reduces the risk of shock and arc flash by removing unnecessary exposure to a potentially hazardous electrical environment while verifying the functionality of test tools before and after absence or presence of voltage is checked.
Features
- Sources both AC and DC steady-state voltage – supplies 240 V DC/AC
- A single LED indicates functionality, making this unit a simple-to-use solution for verification of your test tool
- Compatible with both high impedance or low impedance multimeters, clamp meters or two pole testers
- Voltage is sourced through recessed contacts that are activated when tested probes are inserted to avoid accidental contact
- Long battery life – 5,000 tests per set of four AA batteries
Test Before Touch
Provides a safe method to verify that your electrical test tool is operating properly before you conduct further tests. The concept of “Test Before Touch” (TBT) or three point test method involves testing your meter against a known live source before and after the actual measurement. This sequence verifies that your test tool is operating properly during the actual measurement.
Designed for safety and compliance
Safe and easy method for verifying proper operation of your test tool before attempting to test for either an energized source or a de-energized source without the need for cumbersome PPE, or in cases where no known voltage source is available. Your environment may still require minimal PPE such as hard, safety glasses or earplugs when using a proving unit.