Fluke 80i-110s AC/DC Current Clamp
Features
- 10 or 100A AC/DC nominal current range
- Continuous current range
- 0.1 to 10A AC/DC (100mV/A output)
- 1 to 100A AC/DC (10mV/A output)
- ±3% of reading +50mA (100mV/A, 50mA to 10A)
- ±4% of reading +50mA (10mV/A, 50mA to 40A)
- ±12% of reading +50mA (40 to 80A)
- ±15% of reading (80 to 100A)
- Maximum non-destructive current of 140A (2kHz)
- Lowest measurable current of 0.1A
- 100kHz useable frequency
- CAT II 600V & CAT III 300V
- 1-year warranty
Fluke i1010 AC/DC Current Clamp
Features
- Hall sensor with 1mV/A output level
- 2% + 0.5A accuracy
- 1000A maximum non-destructive current
- 10kHz useable frequency
- Zero error adjustment
- Shrouded banana plug connector
- Optional kit includes carrying case
- CAT III 600V Safety rating
Fluke i410 AC/DC Current Clamp
Features
- Battery-powered Hall-effect probe measures 1 to 400 A
- 1 mV/Amp output guarantees easy reading on your meter
- Take accurate current readings without breaking the circuit
- Maximum conductor Ø 32 mm
- CAT III 600 V safety rating
Fluke i3000s AC Current Clamp
Features
- For measurement on power distribution systems
- Current ranges with 2% + 2A basic accuracy
- 1 to 30A (10mV/A output)
- 1 to 300A (1mV/A output)
- 1 to 3000A (0.1mV/A output)
- 4000A maximum non-destructive current
- 10Hz to 100kHz usable frequency
- 64mm maximum conductor diameter
- CAT III 600V safety rating
- 1-year warranty
Fluke i200 AC Current Clamp
-
Fluke I200 Offers
Features
- Companion to a DMM for measuring up to 200 A AC
- 1 mA per Amp output guarantees easy reading on you meter
- Take accurate current readings without breaking the circuit
- Max. conductor Ø 0.8″ (20 mm)
- CAT III 600 V safety rating
Fluke i6000s Flex AC Current Clamp
Features
- AC RMS current ranges with ±1% accuracy
- 60A (50mV/A output)
- 600A (5mV/A output)
- 6000A (0.5mV/A output)
- 10Hz to 50kHz frequency
- 100kΩ minimum load impedance
- CAT III 600V safety rating
Fluke I1000s AC Current Clamp
Features
- 10, 100, & 1000A nominal AC current ranges
- Continuous current ranges
- 0.1 to 10A (100mV/A output)
- 0.1 to 100A (10mV/A output)
- 1 to 1000A (1mV/A output)
- 1% +1A (48 to 65Hz) %reading + floorspec accuracy
- 2000A maximum non-destructive current
- CAT III 600V & CAT IV 300V
- 1-year warranty
Description
- Allows accurate measurement of currents from 100 mA to 1000 A rms, 5 Hz to 100 kHz without breaking into the circuit
- A passive filter eliminates noise and ring on rapidly rising di/dt waveform, ensuring accurate screen displays
- Connects directly to an oscilloscope through a reinforced coaxial cable and an insulated BNC connector
- Can be used with multimeters with optional PM9081/001 BNC/Banana adapter (sold separately)
Fluke i400s AC Current Clamp
Features
- Take current readings without breaking the circuit
- 0.5 to 40A (10mV/A output)
- 2% + 0.015A accuracy
- 5 to 400A (1mV/A output)
- 2% + 0.04A accuracy
- 32mm maximum conductor diameter
- Soft non-slippery overmold handle
- 1-year warranty
Compatible with
- Fluke 114 Electrical Multimeter
- Fluke 117 Electrician’s Multimeter with Non-Contact Voltage
- Fluke 434-II and 435-II Power Quality and Energy Analyzers
- Fluke 438-II Power Quality Analyzer and Motor Analyzer
- Fluke PQ400 Electrical Measurement Window
Fluke i5s AC Current Clamp
Product Features:
- Current range: 10mA to 5A AC
- Frequency range: 40 Hz to 5 kHz
- Safety rating(s): CAT III 600V (for insulated conductors only)
- Compact shape makes transporting and storing convenient
- Takes accurate readings without breaking circuits
Fluke i2000 Flex AC Current Clamp
Features
- AC RMS current ranges with ±1% accuracy
- 20A (100mV/A output)
- 200A (10mV/A output)
- 2000A (1mV/A output)
- 10Hz to 20kHz frequency
- 100kΩ minimum load impedance
- 178mm maximum conductor diameter
- CAT III 600V safety rating
Fluke i400 AC Current Clamp
Features
- Take current readings without breaking the circuit
- 1 to 400A (1mA/A output)
- 2% + 0.06A accuracy
- 1000A maximum non-destructive current
- 5Hz to 20kHz frequency
- 32mm maximum conductor diameter
- Soft non-slippery overmold handle
- 1-year warranty
Fluke i3000s Flex AC Current Clamp
Features
- AC RMS current ranges with ±1% accuracy
- 1 to 30A (100mV/A output)
- 1 to 300A (10mV/A output)
- 1 to 3000A (1mV/A output)
- 10Hz to 50kHz frequency
- 100kΩ minimum load impedance
- CAT III 600V safety rating